23.10.2014 Views

BlueLine Steam BlueLine Steam Technical ... - Ulrich Models

BlueLine Steam BlueLine Steam Technical ... - Ulrich Models

BlueLine Steam BlueLine Steam Technical ... - Ulrich Models

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>BlueLine</strong> <strong>Steam</strong><br />

<strong>Technical</strong> Reference Manual<br />

Release 1.00<br />

Page 1 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


INTRODUCTION<br />

The M1 sound unit is a multi-function DCC decoder that supports the<br />

following:<br />

DCC Characteristics<br />

• 14 bit addressing<br />

• 7 bit addressing (1-127)<br />

• Enhanced Lighting Control<br />

• Advanced Sound Support<br />

• Consist Support<br />

• 14, 28 and 128 speed steps<br />

• Support for F0—F12 including remapping<br />

• Operations mode support for all CV settings<br />

• Configuration Variable Access Acknowledgement in Service mode<br />

• Direct Mode support in Service Mode including Write and Verify<br />

DC characteristics<br />

• DCMaster uses Direct Mode for CV Programming<br />

• All CV’s programmable<br />

• Enhanced Lighting Control<br />

• Advanced Sound Support<br />

• Consist Support<br />

• Enhanced Motor Control<br />

• Selectable DCMaster AUX Control<br />

Page 2 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SYSTEM CVs<br />

CV1<br />

Primary Address<br />

Description<br />

The Decoders Primary Address is Stored Here<br />

Values<br />

Bits 0-6 contain an address with a value between 1 and 127<br />

Initial Value<br />

3 (Engine 3)<br />

Related CVs<br />

CV29 Bit 5<br />

CV17, CV18, CV19, CV20<br />

Bit 7 Bit 0<br />

0 A6 A5 A4 A3 A2 A1 A0<br />

The decoder responds to all valid commands if the address matches<br />

the value in CV1 and CV29 Bit 5 is set to 0.<br />

Programming CV1 will program CV19 (Consists Address) to zero<br />

and programs CV29 Bit 5 to 0 (Extended Addressing Off).<br />

Page 3 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SYSTEM CVs<br />

CV7<br />

Manufacturer Version Number<br />

Description<br />

The Decoders Read Only Type/Revision is Stored Here<br />

Values<br />

Initial Value<br />

Related CVs<br />

None<br />

Bit 7 Bit 0<br />

D7 D6 D5 D4 D3 D2 D1 D0<br />

This value cannot be modified.<br />

000xxxxx = Diesel and xxxxx is the revision.<br />

001xxxxx = <strong>Steam</strong> and xxxxx is the revision.<br />

Page 4 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SYSTEM CVs<br />

CV8<br />

Manufacturer ID<br />

Description<br />

The Decoders NMRA Assigned Number is Stored Here. Broadway<br />

Limited is assigned ID 38.<br />

Values<br />

Initial Value<br />

38<br />

Related CVs<br />

None<br />

Bit 7 Bit 0<br />

0 0 1 0 0 1 1 0<br />

Writing an 8 to this location will reset all CVs back to their original<br />

manufactured values. This value itself cannot be modified.<br />

Page 5 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SYSTEM CVs<br />

CV15<br />

Unlock ID Code<br />

Description<br />

The Number is the Unlock ID<br />

Values<br />

0-7<br />

Initial Value<br />

0<br />

Related CVs<br />

None<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 0<br />

Factory new units have the unlock id code and the lock id number set<br />

to zero, allowing normal programming of all CV’s. Users wishing to<br />

lock this decoder may start by programming CV16 with a<br />

recommended value of 2. Now, unlock the decoder for CV updates<br />

by writing 2 to CV15. Once all programming is completed, write a<br />

value of 0 to CV15. Now the decoder is locked. Please note once the<br />

decoder is locked, no CV’s other than CV1 or CV15 may be read or<br />

changed. The factory reset is also disabled.<br />

Page 6 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SYSTEM CVs<br />

CV16<br />

Lock ID Number<br />

Description<br />

This Number Identifies this Single Decoder.<br />

Values<br />

0-7<br />

Initial Value<br />

0<br />

Related CVs<br />

None<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 0<br />

This value may only be changed when CV15 equals CV16. CV15<br />

may always be read. The following definitions may be used when<br />

programming this number:<br />

Lock Disabled 0<br />

Motor Decoder 1<br />

Sound Decoder 2<br />

Function Decoder 3<br />

If this feature is use, the recommendation is to program a 2 for value.<br />

Please note once the decoder is locked, no CV’s other than CV1 or<br />

CV15 may be read or changed. The factory reset is also disabled.<br />

Page 7 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV17 and CV18<br />

Extended Address<br />

SYSTEM CVs<br />

Description<br />

This Value Contains the Decoders Extended Address and is Valid<br />

Only if CV29 Bit 5 is 1<br />

Values<br />

Values From 0 to 10239 are Valid<br />

Initial Value<br />

1100 0000 1000 0000 (Engine 128)<br />

Related CVs<br />

CV29 Bit 5<br />

Bit 15 Bit 8<br />

1 1 A13 A12 A11 A10 A9 A8<br />

CV17 Extended Address MSB<br />

Bit 7 Bit 0<br />

A7 A6 A5 A4 A3 A2 A1 A0<br />

CV18 Extended Address LSB<br />

CV17 Valid Values are 1100 0000 thru 1110 0111<br />

CV18 Valid Values are 0000 0000 thru 0000 0000<br />

Page 8 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SYSTEM CVs<br />

CV19<br />

Consist Address<br />

Description<br />

The Decoders Consist Address is Stored Here<br />

Values<br />

0-255<br />

Initial Value<br />

0<br />

Related CVs<br />

CV21, CV22, CV224, CV229<br />

Bit 7 Bit 0<br />

Dir A6 A5 A4 A3 A2 A1 A0<br />

Consist valid address are 1-127 or A6-A0 where a value of 0 breaks<br />

the consist and all received consist commands are ignored. The Dir<br />

bit selects normal or reverse directional lighting. If Dir=0 than normal<br />

directional lighting is selected. If Dir=1 than reverse directional<br />

lighting is selected. Reverse directional lighting is useful when the<br />

engine is oriented backwards in the consist.<br />

See Consist, a technical discussion.<br />

Page 9 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV21<br />

Consist Functions Type 0<br />

SYSTEM CVs<br />

Description<br />

Determines Which Functions (F1-F8) are Allowed in the Consist<br />

Values<br />

0-255<br />

Initial Value<br />

255<br />

Related CVs<br />

CV19, CV22, CV223, CV229<br />

Bit 7 Bit 0<br />

F8 F7 F6 F5 F4 F3 F2 F1<br />

The decoder responds to all functions that have a “1” set in this CV<br />

once a consist is configured. A consist is configured by CV19<br />

programmed to a value from 1-127. A value of 0 breaks the consist.<br />

See CV19. This CV is used to configure the engine for a front, middle<br />

or end in the consist.<br />

An example for consist number 60:<br />

CV19=60 DCC DC<br />

Front Engine CV21=255 CV22=255 CV229=133 CV223=133<br />

Middle Engine CV21=128 CV22=5 CV229=0 CV223=0<br />

Rear engine CV21=128 CV22=5 CV229=2 CV223=2<br />

See Consist, a technical discussion.<br />

Page 10 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Bit 4:<br />

Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

0=F8 Disabled<br />

1=F8 Enabled<br />

0=F7 Disabled<br />

1=F7 Enabled<br />

0=F6 Disabled<br />

1=F6 Enabled<br />

0=F5 Disabled<br />

1=F5 Enabled<br />

0=F4 Disabled<br />

1=F4 Enabled<br />

0=F3 Disabled<br />

1=F3 Enabled<br />

0=F2 Disabled<br />

1=F2 Enabled<br />

0=F1 Disabled<br />

1=F1 Enabled<br />

Page 11 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV22<br />

Consist Functions Type 1<br />

SYSTEM CVs<br />

Description<br />

Determines Which Functions (F0; F9-F12) are Allowed in the Consist<br />

Values<br />

0-255<br />

Initial Value<br />

255<br />

Related CVs<br />

CV19, CV21, CV223, CV229<br />

Bit 7 Bit 0<br />

nu nu F12 F11 F10 F9 nu F0<br />

The decoder responds to all functions that have a “1” set in this CV<br />

once a consist is configured. A consist is configured by CV19<br />

programmed to a value from 1-127. A value of 0 breaks the consist.<br />

See CV19. This CV is used to configure the engine for a front, middle<br />

or end in the consist.<br />

An example for consist number 60:<br />

CV19=60 DCC DC<br />

Front Engine CV21=255 CV22=255 CV229=133 CV223=133<br />

Middle Engine CV21=128 CV22=5 CV229=0 CV223=0<br />

Rear engine CV21=128 CV22=5 CV229=2 CV223=2<br />

See Consist, a technical discussion.<br />

Page 12 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Bit 4:<br />

Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

not used<br />

not used<br />

0=F12 Disabled<br />

1=F12 Enabled<br />

0=F11 Disabled<br />

1=F11 Enabled<br />

0=F10 Disabled<br />

1=F10 Enabled<br />

0=F9 Disabled<br />

1=F9 Enabled<br />

not used<br />

0=F0 Disabled<br />

1=F0 Enabled<br />

Page 13 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SYSTEM CVs<br />

CV29<br />

Configuration Bits<br />

Description<br />

Decoder Configuration Feature Bits<br />

Values<br />

0, 1, 2, 3, 32, 33, 34 or 35<br />

Initial Value<br />

2 (Primary Address)<br />

Related CVs<br />

CV1, CV17, CV18<br />

Bit 7 Bit 0<br />

0 0 EA 0 0 0 1 0<br />

Bit 5:<br />

Bit 1:<br />

Bit 0:<br />

EA (Extended Address Mode Enable)<br />

0 = Decoder Responds to Primary Address CV1<br />

1 = Decoder Responds to Extended Address CV17, CV18<br />

0 = 14 speed step if controller set for 14 bits<br />

1 = 28 speed step if controller set for 28 bits<br />

0 = normal lighting for front and rear lights<br />

1 = reverse lighting for front and rear lights<br />

Value of 32 will cause Bit 5 to become 1<br />

Page 14 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


FUNCTION CVs<br />

CV33<br />

F0(f) Output Function Definition<br />

Description<br />

Selects Which Function(s) F0 Activates<br />

Values<br />

0 to 255<br />

Initial Value<br />

1 (Front Lamp)<br />

Related CVs<br />

CV33—CV46<br />

Bit 7 Bit 0<br />

Blow/C+ Air Couple Bell Horn Whistle RL FL<br />

Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Bit 4:<br />

Blow Down/Increase Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Blow Down Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Increased<br />

Air Pump Sound Effects<br />

0 = Not Affected by F0<br />

1 = Air Pump Sound Activated/Deactivated by F0<br />

Coupler Sound Effects<br />

0 = Not Affected by F0<br />

1 = Coupler Sound Activated by F0 if Engine Moving<br />

Uncouple Armed if Engine Stopped<br />

Bell Sound Effects<br />

0 = Not Affected by F0<br />

1 = Bell Activated by F0<br />

Page 15 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

Horn Sound Effects (If Model Has This Effect)<br />

0 = Not Affected by F0<br />

1 = Horn Activated by F0<br />

Whistle Sound Effects<br />

0 = Not Affected by F0<br />

1 = Whistle Activated by F0<br />

Rear Light Visual Effects<br />

0 = Not Affected by F0<br />

1 = Rear Light Visual Effect Activated by F0<br />

Front Light Visual Effects<br />

0 = Not Affected by F0<br />

1 = Front Light Visual Effect Activated by F0<br />

Page 16 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


FUNCTION CVs<br />

CV34<br />

F0(r) Output Function Definition<br />

Description<br />

Selects Which Function(s) F0 Activates<br />

Values<br />

0 to 255<br />

Initial Value<br />

2 (Rear Lamp)<br />

Related CVs<br />

CV33—CV46<br />

Bit 7 Bit 0<br />

Blow/C+ Air Couple Bell Horn Whistle RL FL<br />

Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Bit 4:<br />

Blow Down/Increase Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Blow Down Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Increased<br />

Air Pump Sound Effects<br />

0 = Not Affected by F0<br />

1 = Air Pump Sound Activated/Deactivated by F0<br />

Coupler Sound Effects<br />

0 = Not Affected by F0<br />

1 = Coupler Sound Activated by F0 if Engine Moving<br />

Uncouple Armed if Engine Stopped<br />

Bell Sound Effects<br />

0 = Not Affected by F0<br />

1 = Bell Activated by F0<br />

Page 17 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

Horn Sound Effects (If Model Has This Effect)<br />

0 = Not Affected by F0<br />

1 = Horn Activated by F0<br />

Whistle Sound Effects<br />

0 = Not Affected by F0<br />

1 = Whistle Activated by F0<br />

Rear Light Visual Effects<br />

0 = Not Affected by F0<br />

1 = Rear Light Visual Effect Activated by F0<br />

Front Light Visual Effects<br />

0 = Not Affected by F0<br />

1 = Front Light Visual Effect Activated by F0<br />

Page 18 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV35<br />

F1 Output Function Definition<br />

FUNCTION CVs<br />

Description<br />

Selects Which Function(s) F1 Activates<br />

Values<br />

0 to 255<br />

Initial Value<br />

16 (Bell)<br />

Related CVs<br />

CV33—CV46<br />

Bit 7 Bit 0<br />

Blow/C+ Air Couple Bell Horn Whistle RL FL<br />

Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Bit 4:<br />

Blow Down/Increase Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Blow Down Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Increased<br />

Air Pump Sound Effects<br />

0 = Not Affected by F0<br />

1 = Air Pump Sound Activated/Deactivated by F0<br />

Coupler Sound Effects<br />

0 = Not Affected by F0<br />

1 = Coupler Sound Activated by F0 if Engine Moving<br />

Uncouple Armed if Engine Stopped<br />

Bell Sound Effects<br />

0 = Not Affected by F0<br />

1 = Bell Activated by F0<br />

Page 19 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

Horn Sound Effects (If Model Has This Effect)<br />

0 = Not Affected by F0<br />

1 = Horn Activated by F0<br />

Whistle Sound Effects<br />

0 = Not Affected by F0<br />

1 = Whistle Activated by F0<br />

Rear Light Visual Effects<br />

0 = Not Affected by F0<br />

1 = Rear Light Visual Effect Activated by F0<br />

Front Light Visual Effects<br />

0 = Not Affected by F0<br />

1 = Front Light Visual Effect Activated by F0<br />

Page 20 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV36<br />

F2 Output Function Definition<br />

FUNCTION CVs<br />

Description<br />

Selects Which Function(s) F2 Activates<br />

Values<br />

0 to 255<br />

Initial Value<br />

4(Whistle)<br />

Related CVs<br />

CV33—CV46<br />

Bit 7 Bit 0<br />

Blow/C+ Air Couple Bell Horn Whistle RL FL<br />

Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Bit 4:<br />

Blow Down/Increase Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Blow Down Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Increased<br />

Air Pump Sound Effects<br />

0 = Not Affected by F0<br />

1 = Air Pump Sound Activated/Deactivated by F0<br />

Coupler Sound Effects<br />

0 = Not Affected by F0<br />

1 = Coupler Sound Activated by F0 if Engine Moving<br />

Uncouple Armed if Engine Stopped<br />

Bell Sound Effects<br />

0 = Not Affected by F0<br />

1 = Bell Activated by F0<br />

Page 21 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

Horn Sound Effects (If Model Has This Effect)<br />

0 = Not Affected by F0<br />

1 = Horn Activated by F0<br />

Whistle Sound Effects<br />

0 = Not Affected by F0<br />

1 = Whistle Activated by F0<br />

Rear Light Visual Effects<br />

0 = Not Affected by F0<br />

1 = Rear Light Visual Effect Activated by F0<br />

Front Light Visual Effects<br />

0 = Not Affected by F0<br />

1 = Front Light Visual Effect Activated by F0<br />

Page 22 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV37<br />

F3 Output Function Definition<br />

FUNCTION CVs<br />

Description<br />

Selects Which Function(s) F3 Activates<br />

Values<br />

0 to 255<br />

Initial Value<br />

32 (Couple/Uncouple)<br />

Related CVs<br />

CV33—CV46<br />

Bit 7 Bit 0<br />

Blow/C+ Air Couple Bell Horn Whistle RL FL<br />

Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Bit 4:<br />

Blow Down/Increase Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Blow Down Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Increased<br />

Air Pump Sound Effects<br />

0 = Not Affected by F0<br />

1 = Air Pump Sound Activated/Deactivated by F0<br />

Coupler Sound Effects<br />

0 = Not Affected by F0<br />

1 = Coupler Sound Activated by F0 if Engine Moving<br />

Uncouple Armed if Engine Stopped<br />

Bell Sound Effects<br />

0 = Not Affected by F0<br />

1 = Bell Activated by F0<br />

Page 23 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

Horn Sound Effects (If Model Has This Effect)<br />

0 = Not Affected by F0<br />

1 = Horn Activated by F0<br />

Whistle Sound Effects<br />

0 = Not Affected by F0<br />

1 = Whistle Activated by F0<br />

Rear Light Visual Effects<br />

0 = Not Affected by F0<br />

1 = Rear Light Visual Effect Activated by F0<br />

Front Light Visual Effects<br />

0 = Not Affected by F0<br />

1 = Front Light Visual Effect Activated by F0<br />

Page 24 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV38<br />

F4 Output Function Definition<br />

FUNCTION CVs<br />

Description<br />

Selects Which Function(s) F4 Activates<br />

Values<br />

0 to 255<br />

Initial Value<br />

8 (Air Pump)<br />

Related CVs<br />

CV33—CV46<br />

Bit 7 Bit 0<br />

Volume L1 Water/C- Blow/C+ Air Couple Bell Horn<br />

Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Volume Audio Effects<br />

0 = Not Affected by F4<br />

1 = Volume Increases or Decreases on a Double Press<br />

Volume Mutes on a Single Press<br />

Light One Visual Effects<br />

0 = Not Affected by F4<br />

1 = Visual Light One Activated<br />

Water Fill/Decrease Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Water Fill Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Decreased<br />

Page 25 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 4:<br />

Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

Blow Down/Increase Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Blow Down Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Increased<br />

Air Pump Sound Effects<br />

0 = Not Affected by F0<br />

1 = Air Pump Sound Activated/Deactivated by F0<br />

Coupler Sound Effects<br />

0 = Not Affected by F0<br />

1 = Coupler Sound Activated by F0 if Engine Moving<br />

Uncouple Armed if Engine Stopped<br />

Bell Sound Effects<br />

0 = Not Affected by F4<br />

1 = Bell Activated by F4<br />

Horn Sound Effects (If Model Has This Effect)<br />

0 = Not Affected by F4<br />

1 = Horn Activated by F4<br />

Page 26 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV39<br />

F5 Output Function Definition<br />

FUNCTION CVs<br />

Description<br />

Selects Which Function(s) F5 Activates<br />

Values<br />

0 to 255<br />

Initial Value<br />

16 (Blow Down/Increase Chuff Magnitude)<br />

Related CVs<br />

CV33—CV46; CV196—CV205<br />

Bit 7 Bit 0<br />

Volume L1 Water/C- Blow/C+ Air Couple Bell Horn<br />

Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Volume Audio Effects<br />

0 = Not Affected by F4<br />

1 = Volume Increases or Decreases on a Double Press<br />

Volume Mutes on a Single Press<br />

Light One Visual Effects<br />

0 = Not Affected by F4<br />

1 = Visual Light One Activated<br />

Water Fill/Decrease Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Water Fill Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Decreased<br />

Page 27 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 4:<br />

Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

Blow Down/Increase Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Blow Down Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Increased<br />

Air Pump Sound Effects<br />

0 = Not Affected by F0<br />

1 = Air Pump Sound Activated/Deactivated by F0<br />

Coupler Sound Effects<br />

0 = Not Affected by F0<br />

1 = Coupler Sound Activated by F0 if Engine Moving<br />

Uncouple Armed if Engine Stopped<br />

Bell Sound Effects<br />

0 = Not Affected by F4<br />

1 = Bell Activated by F4<br />

Horn Sound Effects (If Model Has This Effect)<br />

0 = Not Affected by F4<br />

1 = Horn Activated by F4<br />

Page 28 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV40<br />

F6 Output Function Definition<br />

FUNCTION CVs<br />

Description<br />

Selects Which Function(s) F6 Activates<br />

Values<br />

0 to 255<br />

Initial Value<br />

32 (Water/Increase Chuff Magnitude)<br />

Related CVs<br />

CV33—CV46; CV196—CV205<br />

Bit 7 Bit 0<br />

Volume L1 Water/C- Blow/C+ Air Couple Bell Horn<br />

Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Volume Audio Effects<br />

0 = Not Affected by F4<br />

1 = Volume Increases or Decreases on a Double Press<br />

Volume Mutes on a Single Press<br />

Light One Visual Effects<br />

0 = Not Affected by F4<br />

1 = Visual Light One Activated<br />

Water Fill/Decrease Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Water Fill Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Decreased<br />

Page 29 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 4:<br />

Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

Blow Down/Increase Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Blow Down Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Increased<br />

Air Pump Sound Effects<br />

0 = Not Affected by F0<br />

1 = Air Pump Sound Activated/Deactivated by F0<br />

Coupler Sound Effects<br />

0 = Not Affected by F0<br />

1 = Coupler Sound Activated by F0 if Engine Moving<br />

Uncouple Armed if Engine Stopped<br />

Bell Sound Effects<br />

0 = Not Affected by F4<br />

1 = Bell Activated by F4<br />

Horn Sound Effects (If Model Has This Effect)<br />

0 = Not Affected by F4<br />

1 = Horn Activated by F4<br />

Page 30 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV41<br />

F7 Output Function Definition<br />

FUNCTION CVs<br />

Description<br />

Selects Which Function(s) F7 Activates<br />

Values<br />

0 to 255<br />

Initial Value<br />

64 (L1 Visual Effects)<br />

Related CVs<br />

CV33—CV46; CV160—CV164<br />

Bit 7 Bit 0<br />

Volume L1 Water/C- Blow/C+ Air Couple Bell Horn<br />

Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Volume Audio Effects<br />

0 = Not Affected by F4<br />

1 = Volume Increases or Decreases on a Double Press<br />

Volume Mutes on a Single Press<br />

Light One Visual Effects<br />

0 = Not Affected by F4<br />

1 = Visual Light One Activated<br />

Water Fill/Decrease Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Water Fill Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Decreased<br />

Page 31 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 4:<br />

Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

Blow Down/Increase Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Blow Down Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Increased<br />

Air Pump Sound Effects<br />

0 = Not Affected by F0<br />

1 = Air Pump Sound Activated/Deactivated by F0<br />

Coupler Sound Effects<br />

0 = Not Affected by F0<br />

1 = Coupler Sound Activated by F0 if Engine Moving<br />

Uncouple Armed if Engine Stopped<br />

Bell Sound Effects<br />

0 = Not Affected by F4<br />

1 = Bell Activated by F4<br />

Horn Sound Effects (If Model Has This Effect)<br />

0 = Not Affected by F4<br />

1 = Horn Activated by F4<br />

Page 32 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV42<br />

F8 Output Function Definition<br />

FUNCTION CVs<br />

Description<br />

Selects Which Function(s) F8 Activates<br />

Values<br />

0 to 255<br />

Initial Value<br />

128 (Volume Audio Effect)<br />

Related CVs<br />

CV33—CV46<br />

Bit 7 Bit 0<br />

Volume L1 Water/C- Blow/C+ Air Couple Bell Horn<br />

Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Volume Audio Effects<br />

0 = Not Affected by F4<br />

1 = Volume Increases or Decreases on a Double Press<br />

Volume Mutes on a Single Press<br />

Light One Visual Effects<br />

0 = Not Affected by F4<br />

1 = Visual Light One Activated<br />

Water Fill/Decrease Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Water Fill Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Decreased<br />

Page 33 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 4:<br />

Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

Blow Down/Increase Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Blow Down Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Increased<br />

Air Pump Sound Effects<br />

0 = Not Affected by F0<br />

1 = Air Pump Sound Activated/Deactivated by F0<br />

Coupler Sound Effects<br />

0 = Not Affected by F0<br />

1 = Coupler Sound Activated by F0 if Engine Moving<br />

Uncouple Armed if Engine Stopped<br />

Bell Sound Effects<br />

0 = Not Affected by F4<br />

1 = Bell Activated by F4<br />

Horn Sound Effects (If Model Has This Effect)<br />

0 = Not Affected by F4<br />

1 = Horn Activated by F4<br />

Page 34 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV43<br />

F9 Output Function Definition<br />

FUNCTION CVs<br />

Description<br />

Selects Which Function(s) F9 Activates<br />

Values<br />

0 to 255<br />

Initial Value<br />

16 (Shutdown and Startup Audio Effect)<br />

Related CVs<br />

CV33—CV46<br />

Bit 7 Bit 0<br />

Brakes Injector Coal Sht/Str L1 Water/C- Blow/C+ Air<br />

Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Brakes Effects<br />

0 = Not Affected by F9<br />

1 = If Engine at Throttle Stop Zero:<br />

Set Air Brake Effect<br />

If Engine not at Throttle Stop Zero:<br />

Release Air Brake Effect Activated<br />

Injector Effect<br />

0 = Not Affected by F9<br />

1 = Water Injector Effect Activated<br />

Shovel Coal<br />

0 = Not Affected by F9<br />

1 = Coal Shovel/Auger Effect Activated<br />

Page 35 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 4:<br />

Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

Shut Down or Start Up <strong>Steam</strong> Engine Sound Effects<br />

0 = Not Affected by F9<br />

1 = If at Idle, Play Shutdown Sound Effect<br />

If not at Idle, ignored.<br />

1= If Silent (Shutdown) than Play Startup Sound Effect<br />

Light One Visual Effects<br />

0 = Not Affected by F9<br />

1 = Visual Light One Activated<br />

Water Fill/Decrease Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Water Fill Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Decreased<br />

Blow Down/Increase Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Blow Down Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Increased<br />

Air Pump Sound Effects<br />

0 = Not Affected by F0<br />

1 = Air Pump Sound Activated/Deactivated by F0<br />

Page 36 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


FUNCTION CVs<br />

CV44<br />

F10 Output Function Definition<br />

Description<br />

Selects Which Function(s) F10 Activates<br />

Values<br />

0 to 255<br />

Initial Value<br />

32 (Shovel/Auger Coal Audio Effect)<br />

Related CVs<br />

CV33—CV46<br />

Bit 7 Bit 0<br />

Brakes Injector Coal Sht/Str L1 Water/C- Blow/C+ Air<br />

Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Brakes Effects<br />

0 = Not Affected by F9<br />

1 = If Engine at Throttle Stop Zero:<br />

Set Air Brake Effect<br />

If Engine not at Throttle Stop Zero:<br />

Release Air Brake Effect Activated<br />

Injector Effect<br />

0 = Not Affected by F9<br />

1 = Water Injector Effect Activated<br />

Shovel Coal<br />

0 = Not Affected by F9<br />

1 = Coal Shovel/Auger Effect Activated<br />

Page 37 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 4:<br />

Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

Shut Down or Start Up <strong>Steam</strong> Engine Sound Effects<br />

0 = Not Affected by F9<br />

1 = If at Idle, Play Shutdown Sound Effect<br />

If not at Idle, ignored.<br />

1= If Silent (Shutdown) than Play Startup Sound Effect<br />

Light One Visual Effects<br />

0 = Not Affected by F9<br />

1 = Visual Light One Activated<br />

Water Fill/Decrease Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Water Fill Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Decreased<br />

Blow Down/Increase Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Blow Down Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Increased<br />

Air Pump Sound Effects<br />

0 = Not Affected by F0<br />

1 = Air Pump Sound Activated/Deactivated by F0<br />

Page 38 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


FUNCTION CVs<br />

CV45<br />

F11 Output Function Definition<br />

Description<br />

Selects Which Function(s) F11 Activates<br />

Values<br />

0 to 255<br />

Initial Value<br />

64 (Water Injector Audio Effect)<br />

Related CVs<br />

CV33—CV46<br />

Bit 7 Bit 0<br />

Brakes Injector Coal Sht/Str L1 Water/C- Blow/C+ Air<br />

Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Brakes Effects<br />

0 = Not Affected by F9<br />

1 = If Engine at Throttle Stop Zero:<br />

Set Air Brake Effect<br />

If Engine not at Throttle Stop Zero:<br />

Release Air Brake Effect Activated<br />

Injector Effect<br />

0 = Not Affected by F9<br />

1 = Water Injector Effect Activated<br />

Shovel Coal<br />

0 = Not Affected by F9<br />

1 = Coal Shovel/Auger Effect Activated<br />

Page 39 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 4:<br />

Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

Shut Down or Start Up <strong>Steam</strong> Engine Sound Effects<br />

0 = Not Affected by F9<br />

1 = If at Idle, Play Shutdown Sound Effect<br />

If not at Idle, ignored.<br />

1= If Silent (Shutdown) than Play Startup Sound Effect<br />

Light One Visual Effects<br />

0 = Not Affected by F9<br />

1 = Visual Light One Activated<br />

Water Fill/Decrease Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Water Fill Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Decreased<br />

Blow Down/Increase Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Blow Down Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Increased<br />

Air Pump Sound Effects<br />

0 = Not Affected by F0<br />

1 = Air Pump Sound Activated/Deactivated by F0<br />

Page 40 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


FUNCTION CVs<br />

CV46<br />

F12 Output Function Definition<br />

Description<br />

Selects Which Function(s) F12 Activates<br />

Values<br />

0 to 255<br />

Initial Value<br />

128 (Brake Audio Effects)<br />

Related CVs<br />

CV33—CV46<br />

Bit 7 Bit 0<br />

Brakes Injector Coal Sht/Str L1 Water/C- Blow/C+ Air<br />

Bit 7:<br />

Bit 6:<br />

Bit 5:<br />

Brakes Effects<br />

0 = Not Affected by F9<br />

1 = If Engine at Throttle Stop Zero:<br />

Set Air Brake Effect<br />

If Engine not at Throttle Stop Zero:<br />

Release Air Brake Effect Activated<br />

Injector Effect<br />

0 = Not Affected by F9<br />

1 = Water Injector Effect Activated<br />

Shovel Coal<br />

0 = Not Affected by F9<br />

1 = Coal Shovel/Auger Effect Activated<br />

Page 41 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Bit 4:<br />

Bit 3:<br />

Bit 2:<br />

Bit 1:<br />

Bit 0:<br />

Shut Down or Start Up <strong>Steam</strong> Engine Sound Effects<br />

0 = Not Affected by F9<br />

1 = If at Idle, Play Shutdown Sound Effect<br />

If not at Idle, ignored.<br />

1= If Silent (Shutdown) than Play Startup Sound Effect<br />

Light One Visual Effects<br />

0 = Not Affected by F9<br />

1 = Visual Light One Activated<br />

Water Fill/Decrease Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Water Fill Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Decreased<br />

Blow Down/Increase Chuff Magnitude Sound Effects<br />

0 = Not Affected by F0<br />

1 = Blow Down Sound Activated by F0 if Engine Stopped<br />

1 = Chuff Magnitude Increased<br />

Air Pump Sound Effects<br />

0 = Not Affected by F0<br />

1 = Air Pump Sound Activated/Deactivated by F0<br />

Page 42 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV130<br />

Master Volume Sound Increment<br />

Description<br />

This Value is the Increment/Decrement Amount for Master Volume<br />

Values<br />

0 to 16<br />

Initial Value<br />

2<br />

Related CVs<br />

CV42, CV133<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 1 0<br />

The decoder’s analog potentiometer (volume control) increases or<br />

decreases the volume of the sound. The change between the 16<br />

available steps may be set from 0 to 16. Every press of the volume<br />

toggle switch will result in a volume change incrementing or<br />

decrementing by this value.<br />

Page 43 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV131<br />

Analog Sound Unit Startup (Turn-On) Voltage<br />

Description<br />

This Value Sets the Decoders Sound Turn-On Voltage<br />

Values<br />

0 to 255<br />

Initial Value<br />

56<br />

Related CVs<br />

CV132, CV133<br />

Bit 7 Bit 0<br />

0 0 1 1 1 0 0 0<br />

The sound unit has a minimum power requirement necessary to play<br />

all sound effects. Many factors contribute to what the necessary<br />

voltage is such as the power source, the startup volume (CV133) and<br />

system loading. Lowering this value will instruct the sound unit to<br />

start the audio effects at a lower voltage. Note: Care should be<br />

taken with this value. Lowering this value too low will result in<br />

the unit not being able to function at all. If this occurs, set this<br />

value to a larger number or the initial value and reprogram the<br />

value in service mode.<br />

Page 44 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV132<br />

Analog Sound Unit Shutdown (Turn-Off) Voltage<br />

Description<br />

This Value Sets the Decoders Sound Turn-Off Voltage<br />

Values<br />

0 to 255<br />

Initial Value<br />

54<br />

Related CVs<br />

CV131, CV133<br />

Bit 7 Bit 0<br />

0 0 1 1 0 1 1 0<br />

The sound unit is instructed to play the shutdown effect and turn off<br />

all effects at this value. The shutdown effect only plays from the idle<br />

condition. Many factors contribute to what this actual voltage is such<br />

as the power source, system volume, individual volumes (CV133,<br />

CV135—CV161) and system loading. Lowering this value will<br />

instruct the sound unit to play the shutdown effect at a lower voltage.<br />

Note: Care should be taken with this value. Lowering this value<br />

too low will result in the unit not being able to play the shutdown<br />

effect and terminate all effects properly. The sound unit could<br />

abruptly shut off. If this occurs, set this value to a larger number or<br />

the initial value.<br />

Page 45 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV133<br />

Sound Unit Master Volume<br />

SOUND CVs<br />

Description<br />

This Value Sets the Power Up Master Sound Effects Volume<br />

Values<br />

0 to 16<br />

Initial Value<br />

15<br />

Related CVs<br />

CV130<br />

Bit 7 Bit 0<br />

0 0 0 0 1 1 1 1<br />

The decoder’s analog potentiometer (volume control) increases or<br />

decreases the volume of the sound. The change between the 16<br />

available steps may be set from 0 to 16. Every press of the volume<br />

toggle switch will result in a volume change incrementing or<br />

decrementing by this value. This value is the decoder’s power up<br />

value. A higher value increases the volume while a lower value<br />

decreases the volume.<br />

Page 46 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV135<br />

Whistle Volume<br />

Description<br />

This Value Controls the Whistle Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV36, CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s whistle sound effect volume is variable from 0 to 255%.<br />

A higher value increases the volume while a lower value decreases<br />

the volume.<br />

Page 47 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV136<br />

Bell Volume<br />

Description<br />

This Value Controls the Bell Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV35, CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s bell sound effect volume is variable from 0 to 255%. A<br />

higher value increases the volume while a lower value decreases the<br />

volume.<br />

Page 48 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV137<br />

<strong>Steam</strong> Volume<br />

Description<br />

This Value Controls the Startup, Three Backgrounds and Shutdown<br />

Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s steam engine sound effects volume is variable from 0<br />

to 255%. A higher value increases the volume while a lower value<br />

decreases the volume. This value controls a group of sounds: steam<br />

startup, three unique steam backgrounds and steam shutdown sound<br />

effects.<br />

Page 49 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV138<br />

Horn Volume<br />

Description<br />

This Value Controls the Horn Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s horn sound effect volume is variable from 0 to 255%.<br />

A higher value increases the volume while a lower value decreases<br />

the volume. Note: This sound effect is not used in most engines.<br />

Page 50 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV140<br />

Couple Volume<br />

Description<br />

This Value Controls the Couple Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV37, CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s couple sound effect volume is variable from 0 to 255%.<br />

The couple sound effect only plays if the engine is moving and the<br />

function is pressed. This sound effect may be activated with a DCC<br />

Function or AUX with a DCMaster. A higher value increases the<br />

volume while a lower value decreases the volume.<br />

Page 51 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV141<br />

Uncouple Volume<br />

Description<br />

This Value Controls the Uncouple Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV37, CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s uncouple sound effect volume is variable from 0 to<br />

255%. The uncouple sound effect plays once after it is armed. The<br />

process of arming is: press the function with engine stopped, upon<br />

engine moving the uncouple sound effect plays. This sound effect<br />

may be activated with a DCC Function or AUX with a DCMaster. A<br />

higher value increases the volume while a lower value decreases the<br />

volume.<br />

Page 52 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV143<br />

Air Pump Volume<br />

Description<br />

This Value Controls the Air Pump Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV38, CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s air pump sound effect volume is variable from 0 to<br />

255%. The air pump sound effect plays if the engine is stopped or<br />

moving. This sound effect may be activated with a DCC Function or<br />

AUX with a DCMaster and is also a random sound effect when<br />

stopped. A higher value increases the volume while a lower value<br />

decreases the volume.<br />

Page 53 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV144<br />

Blow Down Volume<br />

SOUND CVs<br />

Description<br />

This Value Controls the Blow Down Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV45, CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s blow down sound effect volume is variable from 0 to<br />

255%. This sound effect may be activated with a DCC Function only<br />

if the engine is stopped and is also a random sound effect when<br />

stopped. A higher value increases the volume while a lower value<br />

decreases the volume.<br />

Page 54 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV145<br />

<strong>Steam</strong> Cock Volume<br />

SOUND CVs<br />

Description<br />

This Value Controls the <strong>Steam</strong> Cock Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV45, CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s steam cock sound effects volume is variable from 0 to<br />

255%. This sound effect is a random sound effect that only plays<br />

when stopped. A higher value increases the volume while a lower<br />

value decreases the volume.<br />

Page 55 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV146<br />

Brake Set Volume<br />

Description<br />

This Value Controls the Brake Set Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV46, CV133, CV191, CV209, CV227<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s brake set sound effect volume is variable from 0 to<br />

255%. The brake set sound effect only plays if the track voltage falls<br />

below the analog brake set voltage (CV191) for analog mode or<br />

pressing the Function for DCC. In DCC mode the brake set effect<br />

plays when the current speed step matches or is lower than the DCC<br />

Brake Set Throttle Stop (CV209). A higher value increases the<br />

volume while a lower value decreases the volume.<br />

Page 56 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV147<br />

Brake Release Volume<br />

SOUND CVs<br />

Description<br />

This Value Controls the Brake Release Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV46, CV133, CV192, CV210, CV227<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s brake release sound effect volume is variable from 0 to<br />

255%. The brake release sound effect only plays if the track voltage is<br />

increased above the analog brake set voltage (CV192) for analog<br />

mode or pressing the Function for DCC. In DCC mode the brake<br />

release effect plays when the current speed step matches or is higher<br />

than the DCC Brake Release Throttle Stop (CV210). A higher value<br />

increases the volume while a lower value decreases the volume.<br />

Page 57 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV148<br />

Pop Off Valve Volume<br />

SOUND CVs<br />

Description<br />

This Value Controls the Pop Off Valve Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s pop off valve sound effect volume is variable from 0 to<br />

255%. The pop off valve sound effect is a random sound that only<br />

plays when the engine is stopped. A higher value increases the<br />

volume while a lower value decreases the volume.<br />

Page 58 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV149<br />

Blower Volume<br />

Description<br />

This Value Controls the Blower Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV44, CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s blower sound effect volume is variable from 0 to 255%.<br />

This sound effect is a random sound effect when the engine is<br />

stopped. A higher value increases the volume while a lower value<br />

decreases the volume.<br />

Page 59 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV150<br />

Dynamo Volume<br />

Description<br />

This Value Controls the Dynamo Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV38, CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s dynamo sound effect volume is variable from 0 to<br />

255%. The dynamo on sound effect plays for a short period before<br />

the headlights are turned on. The sound effect then fades into the<br />

background. The dynamo off sound effect plays for a short period<br />

after the lights are turned off. The sound effect then fades into the<br />

background. A higher value increases the volume while a lower<br />

value decreases the volume.<br />

Page 60 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV151<br />

Brakes Squeal Volume<br />

SOUND CVs<br />

Description<br />

This Value Controls the Brakes Squeal Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV46, CV133, CV227<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s brake squeal sound effect volume is variable from 0 to<br />

255%. In analog and DCC mode, the brakes squeal sound effect plays<br />

if the change in track voltage (analog mode [CV184]) or the speed<br />

steps (DCC Mode [CV185]) exceeds the preset threshold. The brakes<br />

squeal sound effect plays if the DCC Function is enabled (CV227). A<br />

higher value increases the volume while a lower value decreases the<br />

volume.<br />

Page 61 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV152<br />

Shovel/Auger Coal Volume<br />

SOUND CVs<br />

Description<br />

This Value Controls the Shovel Coal Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s shovel/auger coal sound effect volume is variable from<br />

0 to 255%. The shovel/auger coal sound effect plays by pressing the<br />

Function for DCC. The shovel/auger coal sound effect is a random<br />

sound that only plays when the engine is stopped. This sound effect<br />

is also a random sound that plays when the engine is stopped. A<br />

higher value increases the volume while a lower value decreases the<br />

volume.<br />

Page 62 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV153<br />

Water Fill Volume<br />

Description<br />

This Value Controls the Water Fill Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s water fill sound effect volume is variable from 0 to<br />

255%. The water fill sound effect plays by pressing the Function for<br />

DCC. The water fill sound effect only plays when the engine is<br />

stopped. A higher value increases the volume while a lower value<br />

decreases the volume.<br />

Page 63 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV154<br />

Injector Volume<br />

Description<br />

This Value Controls the Water Injector Sound Effects Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV133<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s water injector sound effect volume is variable from 0<br />

to 255%. The water injector sound effect plays by pressing the<br />

Function for DCC. This sound effect is also a random sound that<br />

plays when the engine is stopped. A higher value increases the<br />

volume while a lower value decreases the volume.<br />

Page 64 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SOUND CVs<br />

CV155<br />

Chuff/<strong>Steam</strong> Cock Chuffs Volume<br />

Description<br />

This Value Controls the Chuff and <strong>Steam</strong> Cock Chuffs Sound Effects<br />

Volume<br />

Values<br />

0 to 255<br />

Initial Value<br />

100<br />

Related CVs<br />

CV133, CV196<br />

Bit 7 Bit 0<br />

0 1 1 0 0 1 0 0<br />

The decoder’s chuff and steam cock chuffs sound effect volume is<br />

variable from 0 to 255%. A higher value increases the volume while a<br />

lower value decreases the volume.<br />

Page 65 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Lighting CVs<br />

CV159<br />

System Lighting<br />

Description<br />

This Value Controls System Lighting Functions<br />

Values<br />

0-255<br />

Initial Value<br />

0<br />

Related CVs<br />

CV209, CV210, CV227; CV191, CV192<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 0<br />

The decoder’s visual lighting effects for the front and rear light are<br />

configured here. Rule 17 lighting may be enabled or disabled by<br />

writing a “0” or a “1” to Value. In addition, separate bits allow for<br />

independent control of Rule 17 for DCC or DC.<br />

Rule 17 Lighting<br />

Rule 17 Lighting says “Headlights shall be dimmed when standing<br />

at stations or waiting on side tracks for an oncoming train”. When<br />

rule 17 lighting is enabled, the headlight will be noticeable dimmed<br />

at appropriately times.<br />

Page 66 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


DCC Rule 17 Lighting<br />

For DC operators, the lights will dim per rule 17 when the brake set<br />

sound effect plays (CV209). The lights will return to normal<br />

brightness when the brake release sound plays (CV210). In addition,<br />

CV227 allows for disabling the brake set and brake release. Disabling<br />

these automatic effects does disable rule 17 lighting. Only CV159 can<br />

disable rule 17 lighting.<br />

DC Rule 17 Lighting<br />

For DC operators, the lights will dim per rule 17 when the brake set<br />

sound effect plays (CV191). The lights will return to normal<br />

brightness when the brake release sound plays (CV192).<br />

Bit7:<br />

Bit6:<br />

Bit5:<br />

Bit4:<br />

Bit3:<br />

Bit2:<br />

Bit1:<br />

Bit0:<br />

Not used<br />

Not used<br />

Not used<br />

0=DC Rule 17 Lighting Enabled<br />

1=DC Rule 17 Lighting Disabled<br />

Not used<br />

Not used<br />

Not used<br />

0=DCC Rule 17 Lighting Enabled<br />

1= DCC Rule 17 Lighting Disabled<br />

Page 67 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV160<br />

L1 Light Definition<br />

Lighting CVs<br />

Description<br />

This Value Sets the Function Type and Definition for Output L1<br />

Values<br />

0 to 3<br />

Initial Value<br />

1<br />

Related CVs<br />

CV161, CV162, CV163, CV164, CV210, CV215<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 1<br />

The decoder’s visual lighting effects for L1 output may be one of<br />

three types. Each defined type then uses 2 to 4 of the next 4 CV’s<br />

allowing uses definition of all the parameters. CV210 must be<br />

configured to enable L1 for analog modes. CV215 must be configured<br />

to enable L1 for DCC modes. CV210 allows for L1 activating by the<br />

Whistle for ditch lights. The ditch lights may be type 1, 2 or 3.<br />

Type 0:<br />

Output is disabled.<br />

Page 68 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Type 1:<br />

Duty Cycle Strobe. CV161 defines the on time and CV162<br />

defines the off time. Time is measured in 1/32 seconds<br />

per count.<br />

CV161<br />

Example:<br />

CV162<br />

CV160=1<br />

CV161=32 for 1 second on<br />

CV162=64 for 2 seconds off<br />

Type 2:<br />

Double Pulsed Duty Cycle Strobe. CV161 defines the on<br />

time one; CV162 defines off time one; CV163 defines on<br />

time two; CV164 defines off time two. Time is measured<br />

in 1/32 seconds per count.<br />

CV161 CV162 CV163 CV164<br />

Example:<br />

CV160=2<br />

CV161=8 for .25 seconds for on time one<br />

CV162=16 for .5 seconds for off time one<br />

CV163=16 for .5 seconds for on time two<br />

CV164=64 for 2 seconds for off time two<br />

Page 69 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Type 3:<br />

Ramped Duty Cycle. CV161 defines the start of the on<br />

time within the period; CV162 defines the ramp up time;<br />

CV163 defines the end of the on time within the period;<br />

CV164 defines the ramp down time. The period is 127<br />

counts. CV161 < CV163 and both should be less than 128.<br />

CV162 and CV164 can be any range from 0 to 255.<br />

0 127<br />

On Time<br />

Ramp Up<br />

Light On<br />

CV161<br />

Ramp Down<br />

CV163<br />

The time between 0 and CV161 represents the total time<br />

the light is turned on over one period. The actual period<br />

time (0 to 127) is 11.6ms. CV162 is a ramp up timer<br />

determining how many periods elapse before the On<br />

Time is increased by one. Once CV161 increases to CV163<br />

value, the ramp down begins. CV164 is a ramp down<br />

timer determining how many periods elapse before the<br />

On Time is decreases by one. Once CV163 decreases to<br />

CV161, the ramp up cycle repeats, etc.<br />

Soft Strobe Example:<br />

CV160=3<br />

CV161=10<br />

CV162=100<br />

CV163=127<br />

CV164=100<br />

Ditch Light Example: CV160=3<br />

CV161=0<br />

CV162=10<br />

CV163=180<br />

CV164=10<br />

Page 70 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Lighting CVs<br />

CV161<br />

L1 Parameter One<br />

Description<br />

This Value is a Light Parameter, Dependant on CV160<br />

Values<br />

Dependant on Type<br />

Initial Value<br />

10<br />

Related CVs<br />

CV160, CV162, CV163, CV164<br />

Bit 7 Bit 0<br />

0 0 0 0 1 0 1 0<br />

Type 0: Not Used<br />

Type1: Sets the On Time; Valid Values 0-255<br />

Type2: Sets On Time One; Valid Values 0-255<br />

Type3: Sets the Start Point for Power On; Valid Values 0-255<br />

CV161


Lighting CVs<br />

CV162<br />

L1 Parameter Two<br />

Description<br />

This Value is a Light Parameter, Dependant on CV160<br />

Values<br />

Dependant on Type<br />

Initial Value<br />

10<br />

Related CVs<br />

CV160, CV161, CV163, CV164<br />

Bit 7 Bit 0<br />

0 0 0 0 1 0 1 0<br />

Type 0: Not Used<br />

Type1: Sets the Off Time; Valid Values 0-255<br />

Type2: Sets Off Time One; Valid Values 0-255<br />

Type3: Sets the Ramp Up Time; Valid Values 0-255<br />

Time measured in 11.6ms per count<br />

Page 72 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV163<br />

L1 Parameter Three<br />

Lighting CVs<br />

Description<br />

This Value is a Light Parameter, Dependant on CV160<br />

Values<br />

Dependant on Type<br />

Initial Value<br />

180<br />

Related CVs<br />

CV160, CV161, CV162, CV164<br />

Bit 7 Bit 0<br />

1 0 1 1 0 1 0 0<br />

Type 0: Not Used<br />

Type1: Not Used<br />

Type2: Sets On Time Two; Valid Values 0-255<br />

Type3: Sets the End Point for Power On; Valid Values 0-255<br />

CV163>CV161<br />

Page 73 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Lighting CVs<br />

CV164<br />

L1 Parameter Four<br />

Description<br />

This Value is a Light Parameter, Dependant on CV160<br />

Values<br />

Dependant on Type<br />

Initial Value<br />

20<br />

Related CVs<br />

CV160, CV161, CV162, CV163<br />

Bit 7 Bit 0<br />

0 0 0 1 0 1 0 0<br />

Type 0: Not Used<br />

Type1: Not Used<br />

Type2: Sets Off Time Two; Valid Values 0-255<br />

Type3: Sets the Ramp Down Time; Valid Values 0-255<br />

Time measured in 11.6ms per count<br />

Page 74 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV180<br />

Bell Ring Interval<br />

Description<br />

This Value Controls the Time Interval Between Bell Strikes<br />

Values<br />

0-120<br />

Initial Value<br />

Varies With Each Bell Sound Effect<br />

Related CVs<br />

CV35<br />

Bit 7 Bit 0<br />

D7 D6 D5 D4 D3 D2 D1 D0<br />

The decoder’s bell ring interval allows the user to customize the time<br />

duration between bell strikes. Increasing this value will increase the<br />

time between bell strikes. This value is updated in operations mode.<br />

Turn on the bell and change this value and hear the bell ring interval<br />

change.<br />

Page 75 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV181<br />

Whistle Fade In Control<br />

SETUP CVs<br />

Description<br />

This Value Controls the Fade-In of the Whistle<br />

Values<br />

0-255<br />

Initial Value<br />

Varies<br />

Related CVs<br />

CV182, CV183<br />

Bit 7 Bit 0<br />

D7 D6 D5 D4 D3 D2 D1 D0<br />

The decoder’s background effects volumes are decreased when a<br />

whistle effect starts to play. This value controls the rate of which the<br />

background fades out while the whistle fades in.<br />

Page 76 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV182<br />

Whistle Fade Out Control<br />

SETUP CVs<br />

Description<br />

This Value Controls the Fade-Out of the Whistle<br />

Values<br />

0-255<br />

Initial Value<br />

Varies<br />

Related CVs<br />

CV181, CV183<br />

Bit 7 Bit 0<br />

D7 D6 D5 D4 D3 D2 D1 D0<br />

The decoder’s background effects volumes are increased while a<br />

whistle effect begins termination. This value controls the rate of<br />

which the background fades in while the whistle fades out.<br />

Page 77 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV183<br />

Whistle Fade In Level<br />

SETUP CVs<br />

Description<br />

This Value Controls the Fade-In of the Whistle<br />

Values<br />

0-255<br />

Initial Value<br />

Varies<br />

Related CVs<br />

CV181, CV182<br />

Bit 7 Bit 0<br />

D7 D6 D5 D4 D3 D2 D1 D0<br />

The decoder’s background effects volumes decrease when a whistle<br />

effect starts fading in. This value controls the background fade level<br />

for the whistle fade in.<br />

Page 78 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV184<br />

Analog Brake Control<br />

SETUP CVs<br />

Description<br />

This Value Controls Analog Brake Effect Activation<br />

Values<br />

0-255<br />

Initial Value<br />

64<br />

Related CVs<br />

Bit 7 Bit 0<br />

0 1 0 0 0 0 0 0<br />

The decoder’s brake squeal effect plays when a track voltage<br />

threshold is met. The threshold is met when the track voltage<br />

decreases fast enough to meet this threshold (CV184). Increasing this<br />

value decreases the brake sensitivity.<br />

Page 79 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV185<br />

DCC Brake Control<br />

SETUP CVs<br />

Description<br />

This Value Controls DCC Brake Effect Activation<br />

Values<br />

0-255<br />

Initial Value<br />

20<br />

Related CVs<br />

CV46, CV186, CV227<br />

Bit 7 Bit 0<br />

0 0 0 1 0 1 0 0<br />

The decoder’s brake squeal effect plays when a speed step threshold<br />

is met. The threshold is met when the speed step decreases fast<br />

enough to meet this threshold (CV185). Increasing this value<br />

decreases the brake sensitivity. Clearing bit1 of CV227 disables the<br />

brake squeal sound effect.<br />

Page 80 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV186<br />

DCC Brake/Magnitude Timer<br />

Description<br />

This Value Controls DCC Brake Effect and Chuff Magnitude<br />

Activation<br />

Values<br />

0-255<br />

Initial Value<br />

1<br />

Related CVs<br />

CV46, CV185, CV200, CV201<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 1<br />

The decoder’s brake squeal effect plays when a speed step threshold<br />

is met (CV185). The threshold is met when the speed step decreases<br />

fast enough to meet this threshold (CV185). This value determines<br />

when the current speed step is sampled. Increasing this value<br />

decreases brake sensitivity.<br />

The decoders chuff magnitude increase and chuff magnitude<br />

decrease also uses the current speed step sampled at this time<br />

interval. See CV200 and CV201.<br />

Page 81 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV187<br />

DCC Uncouple Throttle Stop<br />

Description<br />

This Value Controls When the Uncouple Effect Plays<br />

Values<br />

0-255<br />

Initial Value<br />

3<br />

Related CVs<br />

CV37<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 1 1<br />

The decode plays the uncouple sound effects at this value of throttle<br />

stop if the uncouple sound is armed. Arm the uncouple effects by<br />

activating the uncouple Function when the engine is stopped.<br />

Page 82 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV188<br />

Pitch Shift<br />

Description<br />

This Value Controls the Total Pitch of all Sound Effects<br />

Values<br />

0-255<br />

Initial Value<br />

128<br />

Related CVs<br />

Bit 7 Bit 0<br />

1 0 0 0 0 0 0 0<br />

The decoder’s sound effects pitch is controlled by this value.<br />

Increasing this value increases all sound effect pitches. This value is<br />

updated in operations mode. Turn on the bell or set the whistle to<br />

the bell (CV35 = 4). With the whistle or bell on constantly, change<br />

this value and hear the pitch shift.<br />

Page 83 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV190<br />

Analog Sound Setup<br />

SETUP CVs<br />

Description<br />

This Value Contains Various Analog Sound Setup Features<br />

Values<br />

0-255<br />

Initial Value<br />

1-4<br />

Related CVs<br />

CV131, CV132, CV191, CV192<br />

Bit 7 Bit 0<br />

D7 D6 D5 D4 D3 D2 D1 D0<br />

This value is write Only. Prior to writing this value, use the<br />

DCMaster and save the desired track voltage. The voltage is saved<br />

by Muting the sounds, than Pressing AUX. The current track voltage<br />

is saved for later storage. Writing the following value to CV190<br />

indicates where the saved voltage is applied.<br />

Value What is saved Destination of Saved Track Voltage<br />

4 Analog Brake Release Voltage CV192<br />

3 Analog Brake Set Voltage CV191<br />

2 Shut Down Voltage CV132<br />

1 Sound Start Up Voltage CV131<br />

Page 84 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV191<br />

Analog Brake Set Voltage<br />

SETUP CVs<br />

Description<br />

This Value Sets the Track Voltage for Brake Set Sound Effect<br />

Values<br />

0-255<br />

Initial Value<br />

70<br />

Related CVs<br />

CV146, CV192<br />

Bit 7 Bit 0<br />

0 1 0 0 0 1 1 0<br />

The decoder’s analog brake set sound effect is activated when the<br />

track voltage reaches this value. Increasing this value increases the<br />

track voltage threshold needed before the brake set sound effect<br />

plays. Note: This value must be lower than the analog brake<br />

release voltage CV192.<br />

Page 85 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV192<br />

Analog Brake Release Voltage<br />

Description<br />

This Value Sets the Track Voltage for Brake Release Sound Effect<br />

Values<br />

0-255<br />

Initial Value<br />

77<br />

Related CVs<br />

CV147, CV191<br />

Bit 7 Bit 0<br />

0 1 0 0 1 1 0 1<br />

The decoder’s analog brake release sound effect is activated when the<br />

track voltage reaches this value. Increasing this value increases the<br />

track voltage threshold needed before the brake release sound effect<br />

plays. Note: This value must be higher than the analog brake set<br />

voltage CV191.<br />

Page 86 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV196<br />

<strong>Steam</strong> Cock Chuffs Event Count<br />

Description<br />

This Value Sets the <strong>Steam</strong> Cock Chuff Event Counter<br />

Values<br />

0-255<br />

Initial Value<br />

1<br />

Related CVs<br />

CV155<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 1<br />

The decoder’s steam cock chuffs sound effect is activated at the initial<br />

power up and after the engine is stopped from moving for 30<br />

seconds. This value determines how many sets of four chuffs or<br />

drive wheel revolutions this sound effect plays at initial motion<br />

before the normal chuffs start playing. Increasing this value increases<br />

the amount of steam cock chuffs at first motion while decreasing this<br />

values decrease the amount of steam cock chuffs. Setting this value<br />

to zero turns off this sound effect. CV155 controls the volume of this<br />

sound effect.<br />

Page 87 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV197<br />

Rod Knock Chuffs Event Count<br />

Description<br />

This Value Sets the Rod Knock Event Counter<br />

Values<br />

0-255<br />

Initial Value<br />

2<br />

Related CVs<br />

CV198, CV201, CV203<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 1 0<br />

The decoder’s rod knock sound effects play during a de-acceleration.<br />

This de-acceleration change is determined by CV203 for DC and<br />

CV201 for DCC. The automatic volume change is determined by<br />

CV198. The value for CV197, determines how many wheel<br />

revelations the rod knock chuff plays.<br />

Page 88 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV198<br />

Rod Knock Volume<br />

SETUP CVs<br />

Description<br />

This Value Sets the Rod Knock Volume Sound Effect<br />

Values<br />

0-255<br />

Initial Value<br />

80<br />

Related CVs<br />

CV197, CV201, CV203<br />

Bit 7 Bit 0<br />

0 1 0 1 0 0 0 0<br />

The decoder’s rod knock sound effects play during a de-acceleration.<br />

This de-acceleration change is determined by CV203 for DC and<br />

CV201 for DCC. The automatic volume change is determined by<br />

CV198. The value for CV197, determines how many wheel<br />

revelations the rod knock chuff plays. The rod knock volume is<br />

applied when the de-acceleration parameter is met. This volume is<br />

slowly returned back to its initial volume as the normal chuffs play.<br />

Page 89 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV199<br />

Chuff Magnitude Increase Volume<br />

Description<br />

This Value Sets Chuff Magnitude Increased Volume Sound Effect<br />

Values<br />

0-255<br />

Initial Value<br />

255<br />

Related CVs<br />

CV155, CV200, CV202<br />

Bit 7 Bit 0<br />

1 1 1 1 1 1 1 1<br />

The decoder’s chuff sound effects magnitude changes during<br />

acceleration. This acceleration is determined by CV202 for DC and<br />

CV200 for DCC. This value for CV199 determines the magnitude<br />

change from the normal chuff. Assume that CV155 is 100. If CV199<br />

is 200, than the magnitude difference is 100%. Note: If CV155 is set<br />

higher than CV199, than a magnitude difference will be difficult to<br />

hear.<br />

Page 90 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV200<br />

DCC Throttle Magnitude Increase<br />

Description<br />

This Value Sets the DCC Throttle Magnitude Increase Sound<br />

Values<br />

0-255<br />

Initial Value<br />

1<br />

Related CVs<br />

CV186, CV199, CV201<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 1<br />

An increasing change in throttle causes the chuff sound effects<br />

magnitude to increase. This value determines the throttle change<br />

over time that triggers this magnitude change in the chuff sound<br />

effect. CV186 determines the throttle sample time period. Increasing<br />

this value increases the throttle stops necessary over the timed period<br />

CV186 to trigger this event. Decreasing this value decreases the<br />

throttle stops necessary over the timed period CV186 to trigger this<br />

event.<br />

Page 91 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV201<br />

DCC Throttle Magnitude Decrease<br />

Description<br />

This Value Sets the DCC Throttle Magnitude Decrease Sound<br />

Values<br />

0-255<br />

Initial Value<br />

1<br />

Related CVs<br />

CV186, CV197, CV198, CV199, CV200<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 1<br />

A decreasing change in throttle causes the chuff sound effects<br />

magnitude to decrease. Also, the chuff sounds changes to a rod<br />

knock sound. See CV197 and CV198. This value, CV201, determines<br />

the throttle change over time that triggers this magnitude change in<br />

the chuff sound effect. CV186 determines the throttle sample time<br />

period. Increasing this value increases the throttle stops necessary<br />

over the timed period CV186 to trigger this event. Decreasing this<br />

value decreases the throttle stops necessary over the timed period<br />

CV186 to trigger this event.<br />

Page 92 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV202<br />

DC Track Change Magnitude Increase<br />

Description<br />

This Value Sets the DC Track Voltage Necessary for a Chuff<br />

Magnitude Increase<br />

Values<br />

0-255<br />

Initial Value<br />

160<br />

Related CVs<br />

CV199, CV203<br />

Bit 7 Bit 0<br />

1 0 1 0 0 0 0 0<br />

An increasing change in track voltage causes the chuff sound effects<br />

magnitude to increase. This value determines the track voltage<br />

increase necessary to trigger this event. Increasing this value<br />

increases the track voltage change necessary to trigger this event.<br />

Decreasing this value decreases the track voltage change necessary to<br />

trigger this event.<br />

Page 93 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV203<br />

DC Track Change Magnitude Decrease<br />

Description<br />

This Value Sets the DC Track Voltage Necessary for a Chuff<br />

Magnitude Decrease<br />

Values<br />

0-255<br />

Initial Value<br />

160<br />

Related CVs<br />

CV197, CV198, CV199, CV202<br />

Bit 7 Bit 0<br />

1 0 1 0 0 0 0 0<br />

A decreasing change in track voltage causes the chuff sound effects<br />

magnitude to decrease. Also, the chuff sounds changes to a rod<br />

knock sound. See CV197 and CV198. This value determines the track<br />

voltage decrease necessary to trigger this event. Increasing this value<br />

increases the track voltage change necessary to trigger this event.<br />

Decreasing this value decreases the track voltage change necessary to<br />

trigger this event.<br />

Page 94 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV204<br />

F5 Chuff Magnitude Change Increment<br />

Description<br />

This Value Sets the Change Increment for F5<br />

Values<br />

0-255<br />

Initial Value<br />

32<br />

Related CVs<br />

CV199, CV205<br />

Bit 7 Bit 0<br />

0 0 1 0 0 0 0 0<br />

Pressing the F5 or its assigned function key increases the chuff<br />

magnitude. Each successive press increases the chuff magnitude<br />

until the magnitude reaches 255%. This value determines the<br />

increase per press. The chuff magnitude automatically returns to its<br />

previous value over a time period.<br />

Page 95 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV205<br />

F6 Chuff Magnitude Change Decrement<br />

Description<br />

This Value Sets the Change Decrement for F6<br />

Values<br />

0-255<br />

Initial Value<br />

32<br />

Related CVs<br />

CV199, CV204<br />

Bit 7 Bit 0<br />

0 0 1 0 0 0 0 0<br />

Pressing the F6 or its assigned function key decreases the chuff<br />

magnitude. Each successive press decreases the chuff magnitude<br />

until the magnitude reaches 0%. This value determines the decrease<br />

per press. The chuff magnitude automatically returns to its previous<br />

value over a time period.<br />

Page 96 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV208<br />

DCC Cab Light Throttle Stop<br />

Description<br />

This Value Sets the Throttle Stop for Turning off the Cab Light<br />

Values<br />

0-255<br />

Initial Value<br />

3<br />

Related CVs<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 1 1<br />

The decoder’s Cab light is turned off at this value. A throttle stop<br />

below this value will turn on the Cab light.<br />

Page 97 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV209<br />

DCC Brake Set Throttle Stop<br />

Description<br />

This Value Sets the Throttle Stop for the Brake Set Sound Effect<br />

Values<br />

0-128<br />

Initial Value<br />

0<br />

Related CVs<br />

CV227<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 0<br />

`The decoder’s sound effect for brake set plays at this throttle stop<br />

if this effect is enabled.<br />

Page 98 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SETUP CVs<br />

CV210<br />

DCC Brake Release Throttle Stop<br />

Description<br />

This Value Sets the Throttle Stop for the Brake Release Sound Effect<br />

Values<br />

0-128<br />

Initial Value<br />

2<br />

Related CVs<br />

CV227<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 1 0<br />

The decoder’s sound effect for brake release plays at this throttle<br />

stop if this effect is enabled.<br />

Page 99 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV220<br />

Analog Control One<br />

CONTROL CVs<br />

Description<br />

This Value Contains Various Analog Control Bits<br />

Values<br />

0-255<br />

Initial Value<br />

3<br />

Related CVs<br />

CV160, CV221<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 1 1<br />

Bit7:<br />

Bit6:<br />

Bit5:<br />

Bit4:<br />

Bit3:<br />

Bit2:<br />

Bit1:<br />

Bit0:<br />

Not used<br />

Not used<br />

Not used<br />

0=L1 Does not Activate on Bell or Whistle<br />

1=L1 Activates on Bell or Whistle (See CV221)<br />

Not used<br />

Not used<br />

0=L1 Disabled<br />

1=L1 Enabled<br />

0=Front and Rear Lights Disabled<br />

1=Front and Rear Lights Enabled<br />

Page 100 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV221<br />

Analog Control Two<br />

CONTROL CVs<br />

Description<br />

This Value Contains Various Analog Control Bits<br />

Values<br />

0-255<br />

Initial Value<br />

0<br />

Related CVs<br />

CV220<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 0<br />

Bit7:<br />

Bit6:<br />

Bit5:<br />

Bit4:<br />

Bit3:<br />

Bit2:<br />

Bit1:<br />

Bit0:<br />

Not used<br />

Not used<br />

Not used<br />

Not used<br />

Not used<br />

Not used<br />

Not used<br />

0=Whistle Activates L1 (See Bit 4 CV220)<br />

1=Bell Activates L1 (See Bit 4 CV220)<br />

Page 101 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CONTROL CVs<br />

CV222<br />

Analog AUX Select for DCMaster<br />

Description<br />

This Value Sets the Function for AUX on the DCMaster<br />

Values<br />

0-255<br />

Initial Value<br />

0<br />

Related CVs<br />

CV220<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 0<br />

AUX Control<br />

Value<br />

Air Pump 0<br />

Coupler Sound Effects 1<br />

Front/Rear Light Control 2<br />

L1 Light Control 3<br />

Writing 0 allows the AUX key to play the air pump<br />

Writing 1 allows the AUX key to play the coupler sound effect<br />

Writing 2 allows the AUX to control the front and rear lights if<br />

CV220 bit 0 is set.<br />

Writing 3 allows the AUX to control L1 if CV220 bit 1 is set and<br />

CV220 bit 4 is cleared.<br />

Page 102 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV223<br />

DC Extended Consist Control<br />

CONTROL CVs<br />

Description<br />

This Value Controls Extended DC Consist Lighting<br />

Values<br />

0-255<br />

Initial Value<br />

135<br />

Related CVs<br />

CV19, CV21, CV22, CV221, CV222, CV224<br />

Bit 7 Bit 0<br />

1 0 0 0 0 1 1 1<br />

Bit7:<br />

Bit6:<br />

Bit5:<br />

Bit4:<br />

Bit3:<br />

Bit2:<br />

Bit1:<br />

Bit0:<br />

AUX Disabled=0; AUX Enabled=1<br />

Whistle Disabled=0; Whistle Enabled=1<br />

Bell Disabled=0; Bell Enabled=1<br />

Not used<br />

Not used<br />

L1 Disabled=0; L1 Enabled=1<br />

Front Light Disabled=0; Front Light Enabled=1<br />

Rear Light Disabled=0; Rear Light Enabled=1<br />

See Consist, a technical discussion<br />

Page 103 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CONTROL CVs<br />

CV224<br />

DC Easy Consist<br />

Description<br />

This Value Allows Convenient DC Consist Configuration<br />

Values<br />

1,2,3<br />

Initial Value<br />

0<br />

Related CVs<br />

CV19, V21, CV22, CV221, CV222, CV223<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 0<br />

The easy consist feature sets the decoder CV19 for consist 60 forward<br />

facing engine. Select 1, 2 or 3 for value to set the consist position.<br />

Values:<br />

0 = Consist Disabled<br />

1 = Front Engine<br />

Front light, L1 and AUX enabled (CV223)<br />

Whistle and Bell enabled<br />

2 = Middle Engine<br />

All lights and AUX disabled (CV223)<br />

Whistle and Bell disabled<br />

3 = Rear Engine<br />

Rear light enabled (CV223)<br />

Whistle and Bell disabled<br />

Page 104 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


The consist may be disabled by setting CV19 to zero or CV224 to<br />

zero. The AUX function setup (CV222) for DCMaster is honored in<br />

the consist. Using the Easy Consist feature allows a quick<br />

programming of a basic consist.<br />

Front Engine<br />

All lights are active accept the reverse light. The AUX function is<br />

enabled when the consist is addressed. The Whistle and Bell are<br />

enabled. If a change in the AUX function key is required, modify<br />

CV222. If a change in the lighting or Whistle or Bell is required<br />

modify CV223.<br />

Middle Engine<br />

All lights are inactive. The AUX function is disabled. The Whistle and<br />

Bell are disabled. If a change in the AUX function key is required,<br />

modify CV222. If a change in the lighting or Whisitle or Bell is<br />

required modify CV223.<br />

Rear Engine<br />

Only the reverse light is active. The Whistle, Bell and AUX are<br />

disabled. If a change in the AUX function key is required, modify<br />

CV222. If a change in the lighting or Whistle or Bell is required<br />

modify CV223.<br />

See Consist, a technical discussion<br />

Page 105 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CONTROL CVs<br />

CV225<br />

DCC Control One<br />

Description<br />

This Value Contains Various DCC Control Bits<br />

Values<br />

0-255<br />

Initial Value<br />

3<br />

Related CVs<br />

CV160, CV226<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 1 1<br />

Bit7:<br />

Bit6:<br />

Bit5:<br />

Bit4:<br />

Bit3:<br />

Bit2:<br />

Bit1:<br />

Bit0:<br />

Not used<br />

Not used<br />

Not used<br />

0=L1 Does not Activate on Bell or Whistle<br />

1=L1 Activates on Bell or Whistle (See CV226)<br />

Not used<br />

Not used<br />

0=L1 Disabled<br />

1=L1 Enabled<br />

0=Front and Rear Lights Disabled<br />

1=Front and Rear Lights Enabled<br />

Page 106 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CONTROL CVs<br />

CV226<br />

DCC Control Two<br />

Description<br />

This Value Contains Various DCC Control Bits<br />

Values<br />

0-255<br />

Initial Value<br />

0<br />

Related CVs<br />

CV225<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 0<br />

Bit7:<br />

Bit6:<br />

Bit5:<br />

Bit4:<br />

Bit3:<br />

Bit2:<br />

Bit1:<br />

Bit0:<br />

Not used<br />

Not used<br />

Not used<br />

Not used<br />

Not used<br />

Not used<br />

Not used<br />

0= Whistle Activates L1 (See Bit 4 CV225)<br />

1=Bell Activates L1 (See Bit 4 CV225)<br />

Page 107 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV227<br />

DCC Control Three<br />

CONTROL CVs<br />

Description<br />

This Value Contains Various DCC Control Bits<br />

Values<br />

0-255<br />

Initial Value<br />

3<br />

Related CVs<br />

CV130, CV160<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 1 1<br />

Bit7:<br />

Bit6:<br />

Bit5:<br />

Bit4:<br />

Bit3:<br />

Bit2:<br />

Bit1:<br />

Bit0:<br />

Not used<br />

Not used<br />

Not used<br />

Not used<br />

Not used<br />

Not used<br />

0=Brake Squeal Disabled on Quick Decelerations<br />

1=Brake Squeal Automatic on Quick Decelerations<br />

0=Brake Set and Brake Release Disabled on Throttle<br />

Stop Zero Transitions<br />

1=Brake Set and Brake Release Automatic on Throttle<br />

Stop Zero Transitions<br />

Page 108 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV228<br />

DCC Startup Timer<br />

CONTROL CVs<br />

Description<br />

This Value Contains the DCC Startup Timer<br />

Values<br />

0-255<br />

Initial Value<br />

1<br />

Related CVs<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 1<br />

On power up, the decoder will wait this much time in seconds to<br />

detect the DCC system. If this value is too low, DC mode will start<br />

the system resulting in strange behavior. The initial value is 1 second.<br />

Page 109 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CONTROL CVs<br />

CV229<br />

DCC Extended Consist Lighting<br />

Description<br />

This Value Controls Extended DCC Consist Lighting<br />

Values<br />

0-255<br />

Initial Value<br />

135<br />

Related CVs<br />

CV19, CV21, CV22<br />

Bit 7 Bit 0<br />

1 0 0 0 0 1 1 1<br />

Bit7:<br />

Bit6:<br />

Bit5:<br />

Bit4:<br />

Bit3:<br />

Bit2:<br />

Bit1:<br />

Bit0:<br />

Cab Disabled=0; Cab Enabled=1<br />

Not used<br />

Not used<br />

Not used<br />

Not used<br />

L1 Disabled=0; L1 Enabled=1<br />

Front Light Disabled=0; Front Light Enabled=1<br />

Rear Light Disabled=0; Rear Light Enabled=1<br />

See Consist, a technical discussion<br />

Page 110 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV230<br />

DCC Easy Consist<br />

CONTROL CVs<br />

Description<br />

This Value Allows Convenient DCC Consist Configuration<br />

Values<br />

1,2,3<br />

Initial Value<br />

0<br />

Related CVs<br />

CV19, CV21, CV22, CV229<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 0<br />

The easy consist feature sets the decoder CV19 for consist 60 forward<br />

facing engine. Select 1, 2 or 3 for value to set the consist position.<br />

Values:<br />

0 = Consist Disabled<br />

1 = Front Engine<br />

All consist function keys enabled (CV21, CV22)<br />

All lights except the rear light enabled (CV229)<br />

2 = Middle Engine<br />

All consist function keys except F0, F8 and F9<br />

disabled (CV21, CV22); All lights disabled (CV229)<br />

3 = Rear Engine<br />

All consist function keys except F0, F8 and F9<br />

disabled (CV21, CV22)<br />

Only rear light enabled (CV229)<br />

Page 111 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


The consist may be disabled by setting CV19 to zero or CV230 to<br />

zero. No CV’s may be changed when the consist is addressed. The<br />

engine in a consist must be addressed when modifying its CV. All<br />

function keys are honored by addressing the engine. Additionally,<br />

function keys enabled by CV21 and CV22 are honored by addressing<br />

the consist. Using the Easy Consist feature allows a quick<br />

programming of a basic consist.<br />

Front Engine<br />

All lights are active accept the reverse light. If a change in this<br />

lighting is required, modify CV299 for the appropriate lighting<br />

changes. All functions keys are enable when the consist is addressed.<br />

If a change in active function keys are required, modify CV21 and<br />

CV22.<br />

Middle Engine<br />

All lights are inactive. If a change in this lighting is required, modify<br />

CV299 for the appropriate lighting changes. All functions keys are<br />

disabled except F0 (Headlight), F8 (Mute-Volume) and F9 (Startup)<br />

when the consist is addressed. If a change in active function keys are<br />

required, modify CV21 and CV22.<br />

Rear Engine<br />

Only the reverse light is active. If a change in this lighting is required,<br />

modify CV299 for the appropriate lighting changes. All functions<br />

keys are disabled except F0 (Headlight), F8 (Mute-Volume) and F9<br />

(Startup) when the consist is addressed. If a change in active function<br />

keys are required, modify CV21 and CV22.<br />

See Consist, a technical discussion<br />

Page 112 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CONTROL CVs<br />

CV240<br />

Random Sound Effect Generator Occurrence<br />

Description<br />

This Value Contains the DCC Startup Timer<br />

Values<br />

1-30<br />

Initial Value<br />

24<br />

Related CVs<br />

Bit 7 Bit 0<br />

0 0 0 1 1 0 0 0<br />

This value determines how often random sound effects occur.<br />

Increasing this value decreases the occurrences of random sound<br />

effects.<br />

Page 113 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CV245<br />

General System Controls<br />

CONTROL CVs<br />

Description<br />

This Value Contains General Bits as Defined<br />

Values<br />

0-255<br />

Initial Value<br />

1<br />

Related CVs<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 0 1<br />

These bit value control the following:<br />

D0 – 0=Whistle Alternative Ending Disabled<br />

1=Whistle Alternative Ending Enabled<br />

Page 114 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CONTROL CVs<br />

CV248<br />

Enhanced DC Motor Startup Delay<br />

Description<br />

This Value Contains the Motor Startup Delay<br />

Values<br />

0-63<br />

Initial Value<br />

8<br />

Related CVs<br />

Bit 7 Bit 0<br />

0 0 0 0 1 0 0 0<br />

This value creates a powerup motor delay. Decreasing this value<br />

causes a delay in when the motor receives power. This value allows<br />

closer synchronization between sounds and user actions.<br />

Page 115 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CONTROL CVs<br />

CV249<br />

Enhanced DC Motor Control Momentum<br />

Description<br />

This Value Contains the Motor Momentum<br />

Values<br />

0-255<br />

Initial Value<br />

2<br />

Related CVs<br />

Bit 7 Bit 0<br />

0 0 0 0 0 0 1 0<br />

This value creates a motor delay in responding to track voltage<br />

changes. Increasing this value slows the response to changing track<br />

voltages while decreasing this value increases the response to<br />

changing track voltages. This value allows closer synchronization<br />

between sounds and user actions. Only the motor response is slowed<br />

by this value.<br />

Page 116 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CONTROL CVs<br />

CV250<br />

Enhanced DC Motor Track Voltage Momentum<br />

Description<br />

This Value Contains the Track Voltage Momentum<br />

Values<br />

1-255<br />

Initial Value<br />

10<br />

Related CVs<br />

Bit 7 Bit 0<br />

0 0 0 0 1 0 1 0<br />

This value creates a delay in the digitally filtered track voltage.<br />

Increasing this value slows the response to changing track voltages<br />

while decreasing this value increases the response to changing track<br />

voltages. Sound and motor response varies with the change in this<br />

value.<br />

Page 117 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CONTROL CVs<br />

CV251<br />

Enhanced DC Motor Control Vmax<br />

Description<br />

This Value Contains the Motor Finish Track Voltage<br />

Values<br />

0-255<br />

Initial Value<br />

144<br />

Related CVs<br />

CV 252, CV253<br />

Bit 7 Bit 0<br />

1 0 0 1 0 0 0 0<br />

Vmax is the track voltage that once reached allows 100% track power<br />

to the motor. Increasing Vmax means a higher track voltage is<br />

needed before all track power is supplied to the motor. Decreasing<br />

Vmax means full power to the motor at a lower track voltage.<br />

Note: Vmax must be greater than Vmin.<br />

See Advanced DC Motor Control<br />

Page 118 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CONTROL CVs<br />

CV252<br />

Enhanced DC Motor Control Vmin<br />

Description<br />

This Value Contains the Motor Start Track Voltage<br />

Values<br />

0-255<br />

Initial Value<br />

80<br />

Related CVs<br />

CV 251, CV253<br />

Bit 7 Bit 0<br />

0 1 0 1 0 0 0 0<br />

Vmin defines the track voltage that applies the lowest or starting<br />

motor power. The power applied at this voltage is the Dmin. Valid<br />

values for Vmin is from 0-255. Decreasing Vmin means a higher track<br />

voltage becomes necessary before the train begins to move.<br />

Increasing Vmin means the train begins to move at a lower track<br />

voltage. Vmin and Dmin work together to determine the initial<br />

motor power at the start voltage for train movement.<br />

Note: Vmin must be less than Vmax.<br />

See Advanced DC Motor Control<br />

Page 119 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


CONTROL CVs<br />

CV253<br />

Enhanced DC Motor Control Dmin<br />

Description<br />

This Value Contains the Motor Start Duty Cycle<br />

Values<br />

0-255<br />

Initial Value<br />

50<br />

Related CVs<br />

CV 251, CV252<br />

Bit 7 Bit 0<br />

0 0 1 1 0 0 1 0<br />

Dmin defines the minimal duty cycled responsible for Vmin motor<br />

power. Increasing this value will cause more motor power at Vmin<br />

while decreasing this value causes less motor power at Vmin.<br />

See Advanced DC Motor Control<br />

Page 120 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Advanced DC Motor Control<br />

Dc operation with sounds creates a dilemma. The train usually will start moving at a very low<br />

track voltage, to low to power a loudspeaker with high quality sounds. A higher voltage of<br />

operation for the motor is an acceptable solution. About 6-7 volts is necessary before this sound<br />

system can function, producing loud, high quality sounds, with the motor powered and the train<br />

beginning to move. This advanced motor controller gives acceptable motor control at the<br />

necessary power levels, allowing the sound system to start at a much lower voltage, keeping the<br />

motor from stealing the power from the sound system until enough power exists to move the<br />

train without the sounds degrading or shutting off. Also, more overall power is diverted to the<br />

motor at top speeds. The maximum train speed is higher with this advanced DC motor<br />

controller.<br />

The DC motor controller may be altered by changing the power curve. CV251, CV252 and<br />

CV253 control the slope, intercept and initial motor power. Altering these values changes the<br />

trains startup behavior relative to track voltage and at what voltage full track power is applied to<br />

the motor.<br />

Vmin<br />

Vmin defines the track voltage that applies the lowest or starting motor power. Valid values for<br />

Vmin is from 0-255. The distance between Vmin and Vmax (Vmax > Vmin) distributes motor<br />

power from Dmin (Applied Duty Cycle) at Vmin until Vmax where 100% of the power from the<br />

track is applied.<br />

Note: Vmin < Vmax. Too low a value for Vmin may cause the sound unit to reset when<br />

power is supplied to the motor.<br />

Vmax<br />

Vmax is the track voltage that once reached allows 100% track power to the motor. Valid values<br />

for Vmax is from 0-255. Increasing Vmax means a higher track voltage is needed before all track<br />

power is supplied to the motor. Decreasing Vmax means full power to the motor at a lower track<br />

voltage.<br />

Note: Vmax > Vin. Too high a value for Vmax may not allow the train to reach full speed.<br />

Dmin<br />

Dmin defines the minimal duty cycled responsible for Vmin motor power. Valid values are from<br />

1 to 63. The initial value is 44. Increasing this value will cause more motor power at Vmin<br />

while decreasing this value causes less motor power at Vmin.<br />

Note: Too high a value for Dmin may cause the sound unit to reset when power is supplied<br />

to the motor<br />

Page 121 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Advanced DC Motor Control<br />

Figure one illustrates a motor connected directly to track power and a motor connected to the<br />

advanced motor controller. The sound unit supplies full sound volume at about 5.5 volts. Motor<br />

power is supplied around 6 volts. Between 6 volts and 12 volts, the sound unit monitors the track<br />

voltage and proportionately increase or decreases the motor power as noted by the slope of the<br />

enhanced curve in figure one. At about 12 volts, all power is applied to the motor. The train<br />

motor is now for all practically purposes, connected directly to the track. Note that 100% power<br />

is not applied. The loss is due to the power control device. You will note that the maximum<br />

train speed will be faster with the enhanced DC motor controller than most DC decoders. This<br />

loss illustrated in the curve is much less with the enhanced DC motor controller.<br />

Motor Power<br />

Advanced DC Motor Controller<br />

Power Curve<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

Normal<br />

Enhanced<br />

2 4 6 8 10 12 14 16 18<br />

Track Voltage<br />

Figure 1<br />

Page 122 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


SYSTEM CVs<br />

CV Description Initial Yours<br />

1 Primary Address 3<br />

7 Manufacturer Version ?<br />

8 Manufacturer ID 38<br />

15 Unlock ID Code 0<br />

16 Lock ID Number 0<br />

17 Extended Address MSB 192<br />

18 Extended Address LSB 128<br />

19 Consist Address 0<br />

21 Consist Functions Type 0 255<br />

22 Consist Functions Type1 255<br />

29 Configuration Bits 2<br />

Page 123 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


FUNCTION CVs<br />

CV Description Initial Yours<br />

33 F0(f) (Front Lamp) 1<br />

34 F0(r) (Rear Lamp) 2<br />

35 F1 (Bell) 16<br />

36 F2 (Whistle) 4<br />

37 F3 (Couple/Uncouple) 32<br />

38 F4 (Air Pump) 8<br />

39 F5 (Blown/Increase Chuff Magnitude) 16<br />

40 F6 (Water Fill/Decrease Chuff Magnitude) 32<br />

41 F7 (L1 Visual Effects) 64<br />

42 F8 (Master Analog Volume) 128<br />

43 F9 (Shutdown and Startup) 16<br />

44 F10 (Shovel Coal) 32<br />

45 F11 (Water Injector) 64<br />

46 F12 (Brake Set/Release) 128<br />

Page 124 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Sound CVs<br />

CV Description Initial Yours<br />

130 Master Volume Sound Increment 2<br />

131 Analog Sound Unit Startup Voltage 56<br />

132 Analog Sound Unit Shutdown Voltage 54<br />

133 Sound Unit Master Volume 15<br />

135 Whistle Volume 100<br />

136 Bell Volume 100<br />

137 <strong>Steam</strong> Volume 100<br />

138 Horn Volume 100<br />

140 Couple Volume 100<br />

141 Uncouple Volume 100<br />

143 Air Pump Volume 100<br />

144 Blow Down Volume 100<br />

145 <strong>Steam</strong> Cock Volume 100<br />

146 Brake Set Volume 100<br />

147 Brake Release Volume 100<br />

148 Pop Off Valve Volume 100<br />

149 Blower Volume 100<br />

150 Dynamo Volume 100<br />

151 Brake Squeal Volume 100<br />

152 Shovel Coal Volume 100<br />

153 Water Fill Volume 100<br />

154 Water Injector Volume 100<br />

155 Chuff Volume 100<br />

Page 125 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


LIGHTING CVs<br />

CV Description Initial Yours<br />

159 System Lighting 0<br />

160 L1 Light Definition Varies<br />

161 L1 Parameter 1 Varies<br />

162 L1 Parameter 2 Varies<br />

163 L1 Parameter 3 Varies<br />

164 L1 Parameter 4 Varies<br />

Page 126 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Setup CVs<br />

CV Description Initial Yours<br />

180 Bell Ring Interval Varies<br />

181 Whistle Fade In Varies<br />

182 Whistle Fade Out Varies<br />

183 Whistle Fade In Level Varies<br />

184 Analog Brake Control 64<br />

185 DCC Brake Control 20<br />

186 DCC Brake Timer 1<br />

187 DCC Uncouple Throttle Stop 3<br />

188 Pitch Shift 128<br />

190 Analog Sound Setup x<br />

191 Analog Brake Set Voltage 70<br />

192 Analog Brake Release Voltage 77<br />

196 <strong>Steam</strong> Cock Chuffs Event Count 1<br />

197 Rod Knock Chuffs Event Count 2<br />

198 Rod Knock Volume 80<br />

199 Chuff Magnitude Increase Volume 255<br />

200 DCC Throttle Magnitude Increase 1<br />

201 DCC Throttle Magnitude Decrease 1<br />

202 DC Track Change Magnitude Increase 160<br />

203 DC Track Change Magnitude Decrease 160<br />

204 F5 Chuff Magnitude Change Increment 32<br />

205 F6 Chuff Magnitude Change Decrement 32<br />

Page 127 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Setup CVs<br />

208 DCC Cab Light Throttle Stop 3<br />

209 DCC Brake Set Throttle Stop 0<br />

210 DCC Brake Release Throttle Stop 2<br />

Page 128 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Control CVs<br />

CV Description Initial Yours<br />

220 Analog Control One 3<br />

221 Analog Control Two 0<br />

222 Analog AUX Select for DCMaster 0<br />

223 DC Extended Consist Control 135<br />

224 DC Easy Consist 0<br />

225 DCC Control One 3<br />

226 DCC Control Two 0<br />

227 DCC Control Three 3<br />

228 DCC Start Up Timer 1<br />

229 DCC Extended Consist Lighting 135<br />

230 DCC Easy Consist 0<br />

240 Random Sound Generator Occurrence 24<br />

245 General System Controls 1<br />

248 Enhanced DC Motor Startup Delay 8<br />

249 Enhanced DC Motor Control Momentum 2<br />

250 Enhanced DC Motor Track Voltage Momentum 10<br />

251 Enhanced DC Motor Control Vmax 144<br />

252 Enhanced DC Motor Control Vmin 80<br />

253 Enhanced DC Motor Control Dmin 50<br />

Page 129 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


DCC CVs<br />

CV Description Initial Yours<br />

1 Primary Address 3<br />

7 Manufacturer Version ?<br />

8 Manufacturer ID 38<br />

15 Unlock ID Code 0<br />

16 Lock ID Number 0<br />

17 Extended Address MSB 192<br />

18 Extended Address LSB 128<br />

19 Consist Address 0<br />

21 Consist Functions Type 0 255<br />

22 Consist Functions Type1 255<br />

29 Configuration Bits 2<br />

33 F0(f) (Front Lamp) 1<br />

34 F0(r) (Rear Lamp) 2<br />

35 F1 (Bell) 16<br />

36 F2 (Whistle) 4<br />

37 F3 (Couple/Uncouple) 32<br />

38 F4 (Air Pump) 8<br />

39 F5 (Blown/Increase Chuff Magnitude) 16<br />

40 F6 (Water Fill/Decrease Chuff Magnitude) 32<br />

41 F7 (L1 Visual Effects) 64<br />

42 F8 (Master Analog Volume) 128<br />

43 F9 (Shutdown and Startup) 16<br />

44 F10 (Shovel Coal) 32<br />

45 F11 (Water Injector) 64<br />

46 F12 (Brake Set/Release) 128<br />

Page 130 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


DCC CVs<br />

CV Description Initial Yours<br />

130 Master Volume Sound Increment 2<br />

131 Analog Sound Unit Startup Voltage 56<br />

132 Analog Sound Unit Shutdown Voltage 54<br />

133 Sound Unit Master Volume 15<br />

135 Whistle Volume 100<br />

136 Bell Volume 100<br />

137 <strong>Steam</strong> Volume 100<br />

138 Horn Volume 100<br />

140 Couple Volume 100<br />

141 Uncouple Volume 100<br />

143 Air Pump Volume 100<br />

144 Blow Down Volume 100<br />

145 <strong>Steam</strong> Cock Volume 100<br />

146 Brake Set Volume 100<br />

147 Brake Release Volume 100<br />

148 Pop Off Valve Volume 100<br />

149 Blower Volume 100<br />

150 Dynamo Volume 100<br />

151 Brake Squeal Volume 100<br />

152 Shovel Coal Volume 100<br />

153 Water Fill Volume 100<br />

154 Water Injector Volume 100<br />

155 Chuff Volume 100<br />

Page 131 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


DCC CVs<br />

CV Description Initial Yours<br />

159 System Lighting 0<br />

160 L1 Light Definition Varies<br />

161 L1 Parameter 1 Varies<br />

162 L1 Parameter 2 Varies<br />

163 L1 Parameter 3 Varies<br />

164 L1 Parameter 4 Varies<br />

180 Bell Ring Interval Varies<br />

181 Whistle Fade In Varies<br />

182 Whistle Fade Out Varies<br />

183 Whistle Fade In Level Varies<br />

185 DCC Brake Control 20<br />

186 DCC Brake Timer 1<br />

187 DCC Uncouple Throttle Stop 3<br />

188 Pitch Shift 128<br />

196 <strong>Steam</strong> Cock Chuffs Event Count 1<br />

197 Rod Knock Chuffs Event Count 2<br />

198 Rod Knock Volume 80<br />

199 Chuff Magnitude Increase Volume 255<br />

200 DCC Throttle Magnitude Increase 1<br />

201 DCC Throttle Magnitude Decrease 1<br />

202 DC Track Change Magnitude Increase 160<br />

203 DC Track Change Magnitude Decrease 160<br />

204 F5 Chuff Magnitude Change Increment 32<br />

205 F6 Chuff Magnitude Change Decrement 32<br />

Page 132 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


DCC CVs<br />

208 DCC Cab Light Throttle Stop 3<br />

209 DCC Brake Set Throttle Stop 0<br />

210 DCC Brake Release Throttle Stop 2<br />

225 DCC Control One 3<br />

226 DCC Control Two 0<br />

227 DCC Control Three 3<br />

228 DCC Start Up Timer 1<br />

229 DCC Extended Consist Lighting 135<br />

230 DCC Easy Consist 0<br />

240 Random Sound Generator Occurrence 24<br />

245 General System Controls 1<br />

Page 133 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


DC CVs<br />

CV Description Initial Yours<br />

15 Unlock ID Code 0<br />

16 Lock ID Number 0<br />

19 Consist Address 0<br />

29 Configuration Bits 2<br />

130 Master Volume Sound Increment 2<br />

131 Analog Sound Unit Startup Voltage 56<br />

132 Analog Sound Unit Shutdown Voltage 54<br />

133 Sound Unit Master Volume 15<br />

135 Whistle Volume 100<br />

136 Bell Volume 100<br />

137 <strong>Steam</strong> Volume 100<br />

138 Horn Volume 100<br />

140 Couple Volume 100<br />

141 Uncouple Volume 100<br />

143 Air Pump Volume 100<br />

144 Blow Down Volume 100<br />

145 <strong>Steam</strong> Cock Volume 100<br />

146 Brake Set Volume 100<br />

147 Brake Release Volume 100<br />

148 Pop Off Valve Volume 100<br />

149 Blower Volume 100<br />

150 Dynamo Volume 100<br />

151 Brake Squeal Volume 100<br />

152 Shovel Coal Volume 100<br />

153 Water Fill Volume 100<br />

Page 134 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


DC CVs<br />

CV Description Initial Yours<br />

154 Water Injector Volume 100<br />

155 Chuff Volume 100<br />

159 System Lighting 0<br />

160 L1 Light Definition Varies<br />

161 L1 Parameter 1 Varies<br />

162 L1 Parameter 2 Varies<br />

163 L1 Parameter 3 Varies<br />

164 L1 Parameter 4 Varies<br />

180 Bell Ring Interval Varies<br />

181 Whistle Fade In Varies<br />

182 Whistle Fade Out Varies<br />

183 Whistle Fade In Level Varies<br />

184 Analog Brake Control 64<br />

188 Pitch Shift 128<br />

190 Analog Sound Setup x<br />

191 Analog Brake Set Voltage 70<br />

192 Analog Brake Release Voltage 77<br />

196 <strong>Steam</strong> Cock Chuffs Event Count 1<br />

197 Rod Knock Chuffs Event Count 2<br />

198 Rod Knock Volume 80<br />

199 Chuff Magnitude Increase Volume 255<br />

202 DC Track Change Magnitude Increase 160<br />

203 DC Track Change Magnitude Decrease 160<br />

220 Analog Control One 3<br />

221 Analog Control Two 0<br />

Page 135 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


DC CVs<br />

222 Analog AUX Select for DCMaster 0<br />

223 DC Extended Consist Control 135<br />

224 DC Easy Consist 0<br />

240 Random Sound Generator Occurrence 24<br />

245 General System Controls 1<br />

248 Enhanced DC Motor Startup Delay 8<br />

249 Enhanced DC Motor Control Momentum 2<br />

250 Enhanced DC Motor Track Voltage Momentum 10<br />

251 Enhanced DC Motor Control Vmax 144<br />

252 Enhanced DC Motor Control Vmin 80<br />

253 Enhanced DC Motor Control Dmin 50<br />

Page 136 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Decimal to Binary Primer<br />

Setting CV’s<br />

Setting the CV’s requires knowledge of conversion between binary<br />

and decimal. The following examples demonstrates the conversion<br />

process from binary to decimal after determining which bits in a CV<br />

need to be “1” and which needs to be “0”. The tables are also useful<br />

for converting binary to decimal.<br />

Reading CV’s<br />

The tables are also useful for converting decimal to binary when<br />

reading the CV’s in service mode. After reading the CV, use the<br />

tables to determine which bits are “1” and which bits are “0”. Once<br />

the bit patterns are identified, find the CV in this manual to<br />

determine what functions are controlled by the bits.<br />

Bit 7 Bit 0<br />

2 7 2 6 2 5 2 4 2 3 2 2 2 1 2 0<br />

128 64 32 16 8 4 2 1<br />

Consider a binary number 10001011<br />

128+0+0+0+8+0+2+1=139<br />

Consider a binary number 00011101<br />

0+0+0+16+8+4+0+1=29<br />

CVxx read is 39. Table lookup is: 00100111<br />

Page 137 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


Page 138 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00<br />

Decimal to Hexadecimal Conversion<br />

Dec Hex Oct Bin<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

000<br />

001<br />

002<br />

003<br />

004<br />

005<br />

006<br />

007<br />

010<br />

011<br />

012<br />

013<br />

014<br />

015<br />

016<br />

017<br />

00000000<br />

00000001<br />

00000010<br />

00000011<br />

00000100<br />

00000101<br />

00000110<br />

00000111<br />

00001000<br />

00001001<br />

00001010<br />

00001011<br />

00001100<br />

00001101<br />

00001110<br />

00001111<br />

Dec Hex Oct Bin<br />

16<br />

17<br />

18<br />

19<br />

20<br />

21<br />

22<br />

23<br />

24<br />

25<br />

26<br />

27<br />

28<br />

29<br />

30<br />

31<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

1A<br />

1B<br />

1C<br />

1D<br />

1E<br />

1F<br />

020<br />

021<br />

022<br />

023<br />

024<br />

025<br />

026<br />

027<br />

030<br />

031<br />

032<br />

033<br />

034<br />

035<br />

036<br />

037<br />

00010000<br />

00010001<br />

00010010<br />

00010011<br />

00010100<br />

00010101<br />

00010110<br />

00010111<br />

00011000<br />

00011001<br />

00011010<br />

00011011<br />

00011100<br />

00011101<br />

00011110<br />

00011111<br />

Dec Hex Oct Bin<br />

32<br />

33<br />

34<br />

35<br />

36<br />

37<br />

38<br />

39<br />

40<br />

41<br />

42<br />

43<br />

44<br />

45<br />

46<br />

47<br />

20<br />

21<br />

22<br />

23<br />

24<br />

25<br />

26<br />

27<br />

28<br />

29<br />

2A<br />

2B<br />

2C<br />

2D<br />

2E<br />

2F<br />

040<br />

041<br />

042<br />

043<br />

044<br />

045<br />

046<br />

047<br />

050<br />

051<br />

052<br />

053<br />

054<br />

055<br />

056<br />

057<br />

00100000<br />

00100001<br />

00100010<br />

00100011<br />

00100100<br />

00100101<br />

00100110<br />

00100111<br />

00101000<br />

00101001<br />

00101010<br />

00101011<br />

00101100<br />

00101101<br />

00101110<br />

00101111<br />

Dec Hex Oct Bin<br />

48<br />

49<br />

50<br />

51<br />

52<br />

53<br />

54<br />

55<br />

56<br />

57<br />

58<br />

59<br />

60<br />

61<br />

62<br />

63<br />

30<br />

31<br />

32<br />

33<br />

34<br />

35<br />

36<br />

37<br />

38<br />

39<br />

3A<br />

3B<br />

3C<br />

3D<br />

3E<br />

3F<br />

060<br />

061<br />

062<br />

063<br />

064<br />

065<br />

066<br />

067<br />

070<br />

071<br />

072<br />

073<br />

074<br />

075<br />

076<br />

077<br />

00110000<br />

00110001<br />

00110010<br />

00110011<br />

00110100<br />

00110101<br />

00110110<br />

00110111<br />

00111000<br />

00111001<br />

00111010<br />

00111011<br />

00111100<br />

00111101<br />

00111110<br />

00111111<br />

Dec Hex Oct Bin<br />

64<br />

65<br />

66<br />

67<br />

68<br />

69<br />

70<br />

71<br />

72<br />

73<br />

74<br />

75<br />

76<br />

77<br />

78<br />

79<br />

40<br />

41<br />

42<br />

43<br />

44<br />

45<br />

46<br />

47<br />

48<br />

49<br />

4A<br />

4B<br />

4C<br />

4D<br />

4E<br />

4F<br />

100<br />

101<br />

102<br />

103<br />

104<br />

105<br />

106<br />

107<br />

110<br />

111<br />

112<br />

113<br />

114<br />

115<br />

116<br />

117<br />

01000000<br />

01000001<br />

01000010<br />

01000011<br />

01000100<br />

01000101<br />

01000110<br />

01000111<br />

01001000<br />

01001001<br />

01001010<br />

01001011<br />

01001100<br />

01001101<br />

01001110<br />

01001111<br />

Dec Hex Oct Bin<br />

80<br />

81<br />

82<br />

83<br />

84<br />

85<br />

86<br />

87<br />

88<br />

89<br />

90<br />

91<br />

92<br />

93<br />

94<br />

95<br />

50<br />

51<br />

52<br />

53<br />

54<br />

55<br />

56<br />

57<br />

58<br />

59<br />

5A<br />

5B<br />

5C<br />

5D<br />

5E<br />

5F<br />

120<br />

121<br />

122<br />

123<br />

124<br />

125<br />

126<br />

127<br />

130<br />

131<br />

132<br />

133<br />

134<br />

135<br />

136<br />

137<br />

01010000<br />

01010001<br />

01010010<br />

01010011<br />

01010100<br />

01010101<br />

01010110<br />

01010111<br />

01011000<br />

01011001<br />

01011010<br />

01011011<br />

01011100<br />

01011101<br />

01011110<br />

01011111


Page 139 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00<br />

Decimal to Hexadecimal Conversion<br />

Dec Hex Oct Bin<br />

112<br />

113<br />

114<br />

115<br />

116<br />

117<br />

118<br />

119<br />

120<br />

121<br />

122<br />

123<br />

124<br />

125<br />

126<br />

127<br />

70<br />

71<br />

72<br />

73<br />

74<br />

75<br />

76<br />

77<br />

78<br />

79<br />

7A<br />

7B<br />

7C<br />

7D<br />

7E<br />

7F<br />

160<br />

161<br />

162<br />

163<br />

164<br />

165<br />

166<br />

167<br />

170<br />

171<br />

172<br />

173<br />

174<br />

175<br />

176<br />

177<br />

01110000<br />

01110001<br />

01110010<br />

01110011<br />

01110100<br />

01110101<br />

01110110<br />

01110111<br />

01111000<br />

01111001<br />

01111010<br />

01111011<br />

01111100<br />

01111101<br />

01111110<br />

01111111<br />

Dec Hex Oct Bin<br />

128<br />

129<br />

130<br />

131<br />

132<br />

133<br />

134<br />

135<br />

136<br />

137<br />

138<br />

139<br />

140<br />

141<br />

142<br />

143<br />

80<br />

81<br />

82<br />

83<br />

84<br />

85<br />

86<br />

87<br />

88<br />

89<br />

8A<br />

8B<br />

8C<br />

8D<br />

8E<br />

8F<br />

200<br />

201<br />

202<br />

203<br />

204<br />

205<br />

206<br />

207<br />

210<br />

211<br />

212<br />

213<br />

214<br />

215<br />

216<br />

217<br />

10000000<br />

10000001<br />

10000010<br />

10000011<br />

10000100<br />

10000101<br />

10000110<br />

10000111<br />

10001000<br />

10001001<br />

10001010<br />

10001011<br />

10001100<br />

10001101<br />

10001110<br />

10001111<br />

Dec Hex Oct Bin<br />

96<br />

97<br />

98<br />

99<br />

100<br />

101<br />

102<br />

103<br />

104<br />

105<br />

106<br />

107<br />

108<br />

109<br />

110<br />

111<br />

60<br />

61<br />

62<br />

63<br />

64<br />

65<br />

66<br />

67<br />

68<br />

69<br />

6A<br />

6B<br />

6C<br />

6D<br />

6E<br />

6F<br />

140<br />

141<br />

142<br />

143<br />

144<br />

145<br />

146<br />

147<br />

150<br />

151<br />

152<br />

153<br />

154<br />

155<br />

156<br />

157<br />

01100000<br />

01100001<br />

01100010<br />

01100011<br />

01100100<br />

01100101<br />

01100110<br />

01100111<br />

01101000<br />

01101001<br />

01101010<br />

01101011<br />

01101100<br />

01101101<br />

01101110<br />

01101111<br />

Dec Hex Oct Bin<br />

144<br />

145<br />

146<br />

147<br />

148<br />

149<br />

150<br />

151<br />

152<br />

153<br />

154<br />

155<br />

156<br />

157<br />

158<br />

159<br />

90<br />

91<br />

92<br />

93<br />

94<br />

95<br />

96<br />

97<br />

98<br />

99<br />

9A<br />

9B<br />

9C<br />

9D<br />

9E<br />

9F<br />

220<br />

221<br />

222<br />

223<br />

224<br />

225<br />

226<br />

227<br />

230<br />

231<br />

232<br />

233<br />

234<br />

235<br />

236<br />

237<br />

10010000<br />

10010001<br />

10010010<br />

10010011<br />

10010100<br />

10010101<br />

10010110<br />

10010111<br />

10011000<br />

10011001<br />

10011010<br />

10011011<br />

10011100<br />

10011101<br />

10011110<br />

10011111<br />

Dec Hex Oct Bin<br />

160<br />

161<br />

162<br />

163<br />

164<br />

165<br />

166<br />

167<br />

168<br />

169<br />

170<br />

171<br />

172<br />

173<br />

174<br />

175<br />

A0<br />

A1<br />

A2<br />

A3<br />

A4<br />

A5<br />

A6<br />

A7<br />

A8<br />

A9<br />

AA<br />

AB<br />

AC<br />

AD<br />

AE<br />

AF<br />

240<br />

241<br />

242<br />

243<br />

244<br />

245<br />

246<br />

247<br />

250<br />

251<br />

252<br />

253<br />

254<br />

255<br />

256<br />

257<br />

10100000<br />

10100001<br />

10100010<br />

10100011<br />

10100100<br />

10100101<br />

10100110<br />

10100111<br />

10101000<br />

10101001<br />

10101010<br />

10101011<br />

10101100<br />

10101101<br />

10101110<br />

10101111<br />

Dec Hex Oct Bin<br />

176<br />

177<br />

178<br />

179<br />

180<br />

181<br />

182<br />

183<br />

184<br />

185<br />

186<br />

187<br />

188<br />

189<br />

190<br />

191<br />

B0<br />

B1<br />

B2<br />

B3<br />

B4<br />

B5<br />

B6<br />

B7<br />

B8<br />

B9<br />

BA<br />

BB<br />

BC<br />

BD<br />

BE<br />

BF<br />

260<br />

261<br />

262<br />

263<br />

264<br />

265<br />

266<br />

267<br />

270<br />

271<br />

272<br />

273<br />

274<br />

275<br />

276<br />

277<br />

10110000<br />

10110001<br />

10110010<br />

10110011<br />

10110100<br />

10110101<br />

10110110<br />

10110111<br />

10111000<br />

10111001<br />

10111010<br />

10111011<br />

10111100<br />

10111101<br />

10111110<br />

10111111


Decimal to Hexadecimal Conversion<br />

Dec Hex Oct Bin<br />

Dec Hex Oct Bin<br />

Dec Hex Oct Bin<br />

192<br />

193<br />

194<br />

195<br />

196<br />

197<br />

198<br />

199<br />

200<br />

201<br />

202<br />

203<br />

204<br />

205<br />

206<br />

207<br />

C0<br />

C1<br />

C2<br />

C3<br />

C4<br />

C5<br />

C6<br />

C7<br />

C8<br />

C9<br />

CA<br />

CB<br />

CC<br />

CD<br />

CE<br />

CF<br />

300<br />

301<br />

302<br />

303<br />

304<br />

305<br />

306<br />

307<br />

310<br />

311<br />

312<br />

313<br />

314<br />

315<br />

316<br />

317<br />

11000000<br />

11000001<br />

11000010<br />

11000011<br />

11000100<br />

11000101<br />

11000110<br />

11000111<br />

11001000<br />

11001001<br />

11001010<br />

11001011<br />

11001100<br />

11001101<br />

11001110<br />

11001111<br />

208<br />

209<br />

210<br />

211<br />

212<br />

213<br />

214<br />

215<br />

216<br />

217<br />

218<br />

219<br />

220<br />

221<br />

222<br />

223<br />

D0<br />

D1<br />

D2<br />

D3<br />

D4<br />

D5<br />

D6<br />

D7<br />

D8<br />

D9<br />

DA<br />

DB<br />

DC<br />

DD<br />

DE<br />

DF<br />

320<br />

321<br />

322<br />

323<br />

324<br />

325<br />

326<br />

327<br />

330<br />

331<br />

332<br />

333<br />

334<br />

335<br />

336<br />

337<br />

11010000<br />

11010001<br />

11010010<br />

11010011<br />

11010100<br />

11010101<br />

11010110<br />

11010111<br />

11011000<br />

11011001<br />

11011010<br />

11011011<br />

11011100<br />

11011101<br />

11011110<br />

11011111<br />

224<br />

225<br />

226<br />

227<br />

228<br />

229<br />

230<br />

231<br />

232<br />

233<br />

234<br />

235<br />

236<br />

237<br />

238<br />

239<br />

E0<br />

E1<br />

E2<br />

E3<br />

E4<br />

E5<br />

E6<br />

E7<br />

E8<br />

E9<br />

EA<br />

EB<br />

EC<br />

ED<br />

EE<br />

EF<br />

340<br />

341<br />

342<br />

343<br />

344<br />

345<br />

346<br />

347<br />

350<br />

351<br />

352<br />

353<br />

354<br />

355<br />

356<br />

357<br />

11100000<br />

11100001<br />

11100010<br />

11100011<br />

11100100<br />

11100101<br />

11100110<br />

11100111<br />

11101000<br />

11101001<br />

11101010<br />

11101011<br />

11101100<br />

11101101<br />

11101110<br />

11101111<br />

Dec Hex Oct Bin<br />

240<br />

241<br />

242<br />

243<br />

244<br />

245<br />

246<br />

247<br />

248<br />

249<br />

250<br />

251<br />

252<br />

253<br />

254<br />

255<br />

F0<br />

F1<br />

F2<br />

F3<br />

F4<br />

F5<br />

F6<br />

F7<br />

F8<br />

F9<br />

FA<br />

FB<br />

FC<br />

FD<br />

FE<br />

FF<br />

360<br />

361<br />

362<br />

363<br />

364<br />

365<br />

366<br />

367<br />

370<br />

371<br />

372<br />

373<br />

374<br />

375<br />

376<br />

377<br />

11110000<br />

11110001<br />

11110010<br />

11110011<br />

11110100<br />

11110101<br />

11110110<br />

11110111<br />

11111000<br />

11111001<br />

11111010<br />

11111011<br />

11111100<br />

11111101<br />

11111110<br />

11111111<br />

Page 140 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


DCC Function Keys<br />

Function Key<br />

F0<br />

F1<br />

F2<br />

F3<br />

F4<br />

F5<br />

F6<br />

F7<br />

F8<br />

F9<br />

F10<br />

F11<br />

F12<br />

Description<br />

Front/Rear Lighting(Dynamo On/Off)<br />

Bell<br />

Whistle<br />

Not Moving: Arm Coil Uncouple<br />

Moving: Plays Coil Couple<br />

Air Pump<br />

Not Moving: Water Fill<br />

Moving: Increase Chuff Magnitude<br />

Not Moving: Blow Down<br />

Moving: Decrease Chuff Magnitude<br />

L1 Control<br />

Double Press: System Volume Up or Down<br />

Single Press: All Sounds Muted Except Horn/Bell<br />

Startup or Shutdown<br />

Shovel Coal<br />

Water Injector<br />

Throttle Stop Zero: Brake Set<br />

Throttle Stop One: Brake Release<br />

Page 141 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00


DCMaster Control<br />

Key<br />

Bell<br />

Horn<br />

Aux<br />

Vol<br />

Bell<br />

Horn<br />

Description<br />

AUX Function Select:<br />

Air Pump<br />

Coupler Sound Effects<br />

Front/Rear Light Control<br />

L1 Light Control<br />

Double Press: System Volume Up or Down<br />

Single Press: All Sounds Muted Except Horn/Bell<br />

Page 142 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!