BlueLine Steam BlueLine Steam Technical ... - Ulrich Models
BlueLine Steam BlueLine Steam Technical ... - Ulrich Models
BlueLine Steam BlueLine Steam Technical ... - Ulrich Models
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>BlueLine</strong> <strong>Steam</strong><br />
<strong>Technical</strong> Reference Manual<br />
Release 1.00<br />
Page 1 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
INTRODUCTION<br />
The M1 sound unit is a multi-function DCC decoder that supports the<br />
following:<br />
DCC Characteristics<br />
• 14 bit addressing<br />
• 7 bit addressing (1-127)<br />
• Enhanced Lighting Control<br />
• Advanced Sound Support<br />
• Consist Support<br />
• 14, 28 and 128 speed steps<br />
• Support for F0—F12 including remapping<br />
• Operations mode support for all CV settings<br />
• Configuration Variable Access Acknowledgement in Service mode<br />
• Direct Mode support in Service Mode including Write and Verify<br />
DC characteristics<br />
• DCMaster uses Direct Mode for CV Programming<br />
• All CV’s programmable<br />
• Enhanced Lighting Control<br />
• Advanced Sound Support<br />
• Consist Support<br />
• Enhanced Motor Control<br />
• Selectable DCMaster AUX Control<br />
Page 2 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SYSTEM CVs<br />
CV1<br />
Primary Address<br />
Description<br />
The Decoders Primary Address is Stored Here<br />
Values<br />
Bits 0-6 contain an address with a value between 1 and 127<br />
Initial Value<br />
3 (Engine 3)<br />
Related CVs<br />
CV29 Bit 5<br />
CV17, CV18, CV19, CV20<br />
Bit 7 Bit 0<br />
0 A6 A5 A4 A3 A2 A1 A0<br />
The decoder responds to all valid commands if the address matches<br />
the value in CV1 and CV29 Bit 5 is set to 0.<br />
Programming CV1 will program CV19 (Consists Address) to zero<br />
and programs CV29 Bit 5 to 0 (Extended Addressing Off).<br />
Page 3 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SYSTEM CVs<br />
CV7<br />
Manufacturer Version Number<br />
Description<br />
The Decoders Read Only Type/Revision is Stored Here<br />
Values<br />
Initial Value<br />
Related CVs<br />
None<br />
Bit 7 Bit 0<br />
D7 D6 D5 D4 D3 D2 D1 D0<br />
This value cannot be modified.<br />
000xxxxx = Diesel and xxxxx is the revision.<br />
001xxxxx = <strong>Steam</strong> and xxxxx is the revision.<br />
Page 4 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SYSTEM CVs<br />
CV8<br />
Manufacturer ID<br />
Description<br />
The Decoders NMRA Assigned Number is Stored Here. Broadway<br />
Limited is assigned ID 38.<br />
Values<br />
Initial Value<br />
38<br />
Related CVs<br />
None<br />
Bit 7 Bit 0<br />
0 0 1 0 0 1 1 0<br />
Writing an 8 to this location will reset all CVs back to their original<br />
manufactured values. This value itself cannot be modified.<br />
Page 5 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SYSTEM CVs<br />
CV15<br />
Unlock ID Code<br />
Description<br />
The Number is the Unlock ID<br />
Values<br />
0-7<br />
Initial Value<br />
0<br />
Related CVs<br />
None<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 0<br />
Factory new units have the unlock id code and the lock id number set<br />
to zero, allowing normal programming of all CV’s. Users wishing to<br />
lock this decoder may start by programming CV16 with a<br />
recommended value of 2. Now, unlock the decoder for CV updates<br />
by writing 2 to CV15. Once all programming is completed, write a<br />
value of 0 to CV15. Now the decoder is locked. Please note once the<br />
decoder is locked, no CV’s other than CV1 or CV15 may be read or<br />
changed. The factory reset is also disabled.<br />
Page 6 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SYSTEM CVs<br />
CV16<br />
Lock ID Number<br />
Description<br />
This Number Identifies this Single Decoder.<br />
Values<br />
0-7<br />
Initial Value<br />
0<br />
Related CVs<br />
None<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 0<br />
This value may only be changed when CV15 equals CV16. CV15<br />
may always be read. The following definitions may be used when<br />
programming this number:<br />
Lock Disabled 0<br />
Motor Decoder 1<br />
Sound Decoder 2<br />
Function Decoder 3<br />
If this feature is use, the recommendation is to program a 2 for value.<br />
Please note once the decoder is locked, no CV’s other than CV1 or<br />
CV15 may be read or changed. The factory reset is also disabled.<br />
Page 7 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV17 and CV18<br />
Extended Address<br />
SYSTEM CVs<br />
Description<br />
This Value Contains the Decoders Extended Address and is Valid<br />
Only if CV29 Bit 5 is 1<br />
Values<br />
Values From 0 to 10239 are Valid<br />
Initial Value<br />
1100 0000 1000 0000 (Engine 128)<br />
Related CVs<br />
CV29 Bit 5<br />
Bit 15 Bit 8<br />
1 1 A13 A12 A11 A10 A9 A8<br />
CV17 Extended Address MSB<br />
Bit 7 Bit 0<br />
A7 A6 A5 A4 A3 A2 A1 A0<br />
CV18 Extended Address LSB<br />
CV17 Valid Values are 1100 0000 thru 1110 0111<br />
CV18 Valid Values are 0000 0000 thru 0000 0000<br />
Page 8 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SYSTEM CVs<br />
CV19<br />
Consist Address<br />
Description<br />
The Decoders Consist Address is Stored Here<br />
Values<br />
0-255<br />
Initial Value<br />
0<br />
Related CVs<br />
CV21, CV22, CV224, CV229<br />
Bit 7 Bit 0<br />
Dir A6 A5 A4 A3 A2 A1 A0<br />
Consist valid address are 1-127 or A6-A0 where a value of 0 breaks<br />
the consist and all received consist commands are ignored. The Dir<br />
bit selects normal or reverse directional lighting. If Dir=0 than normal<br />
directional lighting is selected. If Dir=1 than reverse directional<br />
lighting is selected. Reverse directional lighting is useful when the<br />
engine is oriented backwards in the consist.<br />
See Consist, a technical discussion.<br />
Page 9 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV21<br />
Consist Functions Type 0<br />
SYSTEM CVs<br />
Description<br />
Determines Which Functions (F1-F8) are Allowed in the Consist<br />
Values<br />
0-255<br />
Initial Value<br />
255<br />
Related CVs<br />
CV19, CV22, CV223, CV229<br />
Bit 7 Bit 0<br />
F8 F7 F6 F5 F4 F3 F2 F1<br />
The decoder responds to all functions that have a “1” set in this CV<br />
once a consist is configured. A consist is configured by CV19<br />
programmed to a value from 1-127. A value of 0 breaks the consist.<br />
See CV19. This CV is used to configure the engine for a front, middle<br />
or end in the consist.<br />
An example for consist number 60:<br />
CV19=60 DCC DC<br />
Front Engine CV21=255 CV22=255 CV229=133 CV223=133<br />
Middle Engine CV21=128 CV22=5 CV229=0 CV223=0<br />
Rear engine CV21=128 CV22=5 CV229=2 CV223=2<br />
See Consist, a technical discussion.<br />
Page 10 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Bit 4:<br />
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
0=F8 Disabled<br />
1=F8 Enabled<br />
0=F7 Disabled<br />
1=F7 Enabled<br />
0=F6 Disabled<br />
1=F6 Enabled<br />
0=F5 Disabled<br />
1=F5 Enabled<br />
0=F4 Disabled<br />
1=F4 Enabled<br />
0=F3 Disabled<br />
1=F3 Enabled<br />
0=F2 Disabled<br />
1=F2 Enabled<br />
0=F1 Disabled<br />
1=F1 Enabled<br />
Page 11 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV22<br />
Consist Functions Type 1<br />
SYSTEM CVs<br />
Description<br />
Determines Which Functions (F0; F9-F12) are Allowed in the Consist<br />
Values<br />
0-255<br />
Initial Value<br />
255<br />
Related CVs<br />
CV19, CV21, CV223, CV229<br />
Bit 7 Bit 0<br />
nu nu F12 F11 F10 F9 nu F0<br />
The decoder responds to all functions that have a “1” set in this CV<br />
once a consist is configured. A consist is configured by CV19<br />
programmed to a value from 1-127. A value of 0 breaks the consist.<br />
See CV19. This CV is used to configure the engine for a front, middle<br />
or end in the consist.<br />
An example for consist number 60:<br />
CV19=60 DCC DC<br />
Front Engine CV21=255 CV22=255 CV229=133 CV223=133<br />
Middle Engine CV21=128 CV22=5 CV229=0 CV223=0<br />
Rear engine CV21=128 CV22=5 CV229=2 CV223=2<br />
See Consist, a technical discussion.<br />
Page 12 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Bit 4:<br />
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
not used<br />
not used<br />
0=F12 Disabled<br />
1=F12 Enabled<br />
0=F11 Disabled<br />
1=F11 Enabled<br />
0=F10 Disabled<br />
1=F10 Enabled<br />
0=F9 Disabled<br />
1=F9 Enabled<br />
not used<br />
0=F0 Disabled<br />
1=F0 Enabled<br />
Page 13 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SYSTEM CVs<br />
CV29<br />
Configuration Bits<br />
Description<br />
Decoder Configuration Feature Bits<br />
Values<br />
0, 1, 2, 3, 32, 33, 34 or 35<br />
Initial Value<br />
2 (Primary Address)<br />
Related CVs<br />
CV1, CV17, CV18<br />
Bit 7 Bit 0<br />
0 0 EA 0 0 0 1 0<br />
Bit 5:<br />
Bit 1:<br />
Bit 0:<br />
EA (Extended Address Mode Enable)<br />
0 = Decoder Responds to Primary Address CV1<br />
1 = Decoder Responds to Extended Address CV17, CV18<br />
0 = 14 speed step if controller set for 14 bits<br />
1 = 28 speed step if controller set for 28 bits<br />
0 = normal lighting for front and rear lights<br />
1 = reverse lighting for front and rear lights<br />
Value of 32 will cause Bit 5 to become 1<br />
Page 14 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
FUNCTION CVs<br />
CV33<br />
F0(f) Output Function Definition<br />
Description<br />
Selects Which Function(s) F0 Activates<br />
Values<br />
0 to 255<br />
Initial Value<br />
1 (Front Lamp)<br />
Related CVs<br />
CV33—CV46<br />
Bit 7 Bit 0<br />
Blow/C+ Air Couple Bell Horn Whistle RL FL<br />
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Bit 4:<br />
Blow Down/Increase Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Blow Down Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Increased<br />
Air Pump Sound Effects<br />
0 = Not Affected by F0<br />
1 = Air Pump Sound Activated/Deactivated by F0<br />
Coupler Sound Effects<br />
0 = Not Affected by F0<br />
1 = Coupler Sound Activated by F0 if Engine Moving<br />
Uncouple Armed if Engine Stopped<br />
Bell Sound Effects<br />
0 = Not Affected by F0<br />
1 = Bell Activated by F0<br />
Page 15 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
Horn Sound Effects (If Model Has This Effect)<br />
0 = Not Affected by F0<br />
1 = Horn Activated by F0<br />
Whistle Sound Effects<br />
0 = Not Affected by F0<br />
1 = Whistle Activated by F0<br />
Rear Light Visual Effects<br />
0 = Not Affected by F0<br />
1 = Rear Light Visual Effect Activated by F0<br />
Front Light Visual Effects<br />
0 = Not Affected by F0<br />
1 = Front Light Visual Effect Activated by F0<br />
Page 16 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
FUNCTION CVs<br />
CV34<br />
F0(r) Output Function Definition<br />
Description<br />
Selects Which Function(s) F0 Activates<br />
Values<br />
0 to 255<br />
Initial Value<br />
2 (Rear Lamp)<br />
Related CVs<br />
CV33—CV46<br />
Bit 7 Bit 0<br />
Blow/C+ Air Couple Bell Horn Whistle RL FL<br />
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Bit 4:<br />
Blow Down/Increase Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Blow Down Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Increased<br />
Air Pump Sound Effects<br />
0 = Not Affected by F0<br />
1 = Air Pump Sound Activated/Deactivated by F0<br />
Coupler Sound Effects<br />
0 = Not Affected by F0<br />
1 = Coupler Sound Activated by F0 if Engine Moving<br />
Uncouple Armed if Engine Stopped<br />
Bell Sound Effects<br />
0 = Not Affected by F0<br />
1 = Bell Activated by F0<br />
Page 17 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
Horn Sound Effects (If Model Has This Effect)<br />
0 = Not Affected by F0<br />
1 = Horn Activated by F0<br />
Whistle Sound Effects<br />
0 = Not Affected by F0<br />
1 = Whistle Activated by F0<br />
Rear Light Visual Effects<br />
0 = Not Affected by F0<br />
1 = Rear Light Visual Effect Activated by F0<br />
Front Light Visual Effects<br />
0 = Not Affected by F0<br />
1 = Front Light Visual Effect Activated by F0<br />
Page 18 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV35<br />
F1 Output Function Definition<br />
FUNCTION CVs<br />
Description<br />
Selects Which Function(s) F1 Activates<br />
Values<br />
0 to 255<br />
Initial Value<br />
16 (Bell)<br />
Related CVs<br />
CV33—CV46<br />
Bit 7 Bit 0<br />
Blow/C+ Air Couple Bell Horn Whistle RL FL<br />
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Bit 4:<br />
Blow Down/Increase Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Blow Down Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Increased<br />
Air Pump Sound Effects<br />
0 = Not Affected by F0<br />
1 = Air Pump Sound Activated/Deactivated by F0<br />
Coupler Sound Effects<br />
0 = Not Affected by F0<br />
1 = Coupler Sound Activated by F0 if Engine Moving<br />
Uncouple Armed if Engine Stopped<br />
Bell Sound Effects<br />
0 = Not Affected by F0<br />
1 = Bell Activated by F0<br />
Page 19 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
Horn Sound Effects (If Model Has This Effect)<br />
0 = Not Affected by F0<br />
1 = Horn Activated by F0<br />
Whistle Sound Effects<br />
0 = Not Affected by F0<br />
1 = Whistle Activated by F0<br />
Rear Light Visual Effects<br />
0 = Not Affected by F0<br />
1 = Rear Light Visual Effect Activated by F0<br />
Front Light Visual Effects<br />
0 = Not Affected by F0<br />
1 = Front Light Visual Effect Activated by F0<br />
Page 20 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV36<br />
F2 Output Function Definition<br />
FUNCTION CVs<br />
Description<br />
Selects Which Function(s) F2 Activates<br />
Values<br />
0 to 255<br />
Initial Value<br />
4(Whistle)<br />
Related CVs<br />
CV33—CV46<br />
Bit 7 Bit 0<br />
Blow/C+ Air Couple Bell Horn Whistle RL FL<br />
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Bit 4:<br />
Blow Down/Increase Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Blow Down Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Increased<br />
Air Pump Sound Effects<br />
0 = Not Affected by F0<br />
1 = Air Pump Sound Activated/Deactivated by F0<br />
Coupler Sound Effects<br />
0 = Not Affected by F0<br />
1 = Coupler Sound Activated by F0 if Engine Moving<br />
Uncouple Armed if Engine Stopped<br />
Bell Sound Effects<br />
0 = Not Affected by F0<br />
1 = Bell Activated by F0<br />
Page 21 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
Horn Sound Effects (If Model Has This Effect)<br />
0 = Not Affected by F0<br />
1 = Horn Activated by F0<br />
Whistle Sound Effects<br />
0 = Not Affected by F0<br />
1 = Whistle Activated by F0<br />
Rear Light Visual Effects<br />
0 = Not Affected by F0<br />
1 = Rear Light Visual Effect Activated by F0<br />
Front Light Visual Effects<br />
0 = Not Affected by F0<br />
1 = Front Light Visual Effect Activated by F0<br />
Page 22 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV37<br />
F3 Output Function Definition<br />
FUNCTION CVs<br />
Description<br />
Selects Which Function(s) F3 Activates<br />
Values<br />
0 to 255<br />
Initial Value<br />
32 (Couple/Uncouple)<br />
Related CVs<br />
CV33—CV46<br />
Bit 7 Bit 0<br />
Blow/C+ Air Couple Bell Horn Whistle RL FL<br />
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Bit 4:<br />
Blow Down/Increase Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Blow Down Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Increased<br />
Air Pump Sound Effects<br />
0 = Not Affected by F0<br />
1 = Air Pump Sound Activated/Deactivated by F0<br />
Coupler Sound Effects<br />
0 = Not Affected by F0<br />
1 = Coupler Sound Activated by F0 if Engine Moving<br />
Uncouple Armed if Engine Stopped<br />
Bell Sound Effects<br />
0 = Not Affected by F0<br />
1 = Bell Activated by F0<br />
Page 23 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
Horn Sound Effects (If Model Has This Effect)<br />
0 = Not Affected by F0<br />
1 = Horn Activated by F0<br />
Whistle Sound Effects<br />
0 = Not Affected by F0<br />
1 = Whistle Activated by F0<br />
Rear Light Visual Effects<br />
0 = Not Affected by F0<br />
1 = Rear Light Visual Effect Activated by F0<br />
Front Light Visual Effects<br />
0 = Not Affected by F0<br />
1 = Front Light Visual Effect Activated by F0<br />
Page 24 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV38<br />
F4 Output Function Definition<br />
FUNCTION CVs<br />
Description<br />
Selects Which Function(s) F4 Activates<br />
Values<br />
0 to 255<br />
Initial Value<br />
8 (Air Pump)<br />
Related CVs<br />
CV33—CV46<br />
Bit 7 Bit 0<br />
Volume L1 Water/C- Blow/C+ Air Couple Bell Horn<br />
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Volume Audio Effects<br />
0 = Not Affected by F4<br />
1 = Volume Increases or Decreases on a Double Press<br />
Volume Mutes on a Single Press<br />
Light One Visual Effects<br />
0 = Not Affected by F4<br />
1 = Visual Light One Activated<br />
Water Fill/Decrease Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Water Fill Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Decreased<br />
Page 25 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 4:<br />
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
Blow Down/Increase Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Blow Down Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Increased<br />
Air Pump Sound Effects<br />
0 = Not Affected by F0<br />
1 = Air Pump Sound Activated/Deactivated by F0<br />
Coupler Sound Effects<br />
0 = Not Affected by F0<br />
1 = Coupler Sound Activated by F0 if Engine Moving<br />
Uncouple Armed if Engine Stopped<br />
Bell Sound Effects<br />
0 = Not Affected by F4<br />
1 = Bell Activated by F4<br />
Horn Sound Effects (If Model Has This Effect)<br />
0 = Not Affected by F4<br />
1 = Horn Activated by F4<br />
Page 26 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV39<br />
F5 Output Function Definition<br />
FUNCTION CVs<br />
Description<br />
Selects Which Function(s) F5 Activates<br />
Values<br />
0 to 255<br />
Initial Value<br />
16 (Blow Down/Increase Chuff Magnitude)<br />
Related CVs<br />
CV33—CV46; CV196—CV205<br />
Bit 7 Bit 0<br />
Volume L1 Water/C- Blow/C+ Air Couple Bell Horn<br />
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Volume Audio Effects<br />
0 = Not Affected by F4<br />
1 = Volume Increases or Decreases on a Double Press<br />
Volume Mutes on a Single Press<br />
Light One Visual Effects<br />
0 = Not Affected by F4<br />
1 = Visual Light One Activated<br />
Water Fill/Decrease Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Water Fill Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Decreased<br />
Page 27 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 4:<br />
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
Blow Down/Increase Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Blow Down Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Increased<br />
Air Pump Sound Effects<br />
0 = Not Affected by F0<br />
1 = Air Pump Sound Activated/Deactivated by F0<br />
Coupler Sound Effects<br />
0 = Not Affected by F0<br />
1 = Coupler Sound Activated by F0 if Engine Moving<br />
Uncouple Armed if Engine Stopped<br />
Bell Sound Effects<br />
0 = Not Affected by F4<br />
1 = Bell Activated by F4<br />
Horn Sound Effects (If Model Has This Effect)<br />
0 = Not Affected by F4<br />
1 = Horn Activated by F4<br />
Page 28 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV40<br />
F6 Output Function Definition<br />
FUNCTION CVs<br />
Description<br />
Selects Which Function(s) F6 Activates<br />
Values<br />
0 to 255<br />
Initial Value<br />
32 (Water/Increase Chuff Magnitude)<br />
Related CVs<br />
CV33—CV46; CV196—CV205<br />
Bit 7 Bit 0<br />
Volume L1 Water/C- Blow/C+ Air Couple Bell Horn<br />
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Volume Audio Effects<br />
0 = Not Affected by F4<br />
1 = Volume Increases or Decreases on a Double Press<br />
Volume Mutes on a Single Press<br />
Light One Visual Effects<br />
0 = Not Affected by F4<br />
1 = Visual Light One Activated<br />
Water Fill/Decrease Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Water Fill Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Decreased<br />
Page 29 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 4:<br />
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
Blow Down/Increase Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Blow Down Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Increased<br />
Air Pump Sound Effects<br />
0 = Not Affected by F0<br />
1 = Air Pump Sound Activated/Deactivated by F0<br />
Coupler Sound Effects<br />
0 = Not Affected by F0<br />
1 = Coupler Sound Activated by F0 if Engine Moving<br />
Uncouple Armed if Engine Stopped<br />
Bell Sound Effects<br />
0 = Not Affected by F4<br />
1 = Bell Activated by F4<br />
Horn Sound Effects (If Model Has This Effect)<br />
0 = Not Affected by F4<br />
1 = Horn Activated by F4<br />
Page 30 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV41<br />
F7 Output Function Definition<br />
FUNCTION CVs<br />
Description<br />
Selects Which Function(s) F7 Activates<br />
Values<br />
0 to 255<br />
Initial Value<br />
64 (L1 Visual Effects)<br />
Related CVs<br />
CV33—CV46; CV160—CV164<br />
Bit 7 Bit 0<br />
Volume L1 Water/C- Blow/C+ Air Couple Bell Horn<br />
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Volume Audio Effects<br />
0 = Not Affected by F4<br />
1 = Volume Increases or Decreases on a Double Press<br />
Volume Mutes on a Single Press<br />
Light One Visual Effects<br />
0 = Not Affected by F4<br />
1 = Visual Light One Activated<br />
Water Fill/Decrease Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Water Fill Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Decreased<br />
Page 31 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 4:<br />
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
Blow Down/Increase Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Blow Down Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Increased<br />
Air Pump Sound Effects<br />
0 = Not Affected by F0<br />
1 = Air Pump Sound Activated/Deactivated by F0<br />
Coupler Sound Effects<br />
0 = Not Affected by F0<br />
1 = Coupler Sound Activated by F0 if Engine Moving<br />
Uncouple Armed if Engine Stopped<br />
Bell Sound Effects<br />
0 = Not Affected by F4<br />
1 = Bell Activated by F4<br />
Horn Sound Effects (If Model Has This Effect)<br />
0 = Not Affected by F4<br />
1 = Horn Activated by F4<br />
Page 32 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV42<br />
F8 Output Function Definition<br />
FUNCTION CVs<br />
Description<br />
Selects Which Function(s) F8 Activates<br />
Values<br />
0 to 255<br />
Initial Value<br />
128 (Volume Audio Effect)<br />
Related CVs<br />
CV33—CV46<br />
Bit 7 Bit 0<br />
Volume L1 Water/C- Blow/C+ Air Couple Bell Horn<br />
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Volume Audio Effects<br />
0 = Not Affected by F4<br />
1 = Volume Increases or Decreases on a Double Press<br />
Volume Mutes on a Single Press<br />
Light One Visual Effects<br />
0 = Not Affected by F4<br />
1 = Visual Light One Activated<br />
Water Fill/Decrease Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Water Fill Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Decreased<br />
Page 33 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 4:<br />
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
Blow Down/Increase Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Blow Down Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Increased<br />
Air Pump Sound Effects<br />
0 = Not Affected by F0<br />
1 = Air Pump Sound Activated/Deactivated by F0<br />
Coupler Sound Effects<br />
0 = Not Affected by F0<br />
1 = Coupler Sound Activated by F0 if Engine Moving<br />
Uncouple Armed if Engine Stopped<br />
Bell Sound Effects<br />
0 = Not Affected by F4<br />
1 = Bell Activated by F4<br />
Horn Sound Effects (If Model Has This Effect)<br />
0 = Not Affected by F4<br />
1 = Horn Activated by F4<br />
Page 34 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV43<br />
F9 Output Function Definition<br />
FUNCTION CVs<br />
Description<br />
Selects Which Function(s) F9 Activates<br />
Values<br />
0 to 255<br />
Initial Value<br />
16 (Shutdown and Startup Audio Effect)<br />
Related CVs<br />
CV33—CV46<br />
Bit 7 Bit 0<br />
Brakes Injector Coal Sht/Str L1 Water/C- Blow/C+ Air<br />
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Brakes Effects<br />
0 = Not Affected by F9<br />
1 = If Engine at Throttle Stop Zero:<br />
Set Air Brake Effect<br />
If Engine not at Throttle Stop Zero:<br />
Release Air Brake Effect Activated<br />
Injector Effect<br />
0 = Not Affected by F9<br />
1 = Water Injector Effect Activated<br />
Shovel Coal<br />
0 = Not Affected by F9<br />
1 = Coal Shovel/Auger Effect Activated<br />
Page 35 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 4:<br />
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
Shut Down or Start Up <strong>Steam</strong> Engine Sound Effects<br />
0 = Not Affected by F9<br />
1 = If at Idle, Play Shutdown Sound Effect<br />
If not at Idle, ignored.<br />
1= If Silent (Shutdown) than Play Startup Sound Effect<br />
Light One Visual Effects<br />
0 = Not Affected by F9<br />
1 = Visual Light One Activated<br />
Water Fill/Decrease Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Water Fill Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Decreased<br />
Blow Down/Increase Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Blow Down Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Increased<br />
Air Pump Sound Effects<br />
0 = Not Affected by F0<br />
1 = Air Pump Sound Activated/Deactivated by F0<br />
Page 36 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
FUNCTION CVs<br />
CV44<br />
F10 Output Function Definition<br />
Description<br />
Selects Which Function(s) F10 Activates<br />
Values<br />
0 to 255<br />
Initial Value<br />
32 (Shovel/Auger Coal Audio Effect)<br />
Related CVs<br />
CV33—CV46<br />
Bit 7 Bit 0<br />
Brakes Injector Coal Sht/Str L1 Water/C- Blow/C+ Air<br />
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Brakes Effects<br />
0 = Not Affected by F9<br />
1 = If Engine at Throttle Stop Zero:<br />
Set Air Brake Effect<br />
If Engine not at Throttle Stop Zero:<br />
Release Air Brake Effect Activated<br />
Injector Effect<br />
0 = Not Affected by F9<br />
1 = Water Injector Effect Activated<br />
Shovel Coal<br />
0 = Not Affected by F9<br />
1 = Coal Shovel/Auger Effect Activated<br />
Page 37 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 4:<br />
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
Shut Down or Start Up <strong>Steam</strong> Engine Sound Effects<br />
0 = Not Affected by F9<br />
1 = If at Idle, Play Shutdown Sound Effect<br />
If not at Idle, ignored.<br />
1= If Silent (Shutdown) than Play Startup Sound Effect<br />
Light One Visual Effects<br />
0 = Not Affected by F9<br />
1 = Visual Light One Activated<br />
Water Fill/Decrease Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Water Fill Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Decreased<br />
Blow Down/Increase Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Blow Down Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Increased<br />
Air Pump Sound Effects<br />
0 = Not Affected by F0<br />
1 = Air Pump Sound Activated/Deactivated by F0<br />
Page 38 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
FUNCTION CVs<br />
CV45<br />
F11 Output Function Definition<br />
Description<br />
Selects Which Function(s) F11 Activates<br />
Values<br />
0 to 255<br />
Initial Value<br />
64 (Water Injector Audio Effect)<br />
Related CVs<br />
CV33—CV46<br />
Bit 7 Bit 0<br />
Brakes Injector Coal Sht/Str L1 Water/C- Blow/C+ Air<br />
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Brakes Effects<br />
0 = Not Affected by F9<br />
1 = If Engine at Throttle Stop Zero:<br />
Set Air Brake Effect<br />
If Engine not at Throttle Stop Zero:<br />
Release Air Brake Effect Activated<br />
Injector Effect<br />
0 = Not Affected by F9<br />
1 = Water Injector Effect Activated<br />
Shovel Coal<br />
0 = Not Affected by F9<br />
1 = Coal Shovel/Auger Effect Activated<br />
Page 39 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 4:<br />
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
Shut Down or Start Up <strong>Steam</strong> Engine Sound Effects<br />
0 = Not Affected by F9<br />
1 = If at Idle, Play Shutdown Sound Effect<br />
If not at Idle, ignored.<br />
1= If Silent (Shutdown) than Play Startup Sound Effect<br />
Light One Visual Effects<br />
0 = Not Affected by F9<br />
1 = Visual Light One Activated<br />
Water Fill/Decrease Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Water Fill Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Decreased<br />
Blow Down/Increase Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Blow Down Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Increased<br />
Air Pump Sound Effects<br />
0 = Not Affected by F0<br />
1 = Air Pump Sound Activated/Deactivated by F0<br />
Page 40 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
FUNCTION CVs<br />
CV46<br />
F12 Output Function Definition<br />
Description<br />
Selects Which Function(s) F12 Activates<br />
Values<br />
0 to 255<br />
Initial Value<br />
128 (Brake Audio Effects)<br />
Related CVs<br />
CV33—CV46<br />
Bit 7 Bit 0<br />
Brakes Injector Coal Sht/Str L1 Water/C- Blow/C+ Air<br />
Bit 7:<br />
Bit 6:<br />
Bit 5:<br />
Brakes Effects<br />
0 = Not Affected by F9<br />
1 = If Engine at Throttle Stop Zero:<br />
Set Air Brake Effect<br />
If Engine not at Throttle Stop Zero:<br />
Release Air Brake Effect Activated<br />
Injector Effect<br />
0 = Not Affected by F9<br />
1 = Water Injector Effect Activated<br />
Shovel Coal<br />
0 = Not Affected by F9<br />
1 = Coal Shovel/Auger Effect Activated<br />
Page 41 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Bit 4:<br />
Bit 3:<br />
Bit 2:<br />
Bit 1:<br />
Bit 0:<br />
Shut Down or Start Up <strong>Steam</strong> Engine Sound Effects<br />
0 = Not Affected by F9<br />
1 = If at Idle, Play Shutdown Sound Effect<br />
If not at Idle, ignored.<br />
1= If Silent (Shutdown) than Play Startup Sound Effect<br />
Light One Visual Effects<br />
0 = Not Affected by F9<br />
1 = Visual Light One Activated<br />
Water Fill/Decrease Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Water Fill Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Decreased<br />
Blow Down/Increase Chuff Magnitude Sound Effects<br />
0 = Not Affected by F0<br />
1 = Blow Down Sound Activated by F0 if Engine Stopped<br />
1 = Chuff Magnitude Increased<br />
Air Pump Sound Effects<br />
0 = Not Affected by F0<br />
1 = Air Pump Sound Activated/Deactivated by F0<br />
Page 42 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV130<br />
Master Volume Sound Increment<br />
Description<br />
This Value is the Increment/Decrement Amount for Master Volume<br />
Values<br />
0 to 16<br />
Initial Value<br />
2<br />
Related CVs<br />
CV42, CV133<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 1 0<br />
The decoder’s analog potentiometer (volume control) increases or<br />
decreases the volume of the sound. The change between the 16<br />
available steps may be set from 0 to 16. Every press of the volume<br />
toggle switch will result in a volume change incrementing or<br />
decrementing by this value.<br />
Page 43 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV131<br />
Analog Sound Unit Startup (Turn-On) Voltage<br />
Description<br />
This Value Sets the Decoders Sound Turn-On Voltage<br />
Values<br />
0 to 255<br />
Initial Value<br />
56<br />
Related CVs<br />
CV132, CV133<br />
Bit 7 Bit 0<br />
0 0 1 1 1 0 0 0<br />
The sound unit has a minimum power requirement necessary to play<br />
all sound effects. Many factors contribute to what the necessary<br />
voltage is such as the power source, the startup volume (CV133) and<br />
system loading. Lowering this value will instruct the sound unit to<br />
start the audio effects at a lower voltage. Note: Care should be<br />
taken with this value. Lowering this value too low will result in<br />
the unit not being able to function at all. If this occurs, set this<br />
value to a larger number or the initial value and reprogram the<br />
value in service mode.<br />
Page 44 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV132<br />
Analog Sound Unit Shutdown (Turn-Off) Voltage<br />
Description<br />
This Value Sets the Decoders Sound Turn-Off Voltage<br />
Values<br />
0 to 255<br />
Initial Value<br />
54<br />
Related CVs<br />
CV131, CV133<br />
Bit 7 Bit 0<br />
0 0 1 1 0 1 1 0<br />
The sound unit is instructed to play the shutdown effect and turn off<br />
all effects at this value. The shutdown effect only plays from the idle<br />
condition. Many factors contribute to what this actual voltage is such<br />
as the power source, system volume, individual volumes (CV133,<br />
CV135—CV161) and system loading. Lowering this value will<br />
instruct the sound unit to play the shutdown effect at a lower voltage.<br />
Note: Care should be taken with this value. Lowering this value<br />
too low will result in the unit not being able to play the shutdown<br />
effect and terminate all effects properly. The sound unit could<br />
abruptly shut off. If this occurs, set this value to a larger number or<br />
the initial value.<br />
Page 45 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV133<br />
Sound Unit Master Volume<br />
SOUND CVs<br />
Description<br />
This Value Sets the Power Up Master Sound Effects Volume<br />
Values<br />
0 to 16<br />
Initial Value<br />
15<br />
Related CVs<br />
CV130<br />
Bit 7 Bit 0<br />
0 0 0 0 1 1 1 1<br />
The decoder’s analog potentiometer (volume control) increases or<br />
decreases the volume of the sound. The change between the 16<br />
available steps may be set from 0 to 16. Every press of the volume<br />
toggle switch will result in a volume change incrementing or<br />
decrementing by this value. This value is the decoder’s power up<br />
value. A higher value increases the volume while a lower value<br />
decreases the volume.<br />
Page 46 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV135<br />
Whistle Volume<br />
Description<br />
This Value Controls the Whistle Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV36, CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s whistle sound effect volume is variable from 0 to 255%.<br />
A higher value increases the volume while a lower value decreases<br />
the volume.<br />
Page 47 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV136<br />
Bell Volume<br />
Description<br />
This Value Controls the Bell Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV35, CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s bell sound effect volume is variable from 0 to 255%. A<br />
higher value increases the volume while a lower value decreases the<br />
volume.<br />
Page 48 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV137<br />
<strong>Steam</strong> Volume<br />
Description<br />
This Value Controls the Startup, Three Backgrounds and Shutdown<br />
Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s steam engine sound effects volume is variable from 0<br />
to 255%. A higher value increases the volume while a lower value<br />
decreases the volume. This value controls a group of sounds: steam<br />
startup, three unique steam backgrounds and steam shutdown sound<br />
effects.<br />
Page 49 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV138<br />
Horn Volume<br />
Description<br />
This Value Controls the Horn Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s horn sound effect volume is variable from 0 to 255%.<br />
A higher value increases the volume while a lower value decreases<br />
the volume. Note: This sound effect is not used in most engines.<br />
Page 50 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV140<br />
Couple Volume<br />
Description<br />
This Value Controls the Couple Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV37, CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s couple sound effect volume is variable from 0 to 255%.<br />
The couple sound effect only plays if the engine is moving and the<br />
function is pressed. This sound effect may be activated with a DCC<br />
Function or AUX with a DCMaster. A higher value increases the<br />
volume while a lower value decreases the volume.<br />
Page 51 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV141<br />
Uncouple Volume<br />
Description<br />
This Value Controls the Uncouple Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV37, CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s uncouple sound effect volume is variable from 0 to<br />
255%. The uncouple sound effect plays once after it is armed. The<br />
process of arming is: press the function with engine stopped, upon<br />
engine moving the uncouple sound effect plays. This sound effect<br />
may be activated with a DCC Function or AUX with a DCMaster. A<br />
higher value increases the volume while a lower value decreases the<br />
volume.<br />
Page 52 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV143<br />
Air Pump Volume<br />
Description<br />
This Value Controls the Air Pump Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV38, CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s air pump sound effect volume is variable from 0 to<br />
255%. The air pump sound effect plays if the engine is stopped or<br />
moving. This sound effect may be activated with a DCC Function or<br />
AUX with a DCMaster and is also a random sound effect when<br />
stopped. A higher value increases the volume while a lower value<br />
decreases the volume.<br />
Page 53 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV144<br />
Blow Down Volume<br />
SOUND CVs<br />
Description<br />
This Value Controls the Blow Down Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV45, CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s blow down sound effect volume is variable from 0 to<br />
255%. This sound effect may be activated with a DCC Function only<br />
if the engine is stopped and is also a random sound effect when<br />
stopped. A higher value increases the volume while a lower value<br />
decreases the volume.<br />
Page 54 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV145<br />
<strong>Steam</strong> Cock Volume<br />
SOUND CVs<br />
Description<br />
This Value Controls the <strong>Steam</strong> Cock Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV45, CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s steam cock sound effects volume is variable from 0 to<br />
255%. This sound effect is a random sound effect that only plays<br />
when stopped. A higher value increases the volume while a lower<br />
value decreases the volume.<br />
Page 55 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV146<br />
Brake Set Volume<br />
Description<br />
This Value Controls the Brake Set Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV46, CV133, CV191, CV209, CV227<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s brake set sound effect volume is variable from 0 to<br />
255%. The brake set sound effect only plays if the track voltage falls<br />
below the analog brake set voltage (CV191) for analog mode or<br />
pressing the Function for DCC. In DCC mode the brake set effect<br />
plays when the current speed step matches or is lower than the DCC<br />
Brake Set Throttle Stop (CV209). A higher value increases the<br />
volume while a lower value decreases the volume.<br />
Page 56 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV147<br />
Brake Release Volume<br />
SOUND CVs<br />
Description<br />
This Value Controls the Brake Release Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV46, CV133, CV192, CV210, CV227<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s brake release sound effect volume is variable from 0 to<br />
255%. The brake release sound effect only plays if the track voltage is<br />
increased above the analog brake set voltage (CV192) for analog<br />
mode or pressing the Function for DCC. In DCC mode the brake<br />
release effect plays when the current speed step matches or is higher<br />
than the DCC Brake Release Throttle Stop (CV210). A higher value<br />
increases the volume while a lower value decreases the volume.<br />
Page 57 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV148<br />
Pop Off Valve Volume<br />
SOUND CVs<br />
Description<br />
This Value Controls the Pop Off Valve Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s pop off valve sound effect volume is variable from 0 to<br />
255%. The pop off valve sound effect is a random sound that only<br />
plays when the engine is stopped. A higher value increases the<br />
volume while a lower value decreases the volume.<br />
Page 58 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV149<br />
Blower Volume<br />
Description<br />
This Value Controls the Blower Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV44, CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s blower sound effect volume is variable from 0 to 255%.<br />
This sound effect is a random sound effect when the engine is<br />
stopped. A higher value increases the volume while a lower value<br />
decreases the volume.<br />
Page 59 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV150<br />
Dynamo Volume<br />
Description<br />
This Value Controls the Dynamo Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV38, CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s dynamo sound effect volume is variable from 0 to<br />
255%. The dynamo on sound effect plays for a short period before<br />
the headlights are turned on. The sound effect then fades into the<br />
background. The dynamo off sound effect plays for a short period<br />
after the lights are turned off. The sound effect then fades into the<br />
background. A higher value increases the volume while a lower<br />
value decreases the volume.<br />
Page 60 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV151<br />
Brakes Squeal Volume<br />
SOUND CVs<br />
Description<br />
This Value Controls the Brakes Squeal Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV46, CV133, CV227<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s brake squeal sound effect volume is variable from 0 to<br />
255%. In analog and DCC mode, the brakes squeal sound effect plays<br />
if the change in track voltage (analog mode [CV184]) or the speed<br />
steps (DCC Mode [CV185]) exceeds the preset threshold. The brakes<br />
squeal sound effect plays if the DCC Function is enabled (CV227). A<br />
higher value increases the volume while a lower value decreases the<br />
volume.<br />
Page 61 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV152<br />
Shovel/Auger Coal Volume<br />
SOUND CVs<br />
Description<br />
This Value Controls the Shovel Coal Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s shovel/auger coal sound effect volume is variable from<br />
0 to 255%. The shovel/auger coal sound effect plays by pressing the<br />
Function for DCC. The shovel/auger coal sound effect is a random<br />
sound that only plays when the engine is stopped. This sound effect<br />
is also a random sound that plays when the engine is stopped. A<br />
higher value increases the volume while a lower value decreases the<br />
volume.<br />
Page 62 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV153<br />
Water Fill Volume<br />
Description<br />
This Value Controls the Water Fill Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s water fill sound effect volume is variable from 0 to<br />
255%. The water fill sound effect plays by pressing the Function for<br />
DCC. The water fill sound effect only plays when the engine is<br />
stopped. A higher value increases the volume while a lower value<br />
decreases the volume.<br />
Page 63 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV154<br />
Injector Volume<br />
Description<br />
This Value Controls the Water Injector Sound Effects Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV133<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s water injector sound effect volume is variable from 0<br />
to 255%. The water injector sound effect plays by pressing the<br />
Function for DCC. This sound effect is also a random sound that<br />
plays when the engine is stopped. A higher value increases the<br />
volume while a lower value decreases the volume.<br />
Page 64 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SOUND CVs<br />
CV155<br />
Chuff/<strong>Steam</strong> Cock Chuffs Volume<br />
Description<br />
This Value Controls the Chuff and <strong>Steam</strong> Cock Chuffs Sound Effects<br />
Volume<br />
Values<br />
0 to 255<br />
Initial Value<br />
100<br />
Related CVs<br />
CV133, CV196<br />
Bit 7 Bit 0<br />
0 1 1 0 0 1 0 0<br />
The decoder’s chuff and steam cock chuffs sound effect volume is<br />
variable from 0 to 255%. A higher value increases the volume while a<br />
lower value decreases the volume.<br />
Page 65 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Lighting CVs<br />
CV159<br />
System Lighting<br />
Description<br />
This Value Controls System Lighting Functions<br />
Values<br />
0-255<br />
Initial Value<br />
0<br />
Related CVs<br />
CV209, CV210, CV227; CV191, CV192<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 0<br />
The decoder’s visual lighting effects for the front and rear light are<br />
configured here. Rule 17 lighting may be enabled or disabled by<br />
writing a “0” or a “1” to Value. In addition, separate bits allow for<br />
independent control of Rule 17 for DCC or DC.<br />
Rule 17 Lighting<br />
Rule 17 Lighting says “Headlights shall be dimmed when standing<br />
at stations or waiting on side tracks for an oncoming train”. When<br />
rule 17 lighting is enabled, the headlight will be noticeable dimmed<br />
at appropriately times.<br />
Page 66 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
DCC Rule 17 Lighting<br />
For DC operators, the lights will dim per rule 17 when the brake set<br />
sound effect plays (CV209). The lights will return to normal<br />
brightness when the brake release sound plays (CV210). In addition,<br />
CV227 allows for disabling the brake set and brake release. Disabling<br />
these automatic effects does disable rule 17 lighting. Only CV159 can<br />
disable rule 17 lighting.<br />
DC Rule 17 Lighting<br />
For DC operators, the lights will dim per rule 17 when the brake set<br />
sound effect plays (CV191). The lights will return to normal<br />
brightness when the brake release sound plays (CV192).<br />
Bit7:<br />
Bit6:<br />
Bit5:<br />
Bit4:<br />
Bit3:<br />
Bit2:<br />
Bit1:<br />
Bit0:<br />
Not used<br />
Not used<br />
Not used<br />
0=DC Rule 17 Lighting Enabled<br />
1=DC Rule 17 Lighting Disabled<br />
Not used<br />
Not used<br />
Not used<br />
0=DCC Rule 17 Lighting Enabled<br />
1= DCC Rule 17 Lighting Disabled<br />
Page 67 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV160<br />
L1 Light Definition<br />
Lighting CVs<br />
Description<br />
This Value Sets the Function Type and Definition for Output L1<br />
Values<br />
0 to 3<br />
Initial Value<br />
1<br />
Related CVs<br />
CV161, CV162, CV163, CV164, CV210, CV215<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 1<br />
The decoder’s visual lighting effects for L1 output may be one of<br />
three types. Each defined type then uses 2 to 4 of the next 4 CV’s<br />
allowing uses definition of all the parameters. CV210 must be<br />
configured to enable L1 for analog modes. CV215 must be configured<br />
to enable L1 for DCC modes. CV210 allows for L1 activating by the<br />
Whistle for ditch lights. The ditch lights may be type 1, 2 or 3.<br />
Type 0:<br />
Output is disabled.<br />
Page 68 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Type 1:<br />
Duty Cycle Strobe. CV161 defines the on time and CV162<br />
defines the off time. Time is measured in 1/32 seconds<br />
per count.<br />
CV161<br />
Example:<br />
CV162<br />
CV160=1<br />
CV161=32 for 1 second on<br />
CV162=64 for 2 seconds off<br />
Type 2:<br />
Double Pulsed Duty Cycle Strobe. CV161 defines the on<br />
time one; CV162 defines off time one; CV163 defines on<br />
time two; CV164 defines off time two. Time is measured<br />
in 1/32 seconds per count.<br />
CV161 CV162 CV163 CV164<br />
Example:<br />
CV160=2<br />
CV161=8 for .25 seconds for on time one<br />
CV162=16 for .5 seconds for off time one<br />
CV163=16 for .5 seconds for on time two<br />
CV164=64 for 2 seconds for off time two<br />
Page 69 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Type 3:<br />
Ramped Duty Cycle. CV161 defines the start of the on<br />
time within the period; CV162 defines the ramp up time;<br />
CV163 defines the end of the on time within the period;<br />
CV164 defines the ramp down time. The period is 127<br />
counts. CV161 < CV163 and both should be less than 128.<br />
CV162 and CV164 can be any range from 0 to 255.<br />
0 127<br />
On Time<br />
Ramp Up<br />
Light On<br />
CV161<br />
Ramp Down<br />
CV163<br />
The time between 0 and CV161 represents the total time<br />
the light is turned on over one period. The actual period<br />
time (0 to 127) is 11.6ms. CV162 is a ramp up timer<br />
determining how many periods elapse before the On<br />
Time is increased by one. Once CV161 increases to CV163<br />
value, the ramp down begins. CV164 is a ramp down<br />
timer determining how many periods elapse before the<br />
On Time is decreases by one. Once CV163 decreases to<br />
CV161, the ramp up cycle repeats, etc.<br />
Soft Strobe Example:<br />
CV160=3<br />
CV161=10<br />
CV162=100<br />
CV163=127<br />
CV164=100<br />
Ditch Light Example: CV160=3<br />
CV161=0<br />
CV162=10<br />
CV163=180<br />
CV164=10<br />
Page 70 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Lighting CVs<br />
CV161<br />
L1 Parameter One<br />
Description<br />
This Value is a Light Parameter, Dependant on CV160<br />
Values<br />
Dependant on Type<br />
Initial Value<br />
10<br />
Related CVs<br />
CV160, CV162, CV163, CV164<br />
Bit 7 Bit 0<br />
0 0 0 0 1 0 1 0<br />
Type 0: Not Used<br />
Type1: Sets the On Time; Valid Values 0-255<br />
Type2: Sets On Time One; Valid Values 0-255<br />
Type3: Sets the Start Point for Power On; Valid Values 0-255<br />
CV161
Lighting CVs<br />
CV162<br />
L1 Parameter Two<br />
Description<br />
This Value is a Light Parameter, Dependant on CV160<br />
Values<br />
Dependant on Type<br />
Initial Value<br />
10<br />
Related CVs<br />
CV160, CV161, CV163, CV164<br />
Bit 7 Bit 0<br />
0 0 0 0 1 0 1 0<br />
Type 0: Not Used<br />
Type1: Sets the Off Time; Valid Values 0-255<br />
Type2: Sets Off Time One; Valid Values 0-255<br />
Type3: Sets the Ramp Up Time; Valid Values 0-255<br />
Time measured in 11.6ms per count<br />
Page 72 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV163<br />
L1 Parameter Three<br />
Lighting CVs<br />
Description<br />
This Value is a Light Parameter, Dependant on CV160<br />
Values<br />
Dependant on Type<br />
Initial Value<br />
180<br />
Related CVs<br />
CV160, CV161, CV162, CV164<br />
Bit 7 Bit 0<br />
1 0 1 1 0 1 0 0<br />
Type 0: Not Used<br />
Type1: Not Used<br />
Type2: Sets On Time Two; Valid Values 0-255<br />
Type3: Sets the End Point for Power On; Valid Values 0-255<br />
CV163>CV161<br />
Page 73 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Lighting CVs<br />
CV164<br />
L1 Parameter Four<br />
Description<br />
This Value is a Light Parameter, Dependant on CV160<br />
Values<br />
Dependant on Type<br />
Initial Value<br />
20<br />
Related CVs<br />
CV160, CV161, CV162, CV163<br />
Bit 7 Bit 0<br />
0 0 0 1 0 1 0 0<br />
Type 0: Not Used<br />
Type1: Not Used<br />
Type2: Sets Off Time Two; Valid Values 0-255<br />
Type3: Sets the Ramp Down Time; Valid Values 0-255<br />
Time measured in 11.6ms per count<br />
Page 74 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV180<br />
Bell Ring Interval<br />
Description<br />
This Value Controls the Time Interval Between Bell Strikes<br />
Values<br />
0-120<br />
Initial Value<br />
Varies With Each Bell Sound Effect<br />
Related CVs<br />
CV35<br />
Bit 7 Bit 0<br />
D7 D6 D5 D4 D3 D2 D1 D0<br />
The decoder’s bell ring interval allows the user to customize the time<br />
duration between bell strikes. Increasing this value will increase the<br />
time between bell strikes. This value is updated in operations mode.<br />
Turn on the bell and change this value and hear the bell ring interval<br />
change.<br />
Page 75 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV181<br />
Whistle Fade In Control<br />
SETUP CVs<br />
Description<br />
This Value Controls the Fade-In of the Whistle<br />
Values<br />
0-255<br />
Initial Value<br />
Varies<br />
Related CVs<br />
CV182, CV183<br />
Bit 7 Bit 0<br />
D7 D6 D5 D4 D3 D2 D1 D0<br />
The decoder’s background effects volumes are decreased when a<br />
whistle effect starts to play. This value controls the rate of which the<br />
background fades out while the whistle fades in.<br />
Page 76 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV182<br />
Whistle Fade Out Control<br />
SETUP CVs<br />
Description<br />
This Value Controls the Fade-Out of the Whistle<br />
Values<br />
0-255<br />
Initial Value<br />
Varies<br />
Related CVs<br />
CV181, CV183<br />
Bit 7 Bit 0<br />
D7 D6 D5 D4 D3 D2 D1 D0<br />
The decoder’s background effects volumes are increased while a<br />
whistle effect begins termination. This value controls the rate of<br />
which the background fades in while the whistle fades out.<br />
Page 77 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV183<br />
Whistle Fade In Level<br />
SETUP CVs<br />
Description<br />
This Value Controls the Fade-In of the Whistle<br />
Values<br />
0-255<br />
Initial Value<br />
Varies<br />
Related CVs<br />
CV181, CV182<br />
Bit 7 Bit 0<br />
D7 D6 D5 D4 D3 D2 D1 D0<br />
The decoder’s background effects volumes decrease when a whistle<br />
effect starts fading in. This value controls the background fade level<br />
for the whistle fade in.<br />
Page 78 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV184<br />
Analog Brake Control<br />
SETUP CVs<br />
Description<br />
This Value Controls Analog Brake Effect Activation<br />
Values<br />
0-255<br />
Initial Value<br />
64<br />
Related CVs<br />
Bit 7 Bit 0<br />
0 1 0 0 0 0 0 0<br />
The decoder’s brake squeal effect plays when a track voltage<br />
threshold is met. The threshold is met when the track voltage<br />
decreases fast enough to meet this threshold (CV184). Increasing this<br />
value decreases the brake sensitivity.<br />
Page 79 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV185<br />
DCC Brake Control<br />
SETUP CVs<br />
Description<br />
This Value Controls DCC Brake Effect Activation<br />
Values<br />
0-255<br />
Initial Value<br />
20<br />
Related CVs<br />
CV46, CV186, CV227<br />
Bit 7 Bit 0<br />
0 0 0 1 0 1 0 0<br />
The decoder’s brake squeal effect plays when a speed step threshold<br />
is met. The threshold is met when the speed step decreases fast<br />
enough to meet this threshold (CV185). Increasing this value<br />
decreases the brake sensitivity. Clearing bit1 of CV227 disables the<br />
brake squeal sound effect.<br />
Page 80 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV186<br />
DCC Brake/Magnitude Timer<br />
Description<br />
This Value Controls DCC Brake Effect and Chuff Magnitude<br />
Activation<br />
Values<br />
0-255<br />
Initial Value<br />
1<br />
Related CVs<br />
CV46, CV185, CV200, CV201<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 1<br />
The decoder’s brake squeal effect plays when a speed step threshold<br />
is met (CV185). The threshold is met when the speed step decreases<br />
fast enough to meet this threshold (CV185). This value determines<br />
when the current speed step is sampled. Increasing this value<br />
decreases brake sensitivity.<br />
The decoders chuff magnitude increase and chuff magnitude<br />
decrease also uses the current speed step sampled at this time<br />
interval. See CV200 and CV201.<br />
Page 81 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV187<br />
DCC Uncouple Throttle Stop<br />
Description<br />
This Value Controls When the Uncouple Effect Plays<br />
Values<br />
0-255<br />
Initial Value<br />
3<br />
Related CVs<br />
CV37<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 1 1<br />
The decode plays the uncouple sound effects at this value of throttle<br />
stop if the uncouple sound is armed. Arm the uncouple effects by<br />
activating the uncouple Function when the engine is stopped.<br />
Page 82 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV188<br />
Pitch Shift<br />
Description<br />
This Value Controls the Total Pitch of all Sound Effects<br />
Values<br />
0-255<br />
Initial Value<br />
128<br />
Related CVs<br />
Bit 7 Bit 0<br />
1 0 0 0 0 0 0 0<br />
The decoder’s sound effects pitch is controlled by this value.<br />
Increasing this value increases all sound effect pitches. This value is<br />
updated in operations mode. Turn on the bell or set the whistle to<br />
the bell (CV35 = 4). With the whistle or bell on constantly, change<br />
this value and hear the pitch shift.<br />
Page 83 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV190<br />
Analog Sound Setup<br />
SETUP CVs<br />
Description<br />
This Value Contains Various Analog Sound Setup Features<br />
Values<br />
0-255<br />
Initial Value<br />
1-4<br />
Related CVs<br />
CV131, CV132, CV191, CV192<br />
Bit 7 Bit 0<br />
D7 D6 D5 D4 D3 D2 D1 D0<br />
This value is write Only. Prior to writing this value, use the<br />
DCMaster and save the desired track voltage. The voltage is saved<br />
by Muting the sounds, than Pressing AUX. The current track voltage<br />
is saved for later storage. Writing the following value to CV190<br />
indicates where the saved voltage is applied.<br />
Value What is saved Destination of Saved Track Voltage<br />
4 Analog Brake Release Voltage CV192<br />
3 Analog Brake Set Voltage CV191<br />
2 Shut Down Voltage CV132<br />
1 Sound Start Up Voltage CV131<br />
Page 84 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV191<br />
Analog Brake Set Voltage<br />
SETUP CVs<br />
Description<br />
This Value Sets the Track Voltage for Brake Set Sound Effect<br />
Values<br />
0-255<br />
Initial Value<br />
70<br />
Related CVs<br />
CV146, CV192<br />
Bit 7 Bit 0<br />
0 1 0 0 0 1 1 0<br />
The decoder’s analog brake set sound effect is activated when the<br />
track voltage reaches this value. Increasing this value increases the<br />
track voltage threshold needed before the brake set sound effect<br />
plays. Note: This value must be lower than the analog brake<br />
release voltage CV192.<br />
Page 85 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV192<br />
Analog Brake Release Voltage<br />
Description<br />
This Value Sets the Track Voltage for Brake Release Sound Effect<br />
Values<br />
0-255<br />
Initial Value<br />
77<br />
Related CVs<br />
CV147, CV191<br />
Bit 7 Bit 0<br />
0 1 0 0 1 1 0 1<br />
The decoder’s analog brake release sound effect is activated when the<br />
track voltage reaches this value. Increasing this value increases the<br />
track voltage threshold needed before the brake release sound effect<br />
plays. Note: This value must be higher than the analog brake set<br />
voltage CV191.<br />
Page 86 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV196<br />
<strong>Steam</strong> Cock Chuffs Event Count<br />
Description<br />
This Value Sets the <strong>Steam</strong> Cock Chuff Event Counter<br />
Values<br />
0-255<br />
Initial Value<br />
1<br />
Related CVs<br />
CV155<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 1<br />
The decoder’s steam cock chuffs sound effect is activated at the initial<br />
power up and after the engine is stopped from moving for 30<br />
seconds. This value determines how many sets of four chuffs or<br />
drive wheel revolutions this sound effect plays at initial motion<br />
before the normal chuffs start playing. Increasing this value increases<br />
the amount of steam cock chuffs at first motion while decreasing this<br />
values decrease the amount of steam cock chuffs. Setting this value<br />
to zero turns off this sound effect. CV155 controls the volume of this<br />
sound effect.<br />
Page 87 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV197<br />
Rod Knock Chuffs Event Count<br />
Description<br />
This Value Sets the Rod Knock Event Counter<br />
Values<br />
0-255<br />
Initial Value<br />
2<br />
Related CVs<br />
CV198, CV201, CV203<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 1 0<br />
The decoder’s rod knock sound effects play during a de-acceleration.<br />
This de-acceleration change is determined by CV203 for DC and<br />
CV201 for DCC. The automatic volume change is determined by<br />
CV198. The value for CV197, determines how many wheel<br />
revelations the rod knock chuff plays.<br />
Page 88 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV198<br />
Rod Knock Volume<br />
SETUP CVs<br />
Description<br />
This Value Sets the Rod Knock Volume Sound Effect<br />
Values<br />
0-255<br />
Initial Value<br />
80<br />
Related CVs<br />
CV197, CV201, CV203<br />
Bit 7 Bit 0<br />
0 1 0 1 0 0 0 0<br />
The decoder’s rod knock sound effects play during a de-acceleration.<br />
This de-acceleration change is determined by CV203 for DC and<br />
CV201 for DCC. The automatic volume change is determined by<br />
CV198. The value for CV197, determines how many wheel<br />
revelations the rod knock chuff plays. The rod knock volume is<br />
applied when the de-acceleration parameter is met. This volume is<br />
slowly returned back to its initial volume as the normal chuffs play.<br />
Page 89 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV199<br />
Chuff Magnitude Increase Volume<br />
Description<br />
This Value Sets Chuff Magnitude Increased Volume Sound Effect<br />
Values<br />
0-255<br />
Initial Value<br />
255<br />
Related CVs<br />
CV155, CV200, CV202<br />
Bit 7 Bit 0<br />
1 1 1 1 1 1 1 1<br />
The decoder’s chuff sound effects magnitude changes during<br />
acceleration. This acceleration is determined by CV202 for DC and<br />
CV200 for DCC. This value for CV199 determines the magnitude<br />
change from the normal chuff. Assume that CV155 is 100. If CV199<br />
is 200, than the magnitude difference is 100%. Note: If CV155 is set<br />
higher than CV199, than a magnitude difference will be difficult to<br />
hear.<br />
Page 90 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV200<br />
DCC Throttle Magnitude Increase<br />
Description<br />
This Value Sets the DCC Throttle Magnitude Increase Sound<br />
Values<br />
0-255<br />
Initial Value<br />
1<br />
Related CVs<br />
CV186, CV199, CV201<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 1<br />
An increasing change in throttle causes the chuff sound effects<br />
magnitude to increase. This value determines the throttle change<br />
over time that triggers this magnitude change in the chuff sound<br />
effect. CV186 determines the throttle sample time period. Increasing<br />
this value increases the throttle stops necessary over the timed period<br />
CV186 to trigger this event. Decreasing this value decreases the<br />
throttle stops necessary over the timed period CV186 to trigger this<br />
event.<br />
Page 91 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV201<br />
DCC Throttle Magnitude Decrease<br />
Description<br />
This Value Sets the DCC Throttle Magnitude Decrease Sound<br />
Values<br />
0-255<br />
Initial Value<br />
1<br />
Related CVs<br />
CV186, CV197, CV198, CV199, CV200<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 1<br />
A decreasing change in throttle causes the chuff sound effects<br />
magnitude to decrease. Also, the chuff sounds changes to a rod<br />
knock sound. See CV197 and CV198. This value, CV201, determines<br />
the throttle change over time that triggers this magnitude change in<br />
the chuff sound effect. CV186 determines the throttle sample time<br />
period. Increasing this value increases the throttle stops necessary<br />
over the timed period CV186 to trigger this event. Decreasing this<br />
value decreases the throttle stops necessary over the timed period<br />
CV186 to trigger this event.<br />
Page 92 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV202<br />
DC Track Change Magnitude Increase<br />
Description<br />
This Value Sets the DC Track Voltage Necessary for a Chuff<br />
Magnitude Increase<br />
Values<br />
0-255<br />
Initial Value<br />
160<br />
Related CVs<br />
CV199, CV203<br />
Bit 7 Bit 0<br />
1 0 1 0 0 0 0 0<br />
An increasing change in track voltage causes the chuff sound effects<br />
magnitude to increase. This value determines the track voltage<br />
increase necessary to trigger this event. Increasing this value<br />
increases the track voltage change necessary to trigger this event.<br />
Decreasing this value decreases the track voltage change necessary to<br />
trigger this event.<br />
Page 93 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV203<br />
DC Track Change Magnitude Decrease<br />
Description<br />
This Value Sets the DC Track Voltage Necessary for a Chuff<br />
Magnitude Decrease<br />
Values<br />
0-255<br />
Initial Value<br />
160<br />
Related CVs<br />
CV197, CV198, CV199, CV202<br />
Bit 7 Bit 0<br />
1 0 1 0 0 0 0 0<br />
A decreasing change in track voltage causes the chuff sound effects<br />
magnitude to decrease. Also, the chuff sounds changes to a rod<br />
knock sound. See CV197 and CV198. This value determines the track<br />
voltage decrease necessary to trigger this event. Increasing this value<br />
increases the track voltage change necessary to trigger this event.<br />
Decreasing this value decreases the track voltage change necessary to<br />
trigger this event.<br />
Page 94 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV204<br />
F5 Chuff Magnitude Change Increment<br />
Description<br />
This Value Sets the Change Increment for F5<br />
Values<br />
0-255<br />
Initial Value<br />
32<br />
Related CVs<br />
CV199, CV205<br />
Bit 7 Bit 0<br />
0 0 1 0 0 0 0 0<br />
Pressing the F5 or its assigned function key increases the chuff<br />
magnitude. Each successive press increases the chuff magnitude<br />
until the magnitude reaches 255%. This value determines the<br />
increase per press. The chuff magnitude automatically returns to its<br />
previous value over a time period.<br />
Page 95 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV205<br />
F6 Chuff Magnitude Change Decrement<br />
Description<br />
This Value Sets the Change Decrement for F6<br />
Values<br />
0-255<br />
Initial Value<br />
32<br />
Related CVs<br />
CV199, CV204<br />
Bit 7 Bit 0<br />
0 0 1 0 0 0 0 0<br />
Pressing the F6 or its assigned function key decreases the chuff<br />
magnitude. Each successive press decreases the chuff magnitude<br />
until the magnitude reaches 0%. This value determines the decrease<br />
per press. The chuff magnitude automatically returns to its previous<br />
value over a time period.<br />
Page 96 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV208<br />
DCC Cab Light Throttle Stop<br />
Description<br />
This Value Sets the Throttle Stop for Turning off the Cab Light<br />
Values<br />
0-255<br />
Initial Value<br />
3<br />
Related CVs<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 1 1<br />
The decoder’s Cab light is turned off at this value. A throttle stop<br />
below this value will turn on the Cab light.<br />
Page 97 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV209<br />
DCC Brake Set Throttle Stop<br />
Description<br />
This Value Sets the Throttle Stop for the Brake Set Sound Effect<br />
Values<br />
0-128<br />
Initial Value<br />
0<br />
Related CVs<br />
CV227<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 0<br />
`The decoder’s sound effect for brake set plays at this throttle stop<br />
if this effect is enabled.<br />
Page 98 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SETUP CVs<br />
CV210<br />
DCC Brake Release Throttle Stop<br />
Description<br />
This Value Sets the Throttle Stop for the Brake Release Sound Effect<br />
Values<br />
0-128<br />
Initial Value<br />
2<br />
Related CVs<br />
CV227<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 1 0<br />
The decoder’s sound effect for brake release plays at this throttle<br />
stop if this effect is enabled.<br />
Page 99 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV220<br />
Analog Control One<br />
CONTROL CVs<br />
Description<br />
This Value Contains Various Analog Control Bits<br />
Values<br />
0-255<br />
Initial Value<br />
3<br />
Related CVs<br />
CV160, CV221<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 1 1<br />
Bit7:<br />
Bit6:<br />
Bit5:<br />
Bit4:<br />
Bit3:<br />
Bit2:<br />
Bit1:<br />
Bit0:<br />
Not used<br />
Not used<br />
Not used<br />
0=L1 Does not Activate on Bell or Whistle<br />
1=L1 Activates on Bell or Whistle (See CV221)<br />
Not used<br />
Not used<br />
0=L1 Disabled<br />
1=L1 Enabled<br />
0=Front and Rear Lights Disabled<br />
1=Front and Rear Lights Enabled<br />
Page 100 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV221<br />
Analog Control Two<br />
CONTROL CVs<br />
Description<br />
This Value Contains Various Analog Control Bits<br />
Values<br />
0-255<br />
Initial Value<br />
0<br />
Related CVs<br />
CV220<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 0<br />
Bit7:<br />
Bit6:<br />
Bit5:<br />
Bit4:<br />
Bit3:<br />
Bit2:<br />
Bit1:<br />
Bit0:<br />
Not used<br />
Not used<br />
Not used<br />
Not used<br />
Not used<br />
Not used<br />
Not used<br />
0=Whistle Activates L1 (See Bit 4 CV220)<br />
1=Bell Activates L1 (See Bit 4 CV220)<br />
Page 101 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CONTROL CVs<br />
CV222<br />
Analog AUX Select for DCMaster<br />
Description<br />
This Value Sets the Function for AUX on the DCMaster<br />
Values<br />
0-255<br />
Initial Value<br />
0<br />
Related CVs<br />
CV220<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 0<br />
AUX Control<br />
Value<br />
Air Pump 0<br />
Coupler Sound Effects 1<br />
Front/Rear Light Control 2<br />
L1 Light Control 3<br />
Writing 0 allows the AUX key to play the air pump<br />
Writing 1 allows the AUX key to play the coupler sound effect<br />
Writing 2 allows the AUX to control the front and rear lights if<br />
CV220 bit 0 is set.<br />
Writing 3 allows the AUX to control L1 if CV220 bit 1 is set and<br />
CV220 bit 4 is cleared.<br />
Page 102 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV223<br />
DC Extended Consist Control<br />
CONTROL CVs<br />
Description<br />
This Value Controls Extended DC Consist Lighting<br />
Values<br />
0-255<br />
Initial Value<br />
135<br />
Related CVs<br />
CV19, CV21, CV22, CV221, CV222, CV224<br />
Bit 7 Bit 0<br />
1 0 0 0 0 1 1 1<br />
Bit7:<br />
Bit6:<br />
Bit5:<br />
Bit4:<br />
Bit3:<br />
Bit2:<br />
Bit1:<br />
Bit0:<br />
AUX Disabled=0; AUX Enabled=1<br />
Whistle Disabled=0; Whistle Enabled=1<br />
Bell Disabled=0; Bell Enabled=1<br />
Not used<br />
Not used<br />
L1 Disabled=0; L1 Enabled=1<br />
Front Light Disabled=0; Front Light Enabled=1<br />
Rear Light Disabled=0; Rear Light Enabled=1<br />
See Consist, a technical discussion<br />
Page 103 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CONTROL CVs<br />
CV224<br />
DC Easy Consist<br />
Description<br />
This Value Allows Convenient DC Consist Configuration<br />
Values<br />
1,2,3<br />
Initial Value<br />
0<br />
Related CVs<br />
CV19, V21, CV22, CV221, CV222, CV223<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 0<br />
The easy consist feature sets the decoder CV19 for consist 60 forward<br />
facing engine. Select 1, 2 or 3 for value to set the consist position.<br />
Values:<br />
0 = Consist Disabled<br />
1 = Front Engine<br />
Front light, L1 and AUX enabled (CV223)<br />
Whistle and Bell enabled<br />
2 = Middle Engine<br />
All lights and AUX disabled (CV223)<br />
Whistle and Bell disabled<br />
3 = Rear Engine<br />
Rear light enabled (CV223)<br />
Whistle and Bell disabled<br />
Page 104 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
The consist may be disabled by setting CV19 to zero or CV224 to<br />
zero. The AUX function setup (CV222) for DCMaster is honored in<br />
the consist. Using the Easy Consist feature allows a quick<br />
programming of a basic consist.<br />
Front Engine<br />
All lights are active accept the reverse light. The AUX function is<br />
enabled when the consist is addressed. The Whistle and Bell are<br />
enabled. If a change in the AUX function key is required, modify<br />
CV222. If a change in the lighting or Whistle or Bell is required<br />
modify CV223.<br />
Middle Engine<br />
All lights are inactive. The AUX function is disabled. The Whistle and<br />
Bell are disabled. If a change in the AUX function key is required,<br />
modify CV222. If a change in the lighting or Whisitle or Bell is<br />
required modify CV223.<br />
Rear Engine<br />
Only the reverse light is active. The Whistle, Bell and AUX are<br />
disabled. If a change in the AUX function key is required, modify<br />
CV222. If a change in the lighting or Whistle or Bell is required<br />
modify CV223.<br />
See Consist, a technical discussion<br />
Page 105 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CONTROL CVs<br />
CV225<br />
DCC Control One<br />
Description<br />
This Value Contains Various DCC Control Bits<br />
Values<br />
0-255<br />
Initial Value<br />
3<br />
Related CVs<br />
CV160, CV226<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 1 1<br />
Bit7:<br />
Bit6:<br />
Bit5:<br />
Bit4:<br />
Bit3:<br />
Bit2:<br />
Bit1:<br />
Bit0:<br />
Not used<br />
Not used<br />
Not used<br />
0=L1 Does not Activate on Bell or Whistle<br />
1=L1 Activates on Bell or Whistle (See CV226)<br />
Not used<br />
Not used<br />
0=L1 Disabled<br />
1=L1 Enabled<br />
0=Front and Rear Lights Disabled<br />
1=Front and Rear Lights Enabled<br />
Page 106 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CONTROL CVs<br />
CV226<br />
DCC Control Two<br />
Description<br />
This Value Contains Various DCC Control Bits<br />
Values<br />
0-255<br />
Initial Value<br />
0<br />
Related CVs<br />
CV225<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 0<br />
Bit7:<br />
Bit6:<br />
Bit5:<br />
Bit4:<br />
Bit3:<br />
Bit2:<br />
Bit1:<br />
Bit0:<br />
Not used<br />
Not used<br />
Not used<br />
Not used<br />
Not used<br />
Not used<br />
Not used<br />
0= Whistle Activates L1 (See Bit 4 CV225)<br />
1=Bell Activates L1 (See Bit 4 CV225)<br />
Page 107 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV227<br />
DCC Control Three<br />
CONTROL CVs<br />
Description<br />
This Value Contains Various DCC Control Bits<br />
Values<br />
0-255<br />
Initial Value<br />
3<br />
Related CVs<br />
CV130, CV160<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 1 1<br />
Bit7:<br />
Bit6:<br />
Bit5:<br />
Bit4:<br />
Bit3:<br />
Bit2:<br />
Bit1:<br />
Bit0:<br />
Not used<br />
Not used<br />
Not used<br />
Not used<br />
Not used<br />
Not used<br />
0=Brake Squeal Disabled on Quick Decelerations<br />
1=Brake Squeal Automatic on Quick Decelerations<br />
0=Brake Set and Brake Release Disabled on Throttle<br />
Stop Zero Transitions<br />
1=Brake Set and Brake Release Automatic on Throttle<br />
Stop Zero Transitions<br />
Page 108 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV228<br />
DCC Startup Timer<br />
CONTROL CVs<br />
Description<br />
This Value Contains the DCC Startup Timer<br />
Values<br />
0-255<br />
Initial Value<br />
1<br />
Related CVs<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 1<br />
On power up, the decoder will wait this much time in seconds to<br />
detect the DCC system. If this value is too low, DC mode will start<br />
the system resulting in strange behavior. The initial value is 1 second.<br />
Page 109 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CONTROL CVs<br />
CV229<br />
DCC Extended Consist Lighting<br />
Description<br />
This Value Controls Extended DCC Consist Lighting<br />
Values<br />
0-255<br />
Initial Value<br />
135<br />
Related CVs<br />
CV19, CV21, CV22<br />
Bit 7 Bit 0<br />
1 0 0 0 0 1 1 1<br />
Bit7:<br />
Bit6:<br />
Bit5:<br />
Bit4:<br />
Bit3:<br />
Bit2:<br />
Bit1:<br />
Bit0:<br />
Cab Disabled=0; Cab Enabled=1<br />
Not used<br />
Not used<br />
Not used<br />
Not used<br />
L1 Disabled=0; L1 Enabled=1<br />
Front Light Disabled=0; Front Light Enabled=1<br />
Rear Light Disabled=0; Rear Light Enabled=1<br />
See Consist, a technical discussion<br />
Page 110 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV230<br />
DCC Easy Consist<br />
CONTROL CVs<br />
Description<br />
This Value Allows Convenient DCC Consist Configuration<br />
Values<br />
1,2,3<br />
Initial Value<br />
0<br />
Related CVs<br />
CV19, CV21, CV22, CV229<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 0<br />
The easy consist feature sets the decoder CV19 for consist 60 forward<br />
facing engine. Select 1, 2 or 3 for value to set the consist position.<br />
Values:<br />
0 = Consist Disabled<br />
1 = Front Engine<br />
All consist function keys enabled (CV21, CV22)<br />
All lights except the rear light enabled (CV229)<br />
2 = Middle Engine<br />
All consist function keys except F0, F8 and F9<br />
disabled (CV21, CV22); All lights disabled (CV229)<br />
3 = Rear Engine<br />
All consist function keys except F0, F8 and F9<br />
disabled (CV21, CV22)<br />
Only rear light enabled (CV229)<br />
Page 111 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
The consist may be disabled by setting CV19 to zero or CV230 to<br />
zero. No CV’s may be changed when the consist is addressed. The<br />
engine in a consist must be addressed when modifying its CV. All<br />
function keys are honored by addressing the engine. Additionally,<br />
function keys enabled by CV21 and CV22 are honored by addressing<br />
the consist. Using the Easy Consist feature allows a quick<br />
programming of a basic consist.<br />
Front Engine<br />
All lights are active accept the reverse light. If a change in this<br />
lighting is required, modify CV299 for the appropriate lighting<br />
changes. All functions keys are enable when the consist is addressed.<br />
If a change in active function keys are required, modify CV21 and<br />
CV22.<br />
Middle Engine<br />
All lights are inactive. If a change in this lighting is required, modify<br />
CV299 for the appropriate lighting changes. All functions keys are<br />
disabled except F0 (Headlight), F8 (Mute-Volume) and F9 (Startup)<br />
when the consist is addressed. If a change in active function keys are<br />
required, modify CV21 and CV22.<br />
Rear Engine<br />
Only the reverse light is active. If a change in this lighting is required,<br />
modify CV299 for the appropriate lighting changes. All functions<br />
keys are disabled except F0 (Headlight), F8 (Mute-Volume) and F9<br />
(Startup) when the consist is addressed. If a change in active function<br />
keys are required, modify CV21 and CV22.<br />
See Consist, a technical discussion<br />
Page 112 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CONTROL CVs<br />
CV240<br />
Random Sound Effect Generator Occurrence<br />
Description<br />
This Value Contains the DCC Startup Timer<br />
Values<br />
1-30<br />
Initial Value<br />
24<br />
Related CVs<br />
Bit 7 Bit 0<br />
0 0 0 1 1 0 0 0<br />
This value determines how often random sound effects occur.<br />
Increasing this value decreases the occurrences of random sound<br />
effects.<br />
Page 113 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CV245<br />
General System Controls<br />
CONTROL CVs<br />
Description<br />
This Value Contains General Bits as Defined<br />
Values<br />
0-255<br />
Initial Value<br />
1<br />
Related CVs<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 0 1<br />
These bit value control the following:<br />
D0 – 0=Whistle Alternative Ending Disabled<br />
1=Whistle Alternative Ending Enabled<br />
Page 114 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CONTROL CVs<br />
CV248<br />
Enhanced DC Motor Startup Delay<br />
Description<br />
This Value Contains the Motor Startup Delay<br />
Values<br />
0-63<br />
Initial Value<br />
8<br />
Related CVs<br />
Bit 7 Bit 0<br />
0 0 0 0 1 0 0 0<br />
This value creates a powerup motor delay. Decreasing this value<br />
causes a delay in when the motor receives power. This value allows<br />
closer synchronization between sounds and user actions.<br />
Page 115 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CONTROL CVs<br />
CV249<br />
Enhanced DC Motor Control Momentum<br />
Description<br />
This Value Contains the Motor Momentum<br />
Values<br />
0-255<br />
Initial Value<br />
2<br />
Related CVs<br />
Bit 7 Bit 0<br />
0 0 0 0 0 0 1 0<br />
This value creates a motor delay in responding to track voltage<br />
changes. Increasing this value slows the response to changing track<br />
voltages while decreasing this value increases the response to<br />
changing track voltages. This value allows closer synchronization<br />
between sounds and user actions. Only the motor response is slowed<br />
by this value.<br />
Page 116 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CONTROL CVs<br />
CV250<br />
Enhanced DC Motor Track Voltage Momentum<br />
Description<br />
This Value Contains the Track Voltage Momentum<br />
Values<br />
1-255<br />
Initial Value<br />
10<br />
Related CVs<br />
Bit 7 Bit 0<br />
0 0 0 0 1 0 1 0<br />
This value creates a delay in the digitally filtered track voltage.<br />
Increasing this value slows the response to changing track voltages<br />
while decreasing this value increases the response to changing track<br />
voltages. Sound and motor response varies with the change in this<br />
value.<br />
Page 117 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CONTROL CVs<br />
CV251<br />
Enhanced DC Motor Control Vmax<br />
Description<br />
This Value Contains the Motor Finish Track Voltage<br />
Values<br />
0-255<br />
Initial Value<br />
144<br />
Related CVs<br />
CV 252, CV253<br />
Bit 7 Bit 0<br />
1 0 0 1 0 0 0 0<br />
Vmax is the track voltage that once reached allows 100% track power<br />
to the motor. Increasing Vmax means a higher track voltage is<br />
needed before all track power is supplied to the motor. Decreasing<br />
Vmax means full power to the motor at a lower track voltage.<br />
Note: Vmax must be greater than Vmin.<br />
See Advanced DC Motor Control<br />
Page 118 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CONTROL CVs<br />
CV252<br />
Enhanced DC Motor Control Vmin<br />
Description<br />
This Value Contains the Motor Start Track Voltage<br />
Values<br />
0-255<br />
Initial Value<br />
80<br />
Related CVs<br />
CV 251, CV253<br />
Bit 7 Bit 0<br />
0 1 0 1 0 0 0 0<br />
Vmin defines the track voltage that applies the lowest or starting<br />
motor power. The power applied at this voltage is the Dmin. Valid<br />
values for Vmin is from 0-255. Decreasing Vmin means a higher track<br />
voltage becomes necessary before the train begins to move.<br />
Increasing Vmin means the train begins to move at a lower track<br />
voltage. Vmin and Dmin work together to determine the initial<br />
motor power at the start voltage for train movement.<br />
Note: Vmin must be less than Vmax.<br />
See Advanced DC Motor Control<br />
Page 119 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
CONTROL CVs<br />
CV253<br />
Enhanced DC Motor Control Dmin<br />
Description<br />
This Value Contains the Motor Start Duty Cycle<br />
Values<br />
0-255<br />
Initial Value<br />
50<br />
Related CVs<br />
CV 251, CV252<br />
Bit 7 Bit 0<br />
0 0 1 1 0 0 1 0<br />
Dmin defines the minimal duty cycled responsible for Vmin motor<br />
power. Increasing this value will cause more motor power at Vmin<br />
while decreasing this value causes less motor power at Vmin.<br />
See Advanced DC Motor Control<br />
Page 120 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Advanced DC Motor Control<br />
Dc operation with sounds creates a dilemma. The train usually will start moving at a very low<br />
track voltage, to low to power a loudspeaker with high quality sounds. A higher voltage of<br />
operation for the motor is an acceptable solution. About 6-7 volts is necessary before this sound<br />
system can function, producing loud, high quality sounds, with the motor powered and the train<br />
beginning to move. This advanced motor controller gives acceptable motor control at the<br />
necessary power levels, allowing the sound system to start at a much lower voltage, keeping the<br />
motor from stealing the power from the sound system until enough power exists to move the<br />
train without the sounds degrading or shutting off. Also, more overall power is diverted to the<br />
motor at top speeds. The maximum train speed is higher with this advanced DC motor<br />
controller.<br />
The DC motor controller may be altered by changing the power curve. CV251, CV252 and<br />
CV253 control the slope, intercept and initial motor power. Altering these values changes the<br />
trains startup behavior relative to track voltage and at what voltage full track power is applied to<br />
the motor.<br />
Vmin<br />
Vmin defines the track voltage that applies the lowest or starting motor power. Valid values for<br />
Vmin is from 0-255. The distance between Vmin and Vmax (Vmax > Vmin) distributes motor<br />
power from Dmin (Applied Duty Cycle) at Vmin until Vmax where 100% of the power from the<br />
track is applied.<br />
Note: Vmin < Vmax. Too low a value for Vmin may cause the sound unit to reset when<br />
power is supplied to the motor.<br />
Vmax<br />
Vmax is the track voltage that once reached allows 100% track power to the motor. Valid values<br />
for Vmax is from 0-255. Increasing Vmax means a higher track voltage is needed before all track<br />
power is supplied to the motor. Decreasing Vmax means full power to the motor at a lower track<br />
voltage.<br />
Note: Vmax > Vin. Too high a value for Vmax may not allow the train to reach full speed.<br />
Dmin<br />
Dmin defines the minimal duty cycled responsible for Vmin motor power. Valid values are from<br />
1 to 63. The initial value is 44. Increasing this value will cause more motor power at Vmin<br />
while decreasing this value causes less motor power at Vmin.<br />
Note: Too high a value for Dmin may cause the sound unit to reset when power is supplied<br />
to the motor<br />
Page 121 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Advanced DC Motor Control<br />
Figure one illustrates a motor connected directly to track power and a motor connected to the<br />
advanced motor controller. The sound unit supplies full sound volume at about 5.5 volts. Motor<br />
power is supplied around 6 volts. Between 6 volts and 12 volts, the sound unit monitors the track<br />
voltage and proportionately increase or decreases the motor power as noted by the slope of the<br />
enhanced curve in figure one. At about 12 volts, all power is applied to the motor. The train<br />
motor is now for all practically purposes, connected directly to the track. Note that 100% power<br />
is not applied. The loss is due to the power control device. You will note that the maximum<br />
train speed will be faster with the enhanced DC motor controller than most DC decoders. This<br />
loss illustrated in the curve is much less with the enhanced DC motor controller.<br />
Motor Power<br />
Advanced DC Motor Controller<br />
Power Curve<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
0<br />
Normal<br />
Enhanced<br />
2 4 6 8 10 12 14 16 18<br />
Track Voltage<br />
Figure 1<br />
Page 122 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
SYSTEM CVs<br />
CV Description Initial Yours<br />
1 Primary Address 3<br />
7 Manufacturer Version ?<br />
8 Manufacturer ID 38<br />
15 Unlock ID Code 0<br />
16 Lock ID Number 0<br />
17 Extended Address MSB 192<br />
18 Extended Address LSB 128<br />
19 Consist Address 0<br />
21 Consist Functions Type 0 255<br />
22 Consist Functions Type1 255<br />
29 Configuration Bits 2<br />
Page 123 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
FUNCTION CVs<br />
CV Description Initial Yours<br />
33 F0(f) (Front Lamp) 1<br />
34 F0(r) (Rear Lamp) 2<br />
35 F1 (Bell) 16<br />
36 F2 (Whistle) 4<br />
37 F3 (Couple/Uncouple) 32<br />
38 F4 (Air Pump) 8<br />
39 F5 (Blown/Increase Chuff Magnitude) 16<br />
40 F6 (Water Fill/Decrease Chuff Magnitude) 32<br />
41 F7 (L1 Visual Effects) 64<br />
42 F8 (Master Analog Volume) 128<br />
43 F9 (Shutdown and Startup) 16<br />
44 F10 (Shovel Coal) 32<br />
45 F11 (Water Injector) 64<br />
46 F12 (Brake Set/Release) 128<br />
Page 124 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Sound CVs<br />
CV Description Initial Yours<br />
130 Master Volume Sound Increment 2<br />
131 Analog Sound Unit Startup Voltage 56<br />
132 Analog Sound Unit Shutdown Voltage 54<br />
133 Sound Unit Master Volume 15<br />
135 Whistle Volume 100<br />
136 Bell Volume 100<br />
137 <strong>Steam</strong> Volume 100<br />
138 Horn Volume 100<br />
140 Couple Volume 100<br />
141 Uncouple Volume 100<br />
143 Air Pump Volume 100<br />
144 Blow Down Volume 100<br />
145 <strong>Steam</strong> Cock Volume 100<br />
146 Brake Set Volume 100<br />
147 Brake Release Volume 100<br />
148 Pop Off Valve Volume 100<br />
149 Blower Volume 100<br />
150 Dynamo Volume 100<br />
151 Brake Squeal Volume 100<br />
152 Shovel Coal Volume 100<br />
153 Water Fill Volume 100<br />
154 Water Injector Volume 100<br />
155 Chuff Volume 100<br />
Page 125 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
LIGHTING CVs<br />
CV Description Initial Yours<br />
159 System Lighting 0<br />
160 L1 Light Definition Varies<br />
161 L1 Parameter 1 Varies<br />
162 L1 Parameter 2 Varies<br />
163 L1 Parameter 3 Varies<br />
164 L1 Parameter 4 Varies<br />
Page 126 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Setup CVs<br />
CV Description Initial Yours<br />
180 Bell Ring Interval Varies<br />
181 Whistle Fade In Varies<br />
182 Whistle Fade Out Varies<br />
183 Whistle Fade In Level Varies<br />
184 Analog Brake Control 64<br />
185 DCC Brake Control 20<br />
186 DCC Brake Timer 1<br />
187 DCC Uncouple Throttle Stop 3<br />
188 Pitch Shift 128<br />
190 Analog Sound Setup x<br />
191 Analog Brake Set Voltage 70<br />
192 Analog Brake Release Voltage 77<br />
196 <strong>Steam</strong> Cock Chuffs Event Count 1<br />
197 Rod Knock Chuffs Event Count 2<br />
198 Rod Knock Volume 80<br />
199 Chuff Magnitude Increase Volume 255<br />
200 DCC Throttle Magnitude Increase 1<br />
201 DCC Throttle Magnitude Decrease 1<br />
202 DC Track Change Magnitude Increase 160<br />
203 DC Track Change Magnitude Decrease 160<br />
204 F5 Chuff Magnitude Change Increment 32<br />
205 F6 Chuff Magnitude Change Decrement 32<br />
Page 127 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Setup CVs<br />
208 DCC Cab Light Throttle Stop 3<br />
209 DCC Brake Set Throttle Stop 0<br />
210 DCC Brake Release Throttle Stop 2<br />
Page 128 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Control CVs<br />
CV Description Initial Yours<br />
220 Analog Control One 3<br />
221 Analog Control Two 0<br />
222 Analog AUX Select for DCMaster 0<br />
223 DC Extended Consist Control 135<br />
224 DC Easy Consist 0<br />
225 DCC Control One 3<br />
226 DCC Control Two 0<br />
227 DCC Control Three 3<br />
228 DCC Start Up Timer 1<br />
229 DCC Extended Consist Lighting 135<br />
230 DCC Easy Consist 0<br />
240 Random Sound Generator Occurrence 24<br />
245 General System Controls 1<br />
248 Enhanced DC Motor Startup Delay 8<br />
249 Enhanced DC Motor Control Momentum 2<br />
250 Enhanced DC Motor Track Voltage Momentum 10<br />
251 Enhanced DC Motor Control Vmax 144<br />
252 Enhanced DC Motor Control Vmin 80<br />
253 Enhanced DC Motor Control Dmin 50<br />
Page 129 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
DCC CVs<br />
CV Description Initial Yours<br />
1 Primary Address 3<br />
7 Manufacturer Version ?<br />
8 Manufacturer ID 38<br />
15 Unlock ID Code 0<br />
16 Lock ID Number 0<br />
17 Extended Address MSB 192<br />
18 Extended Address LSB 128<br />
19 Consist Address 0<br />
21 Consist Functions Type 0 255<br />
22 Consist Functions Type1 255<br />
29 Configuration Bits 2<br />
33 F0(f) (Front Lamp) 1<br />
34 F0(r) (Rear Lamp) 2<br />
35 F1 (Bell) 16<br />
36 F2 (Whistle) 4<br />
37 F3 (Couple/Uncouple) 32<br />
38 F4 (Air Pump) 8<br />
39 F5 (Blown/Increase Chuff Magnitude) 16<br />
40 F6 (Water Fill/Decrease Chuff Magnitude) 32<br />
41 F7 (L1 Visual Effects) 64<br />
42 F8 (Master Analog Volume) 128<br />
43 F9 (Shutdown and Startup) 16<br />
44 F10 (Shovel Coal) 32<br />
45 F11 (Water Injector) 64<br />
46 F12 (Brake Set/Release) 128<br />
Page 130 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
DCC CVs<br />
CV Description Initial Yours<br />
130 Master Volume Sound Increment 2<br />
131 Analog Sound Unit Startup Voltage 56<br />
132 Analog Sound Unit Shutdown Voltage 54<br />
133 Sound Unit Master Volume 15<br />
135 Whistle Volume 100<br />
136 Bell Volume 100<br />
137 <strong>Steam</strong> Volume 100<br />
138 Horn Volume 100<br />
140 Couple Volume 100<br />
141 Uncouple Volume 100<br />
143 Air Pump Volume 100<br />
144 Blow Down Volume 100<br />
145 <strong>Steam</strong> Cock Volume 100<br />
146 Brake Set Volume 100<br />
147 Brake Release Volume 100<br />
148 Pop Off Valve Volume 100<br />
149 Blower Volume 100<br />
150 Dynamo Volume 100<br />
151 Brake Squeal Volume 100<br />
152 Shovel Coal Volume 100<br />
153 Water Fill Volume 100<br />
154 Water Injector Volume 100<br />
155 Chuff Volume 100<br />
Page 131 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
DCC CVs<br />
CV Description Initial Yours<br />
159 System Lighting 0<br />
160 L1 Light Definition Varies<br />
161 L1 Parameter 1 Varies<br />
162 L1 Parameter 2 Varies<br />
163 L1 Parameter 3 Varies<br />
164 L1 Parameter 4 Varies<br />
180 Bell Ring Interval Varies<br />
181 Whistle Fade In Varies<br />
182 Whistle Fade Out Varies<br />
183 Whistle Fade In Level Varies<br />
185 DCC Brake Control 20<br />
186 DCC Brake Timer 1<br />
187 DCC Uncouple Throttle Stop 3<br />
188 Pitch Shift 128<br />
196 <strong>Steam</strong> Cock Chuffs Event Count 1<br />
197 Rod Knock Chuffs Event Count 2<br />
198 Rod Knock Volume 80<br />
199 Chuff Magnitude Increase Volume 255<br />
200 DCC Throttle Magnitude Increase 1<br />
201 DCC Throttle Magnitude Decrease 1<br />
202 DC Track Change Magnitude Increase 160<br />
203 DC Track Change Magnitude Decrease 160<br />
204 F5 Chuff Magnitude Change Increment 32<br />
205 F6 Chuff Magnitude Change Decrement 32<br />
Page 132 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
DCC CVs<br />
208 DCC Cab Light Throttle Stop 3<br />
209 DCC Brake Set Throttle Stop 0<br />
210 DCC Brake Release Throttle Stop 2<br />
225 DCC Control One 3<br />
226 DCC Control Two 0<br />
227 DCC Control Three 3<br />
228 DCC Start Up Timer 1<br />
229 DCC Extended Consist Lighting 135<br />
230 DCC Easy Consist 0<br />
240 Random Sound Generator Occurrence 24<br />
245 General System Controls 1<br />
Page 133 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
DC CVs<br />
CV Description Initial Yours<br />
15 Unlock ID Code 0<br />
16 Lock ID Number 0<br />
19 Consist Address 0<br />
29 Configuration Bits 2<br />
130 Master Volume Sound Increment 2<br />
131 Analog Sound Unit Startup Voltage 56<br />
132 Analog Sound Unit Shutdown Voltage 54<br />
133 Sound Unit Master Volume 15<br />
135 Whistle Volume 100<br />
136 Bell Volume 100<br />
137 <strong>Steam</strong> Volume 100<br />
138 Horn Volume 100<br />
140 Couple Volume 100<br />
141 Uncouple Volume 100<br />
143 Air Pump Volume 100<br />
144 Blow Down Volume 100<br />
145 <strong>Steam</strong> Cock Volume 100<br />
146 Brake Set Volume 100<br />
147 Brake Release Volume 100<br />
148 Pop Off Valve Volume 100<br />
149 Blower Volume 100<br />
150 Dynamo Volume 100<br />
151 Brake Squeal Volume 100<br />
152 Shovel Coal Volume 100<br />
153 Water Fill Volume 100<br />
Page 134 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
DC CVs<br />
CV Description Initial Yours<br />
154 Water Injector Volume 100<br />
155 Chuff Volume 100<br />
159 System Lighting 0<br />
160 L1 Light Definition Varies<br />
161 L1 Parameter 1 Varies<br />
162 L1 Parameter 2 Varies<br />
163 L1 Parameter 3 Varies<br />
164 L1 Parameter 4 Varies<br />
180 Bell Ring Interval Varies<br />
181 Whistle Fade In Varies<br />
182 Whistle Fade Out Varies<br />
183 Whistle Fade In Level Varies<br />
184 Analog Brake Control 64<br />
188 Pitch Shift 128<br />
190 Analog Sound Setup x<br />
191 Analog Brake Set Voltage 70<br />
192 Analog Brake Release Voltage 77<br />
196 <strong>Steam</strong> Cock Chuffs Event Count 1<br />
197 Rod Knock Chuffs Event Count 2<br />
198 Rod Knock Volume 80<br />
199 Chuff Magnitude Increase Volume 255<br />
202 DC Track Change Magnitude Increase 160<br />
203 DC Track Change Magnitude Decrease 160<br />
220 Analog Control One 3<br />
221 Analog Control Two 0<br />
Page 135 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
DC CVs<br />
222 Analog AUX Select for DCMaster 0<br />
223 DC Extended Consist Control 135<br />
224 DC Easy Consist 0<br />
240 Random Sound Generator Occurrence 24<br />
245 General System Controls 1<br />
248 Enhanced DC Motor Startup Delay 8<br />
249 Enhanced DC Motor Control Momentum 2<br />
250 Enhanced DC Motor Track Voltage Momentum 10<br />
251 Enhanced DC Motor Control Vmax 144<br />
252 Enhanced DC Motor Control Vmin 80<br />
253 Enhanced DC Motor Control Dmin 50<br />
Page 136 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Decimal to Binary Primer<br />
Setting CV’s<br />
Setting the CV’s requires knowledge of conversion between binary<br />
and decimal. The following examples demonstrates the conversion<br />
process from binary to decimal after determining which bits in a CV<br />
need to be “1” and which needs to be “0”. The tables are also useful<br />
for converting binary to decimal.<br />
Reading CV’s<br />
The tables are also useful for converting decimal to binary when<br />
reading the CV’s in service mode. After reading the CV, use the<br />
tables to determine which bits are “1” and which bits are “0”. Once<br />
the bit patterns are identified, find the CV in this manual to<br />
determine what functions are controlled by the bits.<br />
Bit 7 Bit 0<br />
2 7 2 6 2 5 2 4 2 3 2 2 2 1 2 0<br />
128 64 32 16 8 4 2 1<br />
Consider a binary number 10001011<br />
128+0+0+0+8+0+2+1=139<br />
Consider a binary number 00011101<br />
0+0+0+16+8+4+0+1=29<br />
CVxx read is 39. Table lookup is: 00100111<br />
Page 137 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
Page 138 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00<br />
Decimal to Hexadecimal Conversion<br />
Dec Hex Oct Bin<br />
0<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
0<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
000<br />
001<br />
002<br />
003<br />
004<br />
005<br />
006<br />
007<br />
010<br />
011<br />
012<br />
013<br />
014<br />
015<br />
016<br />
017<br />
00000000<br />
00000001<br />
00000010<br />
00000011<br />
00000100<br />
00000101<br />
00000110<br />
00000111<br />
00001000<br />
00001001<br />
00001010<br />
00001011<br />
00001100<br />
00001101<br />
00001110<br />
00001111<br />
Dec Hex Oct Bin<br />
16<br />
17<br />
18<br />
19<br />
20<br />
21<br />
22<br />
23<br />
24<br />
25<br />
26<br />
27<br />
28<br />
29<br />
30<br />
31<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
1A<br />
1B<br />
1C<br />
1D<br />
1E<br />
1F<br />
020<br />
021<br />
022<br />
023<br />
024<br />
025<br />
026<br />
027<br />
030<br />
031<br />
032<br />
033<br />
034<br />
035<br />
036<br />
037<br />
00010000<br />
00010001<br />
00010010<br />
00010011<br />
00010100<br />
00010101<br />
00010110<br />
00010111<br />
00011000<br />
00011001<br />
00011010<br />
00011011<br />
00011100<br />
00011101<br />
00011110<br />
00011111<br />
Dec Hex Oct Bin<br />
32<br />
33<br />
34<br />
35<br />
36<br />
37<br />
38<br />
39<br />
40<br />
41<br />
42<br />
43<br />
44<br />
45<br />
46<br />
47<br />
20<br />
21<br />
22<br />
23<br />
24<br />
25<br />
26<br />
27<br />
28<br />
29<br />
2A<br />
2B<br />
2C<br />
2D<br />
2E<br />
2F<br />
040<br />
041<br />
042<br />
043<br />
044<br />
045<br />
046<br />
047<br />
050<br />
051<br />
052<br />
053<br />
054<br />
055<br />
056<br />
057<br />
00100000<br />
00100001<br />
00100010<br />
00100011<br />
00100100<br />
00100101<br />
00100110<br />
00100111<br />
00101000<br />
00101001<br />
00101010<br />
00101011<br />
00101100<br />
00101101<br />
00101110<br />
00101111<br />
Dec Hex Oct Bin<br />
48<br />
49<br />
50<br />
51<br />
52<br />
53<br />
54<br />
55<br />
56<br />
57<br />
58<br />
59<br />
60<br />
61<br />
62<br />
63<br />
30<br />
31<br />
32<br />
33<br />
34<br />
35<br />
36<br />
37<br />
38<br />
39<br />
3A<br />
3B<br />
3C<br />
3D<br />
3E<br />
3F<br />
060<br />
061<br />
062<br />
063<br />
064<br />
065<br />
066<br />
067<br />
070<br />
071<br />
072<br />
073<br />
074<br />
075<br />
076<br />
077<br />
00110000<br />
00110001<br />
00110010<br />
00110011<br />
00110100<br />
00110101<br />
00110110<br />
00110111<br />
00111000<br />
00111001<br />
00111010<br />
00111011<br />
00111100<br />
00111101<br />
00111110<br />
00111111<br />
Dec Hex Oct Bin<br />
64<br />
65<br />
66<br />
67<br />
68<br />
69<br />
70<br />
71<br />
72<br />
73<br />
74<br />
75<br />
76<br />
77<br />
78<br />
79<br />
40<br />
41<br />
42<br />
43<br />
44<br />
45<br />
46<br />
47<br />
48<br />
49<br />
4A<br />
4B<br />
4C<br />
4D<br />
4E<br />
4F<br />
100<br />
101<br />
102<br />
103<br />
104<br />
105<br />
106<br />
107<br />
110<br />
111<br />
112<br />
113<br />
114<br />
115<br />
116<br />
117<br />
01000000<br />
01000001<br />
01000010<br />
01000011<br />
01000100<br />
01000101<br />
01000110<br />
01000111<br />
01001000<br />
01001001<br />
01001010<br />
01001011<br />
01001100<br />
01001101<br />
01001110<br />
01001111<br />
Dec Hex Oct Bin<br />
80<br />
81<br />
82<br />
83<br />
84<br />
85<br />
86<br />
87<br />
88<br />
89<br />
90<br />
91<br />
92<br />
93<br />
94<br />
95<br />
50<br />
51<br />
52<br />
53<br />
54<br />
55<br />
56<br />
57<br />
58<br />
59<br />
5A<br />
5B<br />
5C<br />
5D<br />
5E<br />
5F<br />
120<br />
121<br />
122<br />
123<br />
124<br />
125<br />
126<br />
127<br />
130<br />
131<br />
132<br />
133<br />
134<br />
135<br />
136<br />
137<br />
01010000<br />
01010001<br />
01010010<br />
01010011<br />
01010100<br />
01010101<br />
01010110<br />
01010111<br />
01011000<br />
01011001<br />
01011010<br />
01011011<br />
01011100<br />
01011101<br />
01011110<br />
01011111
Page 139 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00<br />
Decimal to Hexadecimal Conversion<br />
Dec Hex Oct Bin<br />
112<br />
113<br />
114<br />
115<br />
116<br />
117<br />
118<br />
119<br />
120<br />
121<br />
122<br />
123<br />
124<br />
125<br />
126<br />
127<br />
70<br />
71<br />
72<br />
73<br />
74<br />
75<br />
76<br />
77<br />
78<br />
79<br />
7A<br />
7B<br />
7C<br />
7D<br />
7E<br />
7F<br />
160<br />
161<br />
162<br />
163<br />
164<br />
165<br />
166<br />
167<br />
170<br />
171<br />
172<br />
173<br />
174<br />
175<br />
176<br />
177<br />
01110000<br />
01110001<br />
01110010<br />
01110011<br />
01110100<br />
01110101<br />
01110110<br />
01110111<br />
01111000<br />
01111001<br />
01111010<br />
01111011<br />
01111100<br />
01111101<br />
01111110<br />
01111111<br />
Dec Hex Oct Bin<br />
128<br />
129<br />
130<br />
131<br />
132<br />
133<br />
134<br />
135<br />
136<br />
137<br />
138<br />
139<br />
140<br />
141<br />
142<br />
143<br />
80<br />
81<br />
82<br />
83<br />
84<br />
85<br />
86<br />
87<br />
88<br />
89<br />
8A<br />
8B<br />
8C<br />
8D<br />
8E<br />
8F<br />
200<br />
201<br />
202<br />
203<br />
204<br />
205<br />
206<br />
207<br />
210<br />
211<br />
212<br />
213<br />
214<br />
215<br />
216<br />
217<br />
10000000<br />
10000001<br />
10000010<br />
10000011<br />
10000100<br />
10000101<br />
10000110<br />
10000111<br />
10001000<br />
10001001<br />
10001010<br />
10001011<br />
10001100<br />
10001101<br />
10001110<br />
10001111<br />
Dec Hex Oct Bin<br />
96<br />
97<br />
98<br />
99<br />
100<br />
101<br />
102<br />
103<br />
104<br />
105<br />
106<br />
107<br />
108<br />
109<br />
110<br />
111<br />
60<br />
61<br />
62<br />
63<br />
64<br />
65<br />
66<br />
67<br />
68<br />
69<br />
6A<br />
6B<br />
6C<br />
6D<br />
6E<br />
6F<br />
140<br />
141<br />
142<br />
143<br />
144<br />
145<br />
146<br />
147<br />
150<br />
151<br />
152<br />
153<br />
154<br />
155<br />
156<br />
157<br />
01100000<br />
01100001<br />
01100010<br />
01100011<br />
01100100<br />
01100101<br />
01100110<br />
01100111<br />
01101000<br />
01101001<br />
01101010<br />
01101011<br />
01101100<br />
01101101<br />
01101110<br />
01101111<br />
Dec Hex Oct Bin<br />
144<br />
145<br />
146<br />
147<br />
148<br />
149<br />
150<br />
151<br />
152<br />
153<br />
154<br />
155<br />
156<br />
157<br />
158<br />
159<br />
90<br />
91<br />
92<br />
93<br />
94<br />
95<br />
96<br />
97<br />
98<br />
99<br />
9A<br />
9B<br />
9C<br />
9D<br />
9E<br />
9F<br />
220<br />
221<br />
222<br />
223<br />
224<br />
225<br />
226<br />
227<br />
230<br />
231<br />
232<br />
233<br />
234<br />
235<br />
236<br />
237<br />
10010000<br />
10010001<br />
10010010<br />
10010011<br />
10010100<br />
10010101<br />
10010110<br />
10010111<br />
10011000<br />
10011001<br />
10011010<br />
10011011<br />
10011100<br />
10011101<br />
10011110<br />
10011111<br />
Dec Hex Oct Bin<br />
160<br />
161<br />
162<br />
163<br />
164<br />
165<br />
166<br />
167<br />
168<br />
169<br />
170<br />
171<br />
172<br />
173<br />
174<br />
175<br />
A0<br />
A1<br />
A2<br />
A3<br />
A4<br />
A5<br />
A6<br />
A7<br />
A8<br />
A9<br />
AA<br />
AB<br />
AC<br />
AD<br />
AE<br />
AF<br />
240<br />
241<br />
242<br />
243<br />
244<br />
245<br />
246<br />
247<br />
250<br />
251<br />
252<br />
253<br />
254<br />
255<br />
256<br />
257<br />
10100000<br />
10100001<br />
10100010<br />
10100011<br />
10100100<br />
10100101<br />
10100110<br />
10100111<br />
10101000<br />
10101001<br />
10101010<br />
10101011<br />
10101100<br />
10101101<br />
10101110<br />
10101111<br />
Dec Hex Oct Bin<br />
176<br />
177<br />
178<br />
179<br />
180<br />
181<br />
182<br />
183<br />
184<br />
185<br />
186<br />
187<br />
188<br />
189<br />
190<br />
191<br />
B0<br />
B1<br />
B2<br />
B3<br />
B4<br />
B5<br />
B6<br />
B7<br />
B8<br />
B9<br />
BA<br />
BB<br />
BC<br />
BD<br />
BE<br />
BF<br />
260<br />
261<br />
262<br />
263<br />
264<br />
265<br />
266<br />
267<br />
270<br />
271<br />
272<br />
273<br />
274<br />
275<br />
276<br />
277<br />
10110000<br />
10110001<br />
10110010<br />
10110011<br />
10110100<br />
10110101<br />
10110110<br />
10110111<br />
10111000<br />
10111001<br />
10111010<br />
10111011<br />
10111100<br />
10111101<br />
10111110<br />
10111111
Decimal to Hexadecimal Conversion<br />
Dec Hex Oct Bin<br />
Dec Hex Oct Bin<br />
Dec Hex Oct Bin<br />
192<br />
193<br />
194<br />
195<br />
196<br />
197<br />
198<br />
199<br />
200<br />
201<br />
202<br />
203<br />
204<br />
205<br />
206<br />
207<br />
C0<br />
C1<br />
C2<br />
C3<br />
C4<br />
C5<br />
C6<br />
C7<br />
C8<br />
C9<br />
CA<br />
CB<br />
CC<br />
CD<br />
CE<br />
CF<br />
300<br />
301<br />
302<br />
303<br />
304<br />
305<br />
306<br />
307<br />
310<br />
311<br />
312<br />
313<br />
314<br />
315<br />
316<br />
317<br />
11000000<br />
11000001<br />
11000010<br />
11000011<br />
11000100<br />
11000101<br />
11000110<br />
11000111<br />
11001000<br />
11001001<br />
11001010<br />
11001011<br />
11001100<br />
11001101<br />
11001110<br />
11001111<br />
208<br />
209<br />
210<br />
211<br />
212<br />
213<br />
214<br />
215<br />
216<br />
217<br />
218<br />
219<br />
220<br />
221<br />
222<br />
223<br />
D0<br />
D1<br />
D2<br />
D3<br />
D4<br />
D5<br />
D6<br />
D7<br />
D8<br />
D9<br />
DA<br />
DB<br />
DC<br />
DD<br />
DE<br />
DF<br />
320<br />
321<br />
322<br />
323<br />
324<br />
325<br />
326<br />
327<br />
330<br />
331<br />
332<br />
333<br />
334<br />
335<br />
336<br />
337<br />
11010000<br />
11010001<br />
11010010<br />
11010011<br />
11010100<br />
11010101<br />
11010110<br />
11010111<br />
11011000<br />
11011001<br />
11011010<br />
11011011<br />
11011100<br />
11011101<br />
11011110<br />
11011111<br />
224<br />
225<br />
226<br />
227<br />
228<br />
229<br />
230<br />
231<br />
232<br />
233<br />
234<br />
235<br />
236<br />
237<br />
238<br />
239<br />
E0<br />
E1<br />
E2<br />
E3<br />
E4<br />
E5<br />
E6<br />
E7<br />
E8<br />
E9<br />
EA<br />
EB<br />
EC<br />
ED<br />
EE<br />
EF<br />
340<br />
341<br />
342<br />
343<br />
344<br />
345<br />
346<br />
347<br />
350<br />
351<br />
352<br />
353<br />
354<br />
355<br />
356<br />
357<br />
11100000<br />
11100001<br />
11100010<br />
11100011<br />
11100100<br />
11100101<br />
11100110<br />
11100111<br />
11101000<br />
11101001<br />
11101010<br />
11101011<br />
11101100<br />
11101101<br />
11101110<br />
11101111<br />
Dec Hex Oct Bin<br />
240<br />
241<br />
242<br />
243<br />
244<br />
245<br />
246<br />
247<br />
248<br />
249<br />
250<br />
251<br />
252<br />
253<br />
254<br />
255<br />
F0<br />
F1<br />
F2<br />
F3<br />
F4<br />
F5<br />
F6<br />
F7<br />
F8<br />
F9<br />
FA<br />
FB<br />
FC<br />
FD<br />
FE<br />
FF<br />
360<br />
361<br />
362<br />
363<br />
364<br />
365<br />
366<br />
367<br />
370<br />
371<br />
372<br />
373<br />
374<br />
375<br />
376<br />
377<br />
11110000<br />
11110001<br />
11110010<br />
11110011<br />
11110100<br />
11110101<br />
11110110<br />
11110111<br />
11111000<br />
11111001<br />
11111010<br />
11111011<br />
11111100<br />
11111101<br />
11111110<br />
11111111<br />
Page 140 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
DCC Function Keys<br />
Function Key<br />
F0<br />
F1<br />
F2<br />
F3<br />
F4<br />
F5<br />
F6<br />
F7<br />
F8<br />
F9<br />
F10<br />
F11<br />
F12<br />
Description<br />
Front/Rear Lighting(Dynamo On/Off)<br />
Bell<br />
Whistle<br />
Not Moving: Arm Coil Uncouple<br />
Moving: Plays Coil Couple<br />
Air Pump<br />
Not Moving: Water Fill<br />
Moving: Increase Chuff Magnitude<br />
Not Moving: Blow Down<br />
Moving: Decrease Chuff Magnitude<br />
L1 Control<br />
Double Press: System Volume Up or Down<br />
Single Press: All Sounds Muted Except Horn/Bell<br />
Startup or Shutdown<br />
Shovel Coal<br />
Water Injector<br />
Throttle Stop Zero: Brake Set<br />
Throttle Stop One: Brake Release<br />
Page 141 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00
DCMaster Control<br />
Key<br />
Bell<br />
Horn<br />
Aux<br />
Vol<br />
Bell<br />
Horn<br />
Description<br />
AUX Function Select:<br />
Air Pump<br />
Coupler Sound Effects<br />
Front/Rear Light Control<br />
L1 Light Control<br />
Double Press: System Volume Up or Down<br />
Single Press: All Sounds Muted Except Horn/Bell<br />
Page 142 of 142 | BLI BLUELINE STEAM TECHNICAL REFERENCE MANUAL V 1.00